SMC Corporation of America
Elite Part Number Search
Search Results "VS3115-025GP-T"

Fluoropolymer Piping Equipment LQ1/LQ3/LVN/LQHB/T Series LVC LVA LVH LVD LVQ LVP LVW LQ1 LQ1 Fluoropolymer Fittings Hyper Fittings LQ1 Series Fluoropolymer Fittings Hyper Fittings/ Flare Type LQ3 Series LQ3 LQ3 LVN LVN LQHB LQHB TL TIL TL TIL TLM TILM TLM TILM New PFA New PFA New PFA New PFA TD TID TD TID TH TIH TH TIH Needle Valve LVN Series Bore Through Connector LQHB Series Fluoropolymer

Complement: Polyurethane tubing (Series TU), nylon tubing (Series T), and soft nylon tubing (Series TS) can be used, but the degree of clean performance will be reduced. Construction Standard type Double acting type N.C. type N.O. type w e q q e w q e w y t r A B A B With flow rate adjustment u Component Parts No.

Press the knob to lock the setting. t Trigger Switch to turn on and off static neutralization y One-touch fitting Supply port of compressed air t i u Power supply connector Connector for power supply, F.G., and external switch inputs i Lighting LED Illuminate the object during static neutralization * Inside of the slide cover y u Description of LED Indicators LED Indicators w q e No.

0 o i u y t r e w q No. Description Type Contents Power supply indicator Illuminates when power is supplied. Flashes when the supply voltage is irregular. 1 LED (Dark green) Sensor indicator 2 Illuminates when the feedback sensor, autobalance sensor [high-precision type], or autobalance sensor [body-mounting type] is connected.

Clip Approx. 80 to 90 or b Auto switch mounting band Fig. 1-5 Fig. 1-4 a Switch holder Enlarged view of clip M2.5 set screw (Accessory) e i Auto switch r Reinforcing plates w q y u c M3 set screw 5.1 or more 0 to 5 t Reinforcing plates M3 set screw Nut M3 set screw Nut The end of the set screw is protruding.

View port View port G1/2 Refer to page 529 for Microswitch for differential pressure indication switch. 504 A Suction Filter with Case FH99 Series Dimensions Differential pressure indication switch Blanking cap Differential pressure indicator 8 x T 16 (65) N I (34) E F U OUT X H O 62 B U U R S 4 x K OUT OUT Q P IN Differential pressure indicator Differential pressure indication switch G

If frequent cleaning will be necessary, it can be suspended from the top panel of the tank. t If a fluid switch (built-in lead switch) or the like is used, it should be installed in a location where it will not be affected by magnetism from the separator. (Refer to the technical data sheet (FGX-TDT011) for information on magnetic fields.) Maintenance q Clean the separator regularly.

Signal contents HEBC002-WA10 RS-485 T/R (A) RS-485 T/R (B) Unused Unused Unused Unused HEBC002-WB10 Unused RS-232C RX RS-232C TX Unused RS-232C SG Unused AWG14 Male connector 1 2 3 4 5 6-9 Signal contents 100 to 240 VAC (L) 100 to 240 VAC (N) PE Male connector Hirose Electric Co., Ltd.: CDA-15P Holding screw M2.6 Black 1 Black 2 Nanaboshi Electric Mfg. Co., Ltd.

Voltage R With an earth leakage breaker Symbol Voltage 23 Single-phase 230 VAC (60 Hz) 11 Single-phase 115 VAC (60 Hz)*1 T With a terminal block for operating, error, and remote operation signals V With a timer controlled solenoid valve type auto drain [The maximum operating pressure is 232 psi (1.6 MPa).] *1 IDFB60 only When multiple options are combined, indicate symbols in alphabetical

500 600 700 800 900 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1096 Direct Operated Precision Regulator Series ARP20 to ARP40 10211021Direct Operated Precision Regulator with Backflow Function Series ARP20K to ARP40K 10211021Dimensions 2 x P1 Port size A Pressure gauge (Option) Q C OUT IN K P2 Pressure gauge port size V B Tubing support 6/4 R Bleed port F S U D N Bracket (Option) J M T

N K W N S + Stroke F F NA R ZZ + Stroke 43 35 29 22 20.5 27.8 D Model Port size K NN B L MM x J N NA H 16 15 10 I 46 36 30 NB 19 17 17 T S 11 9 8 G ZZ 10 8 8 R 60 50 50 W 16 16 13 F 40 40 30 X 12-REA40 12-REA32 12-REA25 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 70 60 46 M26 x 1.5 M26 x 1.5 M32 x 2.0 21 17 15 50 40 34 19 15 13 150 124 111 182 156 137 92 80 70 M5 x 0.8 x 8 M6 x 1.0 x8 M6

Flat ribbon cable (20P) kit, without cable F kit U side D side 16 stations 1 to 12 stations 24 D side D-sub connector kit P kit Note 1) 1 to 12 stations 24 D side 16 stations 26P 20P 1 to 9 stations 18 Flat ribbon cable connector kit J kit Flat ribbon cable (20P) PC wiring system compatible JD0 D side 1 to 8 stations 16 stations 16 Flat ribbon cable (20P) (PC Wiring System compatible) T

Description AMR3000 1349161A 13579 135711A 135011 G75 135714 AMR4000 131515A 135511 13154A 131514 G90 635327 AMR5000 131515A 13589 135811A 131613 G100 635327 AMR6000 131614A 13569 135614-1A 135413 G115 63555 Diaphragm ass'y Element (1) Body Housing Bowl Bonnet Aluminum alloy Aluminum alloy Aluminum alloy Brass Stainless steel NBR Fiber q w e r t y u i o !

Handle 1348102#1 ADC POM e Bonnet Piston assembly 1348104A r POM POM, NBR Valve 1348105 t Brass, NBR Valve spring 1348109 y Stainless steel 1348108 (For 0.85 MPa) Steel wire Adjusting spring u 1348108-1 (For 0.3 MPa) Dimensions Panel cutout dimensions 26 R2.5 SUP OUT SMC K C O P A A L U S H 12 37 54 25 1.6 (Max. thickness 4.5) 44 79.5 (When regulating pressure = 82) 5.4 10 31.5 OUT OUT 35

Description Material Part no. t y u i 1429138 142964 9 x 7 x 1 M-5G1 Valve seat U seal O-ring Gasket Brass HNBR NBR PVC 15-9-29

Metric size Inch size M D1 Model number Piping thread 6 1/4 3/8 1/2 10 12 8 Pilot port (5/16) ASP330F-U01-X352 1/8 Uni-fit G 1/8 L1 T ASP430F-U02-X352 1/4 Uni-fit G 1/4 ASP530F-U03-X352 3/8 Uni-fit G 3/8 D2 ASP630F-U04-X352 1/2 Uni-fit G 1/2 H L2 Note) Additional models are possible (i.e. thread form/tubing size combinations), please contact L4 your SMC representative for availability.

In the energy saving operation mode, changing the set dew point can save more energy. 5% reduced 5% reduced Conditions Ambient temperature: 90F (32C) r 40% reduced 40% reduced Inlet air temperature: 104F (40C) Double energy saving function series Power consumption Inlet air pressure: 102 psi (0.7 MPa) t y u 61% reduced 61% reduced Power supply frequency: 60 Hz Power supply voltage: 200 V

Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 3 Construction w r y t u !2 e !1 No. q w e r t y u i o !0 !1 !

hexagon nuts on panel nuts up and down in two locations enables user to mount or remove it depending upon the situation. 3.2 1 8" 4 6 8 10 12 5 32 " 3 16 " 1 4" 5 16 " 3 8" 1 2" AS AS1001F AS-FE AS2001F AS2051F Panel KE AS3001F AS4001F AS-FG Specifications Panel nut AS-FP Hexagon nut Air Fluid AS-FM 1.5 MPa Proof pressure 1 MPa Max. operating pressure AS-D 0.1 MPa Min. operating pressure AS-T

rate L/min (ANR) AS-F TMH ASD AS AS Number of needle rotations Number of needle rotations Number of needle rotations AS-FE AS3000 AS4000 AS5000 Inlet pressure: 0.5 MPa KE Inlet pressure: 0.5 MPa Flow rate L/min (ANR) Inlet pressure: 0.5 MPa Flow rate L/min (ANR) AS-FG Flow rate L/min (ANR) AS-FP AS-FM AS-D Number of needle rotations Number of needle rotations Number of needle rotations AS-T