The cancel cap holds the lever horizontally allowing a pallet to pass.
Applicable cable O.D. 6 to 8 Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) E Pilot port 12(P1), 10(P2) Port size: refer to table below C K (External pilot solenoid) P1 P2 J J B (Air operated) D 4 x 2 x 18 mouting hole 32 H F A Applicable flange Port 1, 2 Pilot port 12(P1), 10(P2) A Model B C D E F H J K Note) VNC5-32F VNC6-40F VNC7-50F 1 8 1 4 1 4 32 40
140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator
Flow Characteristics/Weight 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Flow characteristics Weight (kg) Port size Model Type of actuation C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 4.5 5.1 5.6 4.5 5.1 5.6 4.0 4.5 5.0 4.2 (4.0) 4.8 (4.5) 5.5 (4.8) 0.33 0.28 0.28 0.33 0.28 0.28 0.29 0.23 0.23 0.29 (0.28) 0.24 (0.27) 0.23 (0.30) 16 19 21 16 19 21 15 18
Type 30 Passage pipe assembly VVCW20 2 C 1 01 Types 10, 20 VVDW 2 0 6A Material Brass Stainless steel C S Thread type Materials Series Symbol Nil A G H Rc G NPT Nil F N Pipe material 1 2 10 20 Seal material NBR FKM NBR FKM Stations Brass For 2 stations For 3 stations OUT port size 1 2 Stainless steel Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Type 30 VVCW20 6A Materials Symbol Nil A G H Seal
Detaching To detach a socket from a connector, pull out the lead wire while pressing the sockets hook with a stick having a thin tip (about 1 mm). If the socket will be used again, first spread the hook outward.
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262 0-04 only) 2-M5 x 0.8 depth 8 Dimension of view from A Pilot port Port size P Rc , With bracket E Port size View from A Model A B C D VXA22 52 60 02 03 VXA226 -04 2 0 1 4 3 8 22 28 11 14.5 67 73 77 83 27 30 1 2 Fixing with thread is also possible
High sfength construction pre\rents damage to threads from a side directional shock. Symbol il] Specifications lrar operrting prsurst45PSl(l0,zkgt/cm,) lkfto rductidts-'lgdB or more Operating trnpGratur range-4o , 1 40'F (5 60'C) Flour Gharacteristics Model Model Port size (NPT) Ettective orifice mm2 (Cv) \ leighl lbs. (g) Dimensions In.
Using SMC speed controls with built in one-touch fittings minimizes installation time, reduces mounting height and enables a more compact machine design. These speed controls allow the body to be rotated to facilitate simple installation.
The VM series is a mechanical, poppet valve. Their compact size requires little mounting space. The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 19mm 2 (1.0), Fluid temperature: -5° to 60°C (no freezing), Port size (nominal size): Rc(PT) 1/4 (8A) MECHANICAL VALVE.
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is made
Series AL modular style lubricator provides accurate lubrication of downstream equipment. The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment. Atomizes lubricant into fine particles at uniform rate, Drip rate easily monitored with sight dome, Can be refilled under pressure, High-response time
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is made
The ARP is a modular style, direct operated precision regulator. A locking adjustment knob allows the pressure to be set, and then locked to prevent accidental setting changes. The ARP20/30/40 series is available with a back flow function that exhausts the air pressure in the outlet side reliably and quickly.
The ARP is a modular style, direct operated precision regulator. A locking adjustment knob allows the pressure to be set, and then locked to prevent accidental setting changes. The ARP20/30/40 series is available with a back flow function that exhausts the air pressure in the outlet side reliably and quickly.
SMC series AS*002F, in-line type, compact speed controllers with built in one-touch fittings minimize installation time, reduce mounting height, and enable a more compact machine design. These speed controls can be mounted in 4 variations (direct mounting, L-bracket mounting, DIN rail mounting and holder mounting).
The ARP is a modular style, direct operated precision regulator. A locking adjustment knob allows the pressure to be set, and then locked to prevent accidental setting changes. The ARP20/30/40 series is available with a back flow function that exhausts the air pressure in the outlet side reliably and quickly.
Series VMG has a large effective area of 0.05in? (30mm?), without nozzle. Pressure loss is 0.725psi (0.005MPa) or less when nozzle bore size 2.5mm is used.? Piping direction is optional from the top or bottom.??
Series VMG has a large effective area of 0.05in? (30mm?), without nozzle. Pressure loss is 0.725psi (0.005MPa) or less when nozzle bore size 2.5mm is used.? Piping direction is optional from the top or bottom.??