Single acting, spring return/extend, valve mounted; Applicable bores (mm): 20, 25, 32, 40; Standard strokes (mm): 25, 50, 75, 100, 125, 150, 200, 250; Auto switch capable
Body sizes: 8, 16, 25 ; Strokes: 30, 50, 75, 100, 125, 150 (availability dependent on size) ; Positioning repeatability: ±0.05 ; Motor can be mounted internally with a right or left table, or in-line ; Motor types: high load step motor or high speed servo motor
Body sizes: 8, 16, 25 ; Strokes: 50, 75, 100, 150 (availability dependent on size) ; Positioning repeatability: ±0.05 ; Motor can be mounted internally with a right or left table, or in-line ; Motor types: high load step motor or high speed servo motor
Bore sizes: 20, 25, 32, 40; Standard stroke: 25, 50, 75, 100, 125, 150, 250; Easy fine adjustment of auto switch position; Female rod end available as standard
Body size: 25; Maximum work load: 5 kg (horizontal or vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 30, 50, 75, 100, 125, 150mm; Positioning repeatability: ±0.05mm
Body size: 8, 16, 25; Strokes: 50, 75, 100 or 150mm; Maximum work load: 12 kg (horizontal, 20 kg (vertical)); Maximum pushing force: 420 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm
Body size: 8, 16, 25; Strokes: 50, 75, 100 or 150mm; Maximum work load: 12 kg (horizontal, 20 kg (vertical)); Maximum pushing force: 420 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm
The refrigeration circuit is air cooled by a single large fan, with a low sound level of 70~75 dB(A) depending on capacity. Alternately, facility water cooled versions are also available. Set tempertures are PID controlled, while the system is monitored for 42 alarms.
The refrigeration circuit is air cooled by a single large fan, with a low sound level of 70~75 dB(A) depending on capacity. Alternately, facility water cooled versions are also available. Set temperatures are PID controlled, while the system is monitored for 42 alarms.
Body size: 25; Maximum work load: 5 kg (horizontal or vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 30, 50, 75, 100, 125, 150mm; Positioning repeatability: ±0.05mm
Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder
Body size: 8, 16, 25; Strokes: 50, 75, 100, or 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 765 N; Maximum speed: 800 mm/s; Maximum accel / decel: 10,000 (horizontal), 5,000 (vertical) mm/s²; Positioning repeatability: ±0.01mm
Body size: 8, 16, 25; Strokes: 50, 75, 100, or 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 765 N; Maximum speed: 800 mm/s; Maximum accel / decel: 10,000 (horizontal), 5,000 (vertical) mm/s²; Positioning repeatability: ±0.01mm
Body sizes: 25, 32, 40; Maximum work load: 75 kg; Maximum speed: 1300 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm, or ±0.02mm (high speed screw lead); Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent)
Body sizes: 25, 32, 40; Maximum work load: 75 kg; Maximum speed: 1300 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm, or ±0.02mm (high speed screw lead); Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent)
Available in 50 and 63 bore sizes. Compiles with NAAMS standard (CKZ5N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightwieght; High clamping force
Available in 50 and 63 sizes. High clamping force; 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightweight
The refrigeration circuit is air cooled by a single large fan, with a low sound level of 70~75 dB(A) depending on capacity. Alternately, facility water cooled versions are also available. Set temperatures are PID controlled, while the system is monitored for 42 alarms.
Available in 50 and 63 bore sizes. The operating time for arm opening angles of 15° to 90° can be set to 0.6 s. Compiles with NAAMS standard (CKZ5N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightwieght; High clamping force
Bore sizes: 40, 63, 100 mm; Stroke lengths: 30, 50, 75, 100; Non-rotating accuracy +/-0.08° for 40 mm bore; Non-rotating accuracy +/-0.06° for 63 mm bore; Non-rotating accuracy +/-0.05° for 100 mm bore; Auto switch capable