Model: Extended Male Elbow, Applicable Tube OD: Ø10, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: Male Run Tee, Applicable Tube OD: Ø10, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: Extended Male Elbow, Applicable Tube OD: Ø6, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: 45°Male Elbow, Applicable Tube OD: Ø12, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: Male Run Tee, Applicable Tube OD: Ø12, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: 45°Male Elbow, Applicable Tube OD: Ø8, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: Extended Male Elbow, Applicable Tube OD: Ø12, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: 45°Male Elbow, Applicable Tube OD: Ø6, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: 45°Male Elbow, Applicable Tube OD: Ø10, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Model: Extended Male Elbow, Applicable Tube OD: Ø8, Port Size Applicable Tube: 03 [R(PT) 3/8], Sealant: Sealant, Color Option: -
Body Size: 3/8 Basis, Body Material: 1 [ADC12 (Aluminum)], Thread: F [G(PF)], Port Size: 03 [3/8 (15A): PA3]
.· Y44-□02-A, 03-A applicable model: AC40□-A.· Y54-□03-A, 04-A applicable model: AC40□-06-A.
Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature