The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

0.12% (Full span)/C0 to 50C (No condensation)Equivalent to IP65 ?Built-in One-touch fittingsz, x, c: ?4z, x, c: ?5/32andquot;z, c: ?6, x: ?4z, c: ?1/4andquot;, x: ?5/32andquot;100 g or less (without option)

voltageAllowable Note 5)voltage fluctuationType of coil insulationPower consump- tion (When rated voltageis at 24 V)Coil switching noise Note 5)Body portedLVM11Diaphragm type direct operated poppetN.C.2Air, Water, Pure water, Diluent, Cleaning solvent0 to 0.25 MPa1.5 mm10 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa0 to 50C0 to 50C

voltageAllowable Note 5)voltage fluctuationType of coil insulationPower consump- tion (When rated voltageis at 24 V)Coil switching noise Note 5)Body portedLVM11Diaphragm type direct operated poppetN.C.2Air, Water, Pure water, Diluent, Cleaning solvent0 to 0.25 MPa1.5 mm10 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa0 to 50C0 to 50C

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, CONNECTOR ASSY, VALVE

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient and fluid temperature: -10 to 50C

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50C, VQZ1000 NO SIZE RATING, VALVE,

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient fluid temperature: -10 to 50C

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient fluid temperature: -10 to 50C

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient fluid temperature: -10 to 50C

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient fluid temperature: -10 to 50C

range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient fluid temperature: -10 to 50C

OUT1, OUT2: OrangeAnti-chattering, Zero-out, Key lock function, Auto-preset, Auto-shift, Unit display switching, Power-saving modeIP65Operating: 0 to 50C, Stored: ?

The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient and fluid temperature: -10 to 50C

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BASE MT