SMC Corporation of America
Elite Part Number Search
Search Results "AV5000-F06-5YZ-A"

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)

Body Size: 50, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 5000, Port Thread: F (G), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Flow Direction: Left to Right

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: Standard, Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard

Body Size: 50, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 5000, Port Thread: F (G), Port Size: 06 (3/4), Option: None, Voltage: 2 (200 VAC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Flow Direction: Left to Right

Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. OSHA compliant, lockable soft start valve, Large effective area, Low power consumption, Modular design  VALVE, SOFT START LOCKOUT. SOFT START-UP VALVE. 1.55000 lb. 241.

Body Size: 4000, Thread: NPT, Port Size: 1/2, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units

Body Size: 4000, Thread: NPT, Port Size: 1/2, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units

Body Size: 2000, Thread: NPT, Port Size: 1/4, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units

Body Size: 3000, Thread: NPT, Port Size: 3/8, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units

Body Size: 3000, Thread: NPT, Port Size: 3/8, Option: Round Type Pressure Gauge w/Limit Indicator, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units

Body Size: 4000, Thread: NPT, Port Size: 1/2, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units

Body Size: 3000, Thread: NPT, Port Size: 3/8, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units

Body Size: 4000, Thread: N (NPT), Port Size: 04 (1/2), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)

Body Size: 4000, Thread: N (NPT), Port Size: 04 (1/2), Option: S (Silencer), Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)