The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Simple connection/disconnection, High retaining force, Miniature size, Accepts many styles of plastic tubing, GASKET FOR M3 FITTING, CONNECTORS, M MINI FITTING, 21, M NO SIZE RATING, 0.00185 lb
Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5,
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, ELBOW, AIRLINE EQUIPMENT, AS FLOW CONTROL, 1B, AS OTHER SIZE STANDARD (PT), .00595 lb
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
Series S070 is a super compact direct acting 2/3 port solenoid valve that meets the miniaturization needs of analyzers and semiconductor manufacturing equipment. S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base). Valve width is 7mm. 3 port solenoid valve, direct operated
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, SY100 SOLENOID VALVE, 2A, SY100 NO SIZE RATING, .04400 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, 1B, AS***F OTHER SIZE RATING (PT), .01194 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL 12VDC, VALVE, SY100 SOLENOID VALVE, 2B, SY100 NO SIZE RATING, .02420 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, SY100 SOLENOID VALVE, 2A, SY100 NO SIZE RATING, .05874 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL 110VAC, VALVE, SY100 SOLENOID VALVE, 1A, SY100 OTHER SIZE RATING, .03542 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, SY100 SOLENOID VALVE, 2A, SY100 NO SIZE RATING, .05732 lb
Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5,
9.5 MHS A C 32 M3 x 0.5 Finger opening port M3 x 0.5 Finger closing port MHC MHT 25 25 MHY 3-3 depth 6 +0.02 0 M3 x 0.5 Finger opening port M3 x 0.5 Finger closing port (A, B, C common view) MHW 6-M3 x 0.5 thread depth 6 (A, B, C common view) MRHQ Misc.
M3 x 10 (4 pcs.) 11 14 15 20 740 AHC System Series MA2 How to Order AHC unit AHC unit MA 210 Y M3 N R3 Tool adapter Robot adapter Without robot adapter 8 10 11 14 15 20 Nil S1 R1 R2 R3 R4 R5 Auto hand changer Air gripper for AHC Applicable shaft diameter Transportable mass Transportable mass 3 kg 2 AHC unit Electric specifications Air connection size M3 M3 x 0.5 None N Air gripper for AHC
Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: 0 (w/o Fitting, M3
Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: 0 (w/o Fitting, M3
Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Y (DC Low Wattage Type (0.5W), Power Supply Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 0 (w/o Fitting, M3
Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: 0 (w/o Fitting, M3