[Features] · Flow ratio: 100:1. · A single unit can measure a wide range of flow rates. · Improved drainage and resistance to foreign matter. · 75% reduction in pressure loss. · Through-bore construction. · Supports 3-color, 2-screen display and has good visibility. · Smallest settable increment: 2 L/min. · Grease-free. · Display rotates 90° and can be reversed. · Visualization with a digital

The double vane style offered on the 90° and 100° rotation allows twice the torque of the single vane. Bearings are used throughout the series to support thrust and radial loads. In addition, rubber bumpers are used internally (except for size 10) making this series highly reliable.

Double vane type is standardized for 90 and 100 degrees.   Two shaft options available ; Port locations modified ; RoHS compliant ; Mounting position of the auto switch can be set freely

Double vane type is standardized for 90 and 100 degrees. Two shaft options available; Port locations modified; RoHS compliant; Mounting position of the auto switch can be set freely

The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility. Rotary table w/external shock absorber; Four bore sizes available; High precision or basic type available; 90° and 180° rotation available; Auto switch capable

The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility. Low speed rotary table; Rotation time adjustment range: 1 to 5 (s/90°); Dimensions compatible with the MSQ series; Smooth motion without stick-slip phenomenon

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: 1-5V or 4-20mA; Accuracy: ±3% F.S. ; Repeatability: ±2% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100, 50-250; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2 (flow range dependent); Temperature rating: 0-90°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; PORT sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature range (°C): 0 to 90; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature range (°C): 0 to 90; Output options: NPN or PNP (switch); 1-5V or 4-20mA; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.

The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.

Double vane type is standardized for 90 and 100 degrees.  Possible to move plate mounting position; Vertical and lateral mounting; Auto switch capable; RoHS compliant

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Piping sizes (Rc, NPT, or G): 3/8, 1/2, 3/4, 1; Temperature range (°C): 0 to 90; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.; Accuracy (temperature): ±5% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature range (°C): 0 to 90; Output options: NPN or PNP (switch); 1-5V or 4-20mA; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.