SMC Corporation of America
Elite Part Number Search
Search Results "AL20-F02-C-A"

1396.5 1006 1070 14 5 1000 80 11-LEJS63S-12001556.5 1596.5 1206 1270 16 6 1200 80 11-LEJS63S-15001856.5 1896.5 1506 1570 18 7 1400 180 536 LEJ Series Auto Switch Mounting Auto Switch Mounting Position (C) B (Table center) A [mm] Model Size A B C Operating range LEJS 40 77 80 160 5.5 LEJB 5.0 LEJS 63 83 86 172 7.0 LEJB 6.5 Note) The operating range is a guideline including hysteresis, not

C C C D D D D Body (material: A6063) K C C C C E E E E E E E E KF flange F F F Fn n n n (KF) () Heater (option) Auto switch H H H H J J J J G G G G B B B B A A A A A A A A Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9 8 XL-OMO0001-A 5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions

per branch Power supply for input and controlling GW: Max. 4.1 A (Inside GW unit: 0.1 A, Input unit: 4 A) Power supply for output: Max. 6 A Current for output branch Max. 1.5 A per branch Rated current At 0.75 A per branch: 20 m or less At 1.0 A per branch : 16 m or less At 1.5 A per branch : 10 m or less Branch cable length Input/ output point Input point: Max. 64/ Output point: Max. 64

Table 3-6 RTU mode message frame a) Start b) Device Address c) Function d) Data e) Checksum (CRC) f) End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).

Take safety measures (e.g. mounting protective covers) when workpieces pose a danger of fingers being caught in a gripper, etc. 3. There is a danger of workpieces dropping if there is a decrease in gripping force due to a drop in circuit pressure caused by a power failure, etc.

4 x N through Q F 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 12 5

steel J D I G F E C Thread B A Barb one-touch: M-32F-2, M-04F-2 Applicable tubing (mm) a (O.D. x I.D.) b (O.D.) 3.2 4 2 x 1 .2 Weight g B C D E M A Model M-32F-2 M-04F-2 17.7 18 1 3.7 14 7.5 8.5 2.4 2.9 4 0.9 12.7 Parts list 4 3 2 1 E Material Brass Brass NBR No. 1 2 3 4 Description Sleeve Body Seal Cassette Note Electroless nickel plated Electroless nickel plated D C POM, Stainless steel

DXT060-27A Flow Characteristics/Weight Weight (kg) Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Valve model b Cv Grommet Port size b Cv b Cv C [dm 3/(sbar)] C [dm 3/(sbar)] C [dm 3/(sbar)] C [dm 3/(sbar)] b Cv 0.63 0.30 0.16 0.59 0.30 0.15 0.59 0.32 0.15 0.65 0.30 0.16 0.11 (With bracket: 0.13) 0.66 0.28 0.16 0.60 0.29 0.15 0.61 0.32 0.15 0.66 0.30 0.16 0.34 0.26 0.084

IDX-OM-W026-A / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO4414Pneumatic fluid power General rules and safety requirements

pcs. 9.5 depth of counter bore 7 (mounting hole) A B C D E F G N Part no.

IDX-OM-W023-B / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 )

As a result, it will not be possible to verify it with the vacuum switch. In such a case, it is necessary to use an ejector that is suited to the nozzle and to select a vacuum switch with a favorable hysteresis and precision. 3.

Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E

9e c:o c+o coo c+z cse l-cos 'lncludes Rod Packing. Piston Packing, and Tube Gasket (2) Comoact Guide Cytinder: Series MGQ 0120zs,/MGQM'MGQL A Perspective drawing 4-NN Thrcugh NOTE !

9e c:o c+o coo c+z cse l-cos 'lncludes Rod Packing. Piston Packing, and Tube Gasket (2) Comoact Guide Cytinder: Series MGQ 0120zs,/MGQM'MGQL A Perspective drawing 4-NN Thrcugh NOTE !

Rc1/4 Rc3/8 Bottom Note) When equipped with control unit, 1 or 2 stations are used for mounting. 6 Series VQ7-6 DIN Connector Type VV71-100 80 2n-Rc1/4, 3/8 100 80 9 37 9 23 14 U side 15 R4.5 Manual override Indicator light R4.5 53.5 P=43 9 9 53.5 P=43 20 9 23 38 B B B B B B B B B SMC SMC SMC A PA PA PA PA A A A A B A L1 L2 L2 L1 B A B SMC A B A 4n-Rc1/4, 3/8 (ports A, B) PA L side R side

B Auto switch a b d c Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Proper Mounting Position (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper Mounting Position (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-M9 type D-F9 W type 2 6 5 8 12 11 In order

Manual override (locking lever type) A M 300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I

Paddle short A: Paddle short B: Paddle middle B: Paddle middle Port size C: Paddle long C: Paddle long Port size ISA2 IS ZSM PF2 Dimensions Part no.