BP1020 15 to 200 psig (0.1 to 1.4 MPa) BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) Operating pressure Select compatible materials of construction for the gas Gas Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv 15 psig (0.105 MPa) 30 psig (0.2 MPa) 45
Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Mass (g) Model IN OUT OUT EXH AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 M5 x 0.8 2 2.8 25 1 8 4 5.8 45 1 8 25 25 110 1 4 35 40 105 1 4 40 42 215 8 3 60 70 205 1 2 105 115 690 3 4
Regulating pressure range AMR Ambient and fluid temperature Fluid Cracking pressure (Valve) Construction ARM ARM ARP Port Size/Weight IR-A Model Piping Port size Weight (g) IN side OUT side Total weight (n: stations) Regulator (Except manifold) IR Small size pressure gauge 15 Backflow function available on the standard model Space-saving (80 x n) + 23 (79 x n) + 25 (188 x n) + 43 (187 x n) + 45
Refer to page 959. 1500 1500 1500 1500 1000 Max. collision speed (mm/s) 80 45 25 70 80 Max. operating frequency(cycle/min) 1.96 6.86 8.34 4.22 Extended 1.96 Spring force (N) 4.22 15.98 20.50 6.86 Retracted 3.83 5 to 60 Operating temperature range (C) The shock absorber service life is different from that of the MY1B cylinder depending on operating conditions.
Shock Absorber Specifications RB 1412 RB 1007 RB 2015 Shock Absorber Model for L and H Units Model Bore size (mm) 25 Stroke adjustment unit Type Max. absorbed energy (J) 58.8 19.6 5.9 32 40 15 12 7 Stroke absorption (mm) RB1007 L RB1412 Standard (Shock absorber/RB series) 1500 1500 1500 Max. collision speed (mm/s) RB1412 H RB2015 25 45 70 Max. operating frequency (cycle/min) RJ1007H L RJ1412H
Shock Absorber Specifications Shock Absorbers for L Unit RB 0806 RB 1007 RB 1412 RB 2015 Model Stroke adjustment unit Standard (Shock absorber/RB series) Bore size (mm) 2.9 6 5.9 7 19.6 12 58.8 15 Type 20 Max. energy absorption (J) Stroke absorption (mm) Max. collision speed (mm/s) 16 25 63 32 40 50 1500 L RB0806 RB1007 RB1412 RB2015 80 1.96 4.22 70 4.22 6.86 45 6.86 15.98 25 8.34 20.50 Max
Construction Relief style Port size/Weight Model Porting Port size Weight lb (g) Small Size Pressure Gauge 15mm Reverse flow function available on the standard model IN OUT Total weight (n: stations) Regulator (Except manifold) 1 8 1 8 (80 X n) + 23 Common IN .13 (57) NARM1000 1 8 1 8 (79 X n) + 25 Individual IN Common IN 1 4 1 8 (188 X n) + 43 NARM2000 .3 (136) Individual IN 1 8 1 8 (187 X n) + 45
Automatically operated type Specifications Model Automatically operated type PA310 PA320 PA510 PA520 JIS Symbol Main fluid suction 1/2, 3/4 3/8 discharge port FLUID OUT AIR SUP Port size Pilot air supply/ exhaust port 1/4 AIR EXH FLUID IN ADC12 SCS14 SCS14 ADC12 Body wetted areas Material Diaphragm PTFE, NBR Automatically operated type Check valve PTFE, PFA 1 to 20 l/min 5 to 45 l/min Discharge
Accessories Weight10 [kg] 45 1 It should have no condensation. 2 If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL-02-1994 cooling water system circulating type make-up water). 3 q Ambient temperature: 25C, w Circulating uid temperature: 20C, e Circulating uid rated ow, r Circulating uid: Tap
Built-in dust-protection mechanism A high degree of freedom for mounting Auto switch mountable 10 16 20 25 32 40 Bore size (mm) Fluid Air Double acting Action 0.1 to 0.6 0.15 to 0.6 Operating pressure (MPa) 10 to 60 C Ambient and fluid temperature 0.1 Repeatability Lubrication Not required Note) Effective gripping force (N) at 0.5 MPa 14 45 74 131 228 396 Note) Gripping point = Bore size
H unit Short spacer H unit Long spacer L:With low load shock absorber + Adjustment bolt With short spacer With long spacer H:With high load shock absorber + Adjustment bolt With short spacer With long spacer Port Port Spacers are used to fix the stroke adjustment unit an intermediate stroke position Shock Absorber Specifications Shock Absorber Model for L and H Units RB1412 19.6 12 1500 45
on upper and lower faces, Tapped on all faces (5 surfaces including end surface) RSQ Stroke adjuster (Rear end stroke only) RSG RS Scraper Can be mounted on standard products MI Theoretical Output Unit: N Operating pressure MPa Operating direction Piston area (mm2) Rod size (mm) Bore size (mm) 0.3 0.2 0.4 0.5 0.6 0.7 15 10 OUT 36 31 26 20 50 8 4 11 7 IN 26 23 19 15 38 34 23 OUT 79 68 57 45
Stroke Adjustment Unit Shock Absorber Model 25 32 40 RB1412 RB2015 RB2015 Port Port Shock Absorber Specifications 25 32 40 Applicable cylinder size (mm) RB1412 RB2015 RB2015 Shock absorber model Max. energy absorption (J) 19.6 58.8 58.8 Stroke absorption (mm) 12 15 15 Max. collision speed (mm/s) 1000 1000 1000 Max. operating frequency (cycle/min) 45 25 25 Extended 6.85 8.34 8.34 Spring force
type RJ0806U RJ1007U RJ1412U RJ2015U RJ2725U Model With cap L H L H H L L H L H Collision speed range Max. absorbed energy (J) Note) 0.5 1 3 10 30 70 6 x 0.75 O.D. thread size (mm) 8 x 1 10 x 1 14 x 1.5 20 x 1.5 27 x 1.5 4 Stroke (mm) 6 7 12 15 25 0.05 to 1 0.05 to 2 0.05 to 1 0.05 to 2 0.05 to 1 0.05 to 1.5 0.05 to 1 0.05 to 2 0.05 to 1 0.05 to 2 0.05 to 1 Collision speed (m/s) 80 80 70 45
Operating pressure [MPa] 0.15 to 0.6 0.1 to 0.6 Ambient and fluid temperature 10 to 60C (No freezing) Repeatability 0.1 Lubricant Non-lube Effective gripping force [N]1 at 0.5 MPa 14 45 74 131 Double-end type oil-impregnated resin bearings are used for all shafts. 1 Gripping point distance: 40 mm Model/Stroke Closing width [mm] (L1) Opening width [mm] (L2) Opening/Closing stroke [mm] (L2-
5.0 MPa Silencer Series VCHN 35 dB(A) noise reduction (At supply pressure of 4.0 MPa, back pressure 2.0 MPa) 45 dB(A) noise reduction model can be Made to Order. 1/10 Clogging reduction (SMC comparison) Double-layer sound absorbing material with different filtration reduces clogging. PAT.
Symbol Body size Symbol Standard characteristics Max. effective area (mm2) Port size Symbol Port size Symbol Symbol Standard characteristics Set pressure range (MPa) Without sub-plate Without sub-plate 1 2 3 Nil 02 03 13 9 5 Symbol 2 1/4 Nil 02 03 0.05 to 0.65MPa 1 3/8 2 1/4 0.1 to 0.9MPa 2 2 02 03 04 03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45
(Value in the initial stage) Vibration resistance: No malfunction from test with 45 to 1000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF. (Value in the initial stage) Symbol
(Valve in the inltial stage) Vibration resistance: No malfunction from test with 45 to 1000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF. (Value in the initial stage) Precautions Pilot Pressure Range Be sure to read this before handling.
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?