SOL.A SOL.B SOL.A SOL.B SOL.A SOL.B () (+) 1A VQ0 1 station{ () (+) 1B () (+) 2A 2 stations{ VQ4 () (+) 2B () (+) 3A 3 stations{ () (+) 3B VQ5 () (+) 4A 4 stations{ () (+) 4B VQZ () (+) 5A 5 stations{ () (+) 5B 2-G 3/4 Electrical entry () (+) 6A VQD 6 stations{ () (+) 6B () (+) The total number of stations is tabulated starting from station one on the D side. 7A 7 stations{ () (+) 7B () (+) 8A
terminal Rc Nil G F NPT N Light/Surge voltage suppressor NPTF T Nil Z None With light/surge voltage suppressor Port size 04 06 10 1 2 3 4 1 *Specifications and dimensions for the 90-series are the same as standard products. 9 3 Port Solenoid Valve Direct Operated Poppet Type Rubber Seal 90-VT317 Series How to Order 317 02 5 D Z V T 90 Series compatible with secondary batteries Port size 02 (8A
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring is double wiring (connected to SOL. a and SOL. b) regardless of number
SX3000-64-8A M3 x 26 (Flat nickel plated) SX5000-57-5 6 SY3000-23-4 Round head combination screw 7 8 SX3000-57-4 VZ1000-11-1Gasket DIN rail Refer to page 1.2-107.
base Sub-plate Type 10-SS5YJ5-40-Q Type 10-SS5YJ5-41-Q Type 10-SS5YJ5-42-Q Type 10-SS5YJ5-43-Q Type 10-SS5YJ5-41P Type 10-SS5YJ5-43P Type 10-SS5YJ5-41SA Type 10-SS5YJ5-42SA Type 10-SS5YJ5-43SA Type 10-SS5YJ5-41P-Q Type 10-SS5YJ5-43P-Q Type 10-SS5YJ5-41SA-Q Type 10-SS5YJ5-42SA-Q Type 10-SS5YJ5-43SA-Q Blanking Plate Assembly SYJ5000-21-5A SYJ5000-21-7A SYJ5000-21-6A SYJ5000-21-8A
Max. voltage (with no load): 30Vrms (42.4V peak) or less Max. current: 8A or less (including shorts), and When controlled by a circuit protector (fuse, etc.) with the following rating No-load voltage (V peak) 0 to 20 [V] Max. current rating 5.0 100 Over 20 [V] to 30 [V] Peak voltage value (2) A circuit (class 2 circuit) with maximum 30Vrms (42.4V peak) or less, and a power supply consisting
SX3000-64-8A M3 x 26, Matt nickel plated SX5000-57-6 6 SY3000-23-4 7 8 SX3000-57-4 VZ1000-11-1-l Refer to page 276.
.1 SD time-out error/serial communication 8A 0 0 0 0 time-out error/Modbus RTU 8A.2 Modbus RTU communication time-out error SD communication time-out error 8D.1 CC-Link IE communication error 1 SD 8D.2 CC-Link IE communication error 2 SD 8D.3 Master station setting error 1 DB 8D.5 Master station setting error 2 DB 8D.6 CC-Link IE communication error 8D CC-Link IE 3 SD communication error
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Thread type Valve option VT Nil F Rc G NPT NPTF Nil Standard type E Continuous duty type N T VP Y Energy-saving type (2 W DC) V For vacuum VG W Energy-saving type, For vacuum Port size Nil VP 02 (6A) 01 Without port (For manifold) Option 1 8 (8A)
0.4 0.2 0.45 0.2 0.15 VX2130-01 4.5 0.61 11 Oil 2 1.5 2 1.5 1 1.5 1.5 VX2110-02 2 0.17 3 1.1 0.6 0.9 0.5 1 0.5 0.5 VX2120-02 3 0.33 6 Air 5 2 1.5 1.7 1.5 1 1.2 1.2 VX2220-02 3 0.33 6 3 3 3 2.5 3 1.7 2 VX2320-02 3 0.33 6 0.45 0.2 0.4 0.2 0.45 0.2 0.15 VX2130-02 4.5 0.61 11 0.75 0.35 0.6 0.35 0.75 0.35 0.3 VX2230-02 4.5 0.61 11 1/4 Steam 1 0.9 0.85 0.9 1 0.55 0.85 VX2330-02 4.5 0.61 11 (8A
D-Y7NWV D-Y7BW D-Y7BWV Lead Wire Entry In-line Perpendicular In-line Perpendicular Wiring Method 3 Wire 3 Wire 2 Wire 2 Wire Application PLC 25VDC PLC Power Source 5.12.24VDC (4.5-28VDC) Current Consumption 10mA max 10mA max Load Voltage 28VDC max 28VDC max 24VDC (10-28VDC) 24VDC (10-28VDC) Load Current 40mA max 40mA max 5-40mA 5-40mA Internal Voltage Drop 1.5V max 1.5V max 4V max 4V max (8A