Size: 40 (1/2), Thread: F (G), Port Size: 04 (1/2), Accessory: None, Option 1: 10 (1000cm³ Tank w/Switch Lower Limit ON)
Body Size: 04 Standard, Elbow: 2, Control Type: Meter-out, Thread Type: R, Port Size: 1/2, Applicable Tubing O.D: ø12, Sealant: w/Sealant
Body Size: 04 Standard, Elbow: 2, Control Type: Meter-out, Thread Type: R, Port Size: 1/2, Applicable Tubing O.D: ø10, Sealant: w/Sealant
Series: VFA3000, Manifold: VFA1000 P,R Port Size: 1/8; VFA3000 P,R Port Size: 1/4, Stations: 04, Type: Common Exhaust, Thread: NPT
Model: Union Y, Plug-in Y, Branch, Applicable Tube OD: Ø12, Port Size Applicable Tube: 04 [R(PT) 1/2], Sealant: Sealant, Color Option: -
Model: Union Y, Plug-in Y, Branch, Applicable Tube OD: Ø10, Port Size Applicable Tube: 04 [R(PT) 1/2], Sealant: Sealant, Color Option: -
Size: No.2, Orifice: 10mm, Style: Normally Closed, Option: For Oil -- Seal: FKM, Body: Brass, Port Size: 04 [1/2 (15A)], Thread: NPTF, Bracket: -
Stations: 04 Stations, Port Size: ø6 One-touch Fitting, Cable Length: 2 [Lead Wire (25 Cores) 3.0 m Lead Wire], Option 1: -, Option 2: -
Stations: 04 Stations, Port Size: ø4 One-touch Fitting, Cable Length: 2 [Lead Wire (25 Cores) 3.0 m Lead Wire], Option 1: -, Option 2: -
Stations: 04 Stations, Port Size: ø6 One-touch Fitting, Cable Length: 0 [Lead Wire (25 Cores) 0.6 m Lead Wire], Option 1: -, Option 2: -
Series: Class 4, Coil Voltage: 110VAC 50/60HZ, Electrical Entry: Conduit Terminal, Orifice: ø10mm, Port Size: 04 [1/2 (15A)], Thread: NPT, Material: -, Option: -
Series: Class 3, Coil Voltage: 110VAC 50/60HZ, Electrical Entry: Conduit Terminal, Orifice: ø10mm, Port Size: 04 [1/2 (15A)], Thread: NPT, Material: -, Option: -
Indicator: S, Control Method: E (Meter-out), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread: R, Port Size: M3 (M3 x 0.5)
Stations: 8 Stations, Port Size: 04 (1/2), Thread: N (NPT), SI Unit: SQA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit COM: N (-COM)
For plug-in type manifolds:
Since there is a spare connector inside the manifold, the parts to be ordered differ depending on whether there are 4 pins or more or less than 4 pins remaining in each wiring kit.
The max. number of stations that can be increased varies depending on the wiring kit.
When a “D” is inserted between the “C” and “U” in the part number, this indicates that there is a built-in magnet (e.g., CDU10-20D). Note that for bore sizes ø16 and larger with a built-in magnet, the overall length dimensions (the S and Z dimensions) will extend beyond the standard dimensions (without magnet). Please refer to the catalog for details.
Note 1) For CDU/CDUK single acting
Their usage depends on the load.
The 2-wire type has a large leakage current, and there are cases where the switch OFF state cannot be recognized when used in combination with a PLC.
The 3-wire type has separate power supply and signal lines, and NPN or PNP output must be selected according to the input specifications.
Leakage current:
3-wire type: 100 μA or less for 24 VDC
The main output signals are as follows.
OUT signal: When the DRIVE input is turned OFF, the current operation (operation completed) step no. is output. It is not synchronized with the operation completion. Use this function to check the step data of the current operation (operation completed).
INP signal: This signal is output when it reaches the positioning range. Use this function
See the figure below. The servo is turned OFF after the actuator stops and the lock is activated.
The lifting force of a vacuum pad can be obtained from the calculation formula as well as from the theoretical lifting force table.
Calculation formula:
W = P x S x 0.1 x 1/t
(W: Lifting force(N), P: Vacuum pressure(Kpa), S: Area of the pad(cm²), and t: Safety factor of 4 or more for horizontal lifting and 8 or more for vertical lifting)
Theoretical lifting force table:
The