PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). 4 Snap shot function The current flow rate value can be stored to the switch output ON/OFF set point.
PF3A802H AC40#-D Y400-D Y400T-D E400-#04-D 4 : For more information about the options, refer to our website (URL https://www.smcworld.com).
They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. 04 Equivalent to M3 (L=6) 20 0.04 to 0.05 Nm 40 Equivalent to M4 (L=10) 0.09 to 0.10 Nm Element Description This unit supplies the fluid from the supply side main piping to the application.
, , M3 0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04
Selecting 04 in Setting mode activates the control setting mode. Small LED Product Status Reset whether or not an alarm has occurred. Each presses of the [MODE] key changes the operating mode as follows. Each presses of the [MODE] key changes the operating mode as follows.
ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External
L E Nil Standard Option/function Remote function 1 : +24V 2 : 24V COM (See section 3 remote ON/OFF function) 7 Output Cut off Alarm Common 6 Output Cut off Alarm a contact (OPEN During Alarm) 8 Output Cut off Alarm b contact (CLOSE During Alarm) 9 Temperature Alarm a contact (OPEN During Alarm) 11 Temperature Alarm b contact (CLOSE During Alarm) 10 Temperature Alarm Common 10 10m 02 2m 04
Applicable Applicable Symbol accuracy Element model Element length 002 2m Filtration Element Applicable 004 4m HEPO FGH100 Symbol efficiency length Element 300 006 6m 99% 100 L117 EJ701S 013 13m 200 L246 EJ801S,ED801S X20 0.2m Filtration FGH200 300 L496 EJ901S,ED901S efficiency Membrane 300 X40 0.4m 99.9% Element category Symbol Element J HEPO D Membrane Port size Port size Symbol (Rc) 03 3/8 04
(full span) Accuracy guarantee temperature range : 235 Suffix R: Bracket, Name plate, Mounting on the opposite side Note1) Accessories Port size 02 : 1/4 03 : 3/8 04 : 1/2 NIL: None B: Bracket (P36203018) G: Pressure gauge Note2) Note3) Thread type when Rc and G. Thread type when NPT.
Especially when using a 3-position exhaust center valve or a single acting cylinder take appropriate measures to prevent malfunction by using it with an individual EXH spacer assembly(VVFS4000-R-04-1,2). 1. Precautions for 2-position double solenoid valves 5.
Option Rated voltage Voltage symbol Part no. 100 VAC 100V VK300-82-2-01 110 VAC 110V VK300-82-2-03 200 VAC 200V VK300-82-2-02 Note) When requiring a gauge different than that mentioned above, specify the model number. 220 VAC 220V VK300-82-2-04 Option is packed with it.
How To Order Piston Rod Assembly Double Acting Single Rod NCA1 150 26A 0400 How To Order Cylinder Tube Double Acting Single Rod NC1A 150 04 0400 Bore 150 200 250 325 400 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Stroke (In Inches and Hundredths of Inches) *BLUE links will lead to purchase pages.
Maximum Flow Rate 1000 SFD200-C12, -02 SFD200-C08 SFD200-C10 Flow rate (L/min(ANR)) SFD100-C08, -02 A 100 SFD100-04 SFD100-06 10 0 0.5 1 Pressure (MPa) 320 Clean Air Filter SFD Series RoHS HAA HAW How to Order AT IDF IDU 1 0 SFD 0 C08 IDF FS Clean air filter IDFA Size Max. flow rate 100 L/min (ANR) 500 L/min (ANR) Option Option None Bracket (SFD100 only) IDFB Symbol 1 2 Symbol Nil B IDH
80.0 3/4, 1 90.0 950 ASS110 2.4 1/8 5.4 97 Meter-in control ASS310 16.5 1/4, 3/8 23.0 220 Specifications Air Fluid 0.7 MPa Max. operating pressure AS 5 to 60C (No freezing) Ambient and fluid temperature 0.1 to 0.5 MPa Set pressure ASP How to Order ASN 02 B ASS 00 3 AQ ASV Body size Accessory 1 8 Nil None With bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04
Example for Installation How to Order ADM200 Port size OUT IN Symbol 04 03 3 8 3 8 1 2 3 8 Voltage Constructions/Dimensions 100VAC Hz 1 50 60 200VAC Hz 50 60 240VAC Hz 50 60 110VAC Hz 50 60 220VAC Hz 50 60 24VDC 12VDC 2 3 4 5 6 7 Operating time/Applicable compressor 2 sec./min. (1 cycle/min.) /3.7 to 37kW 4 sec./min. (2 cycle/min.) /37 to 75kW 6 sec.
Note 2) On the AMC220,an R(PT)1/4 fitting can be attached by Note 1) Female thread: Available only AMC220, 320, 520 N NPT 04 1 2 F G(PF) 06 3 4 removing the drain cock. (It becomes the drain piping style) How to Order Oil Case Assembly If the oil case becomes damaged, it can be replaced easily.
HAl Accessories (Options) HAA7 AT Auto drain Applicable Model HAA7 HAA15 HAA22 HAA37 HAA7-F AD402-03 HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F AD402-03 HAA22-S HAA37-F AD402-04 IDl Dust protecting filter Mounting bench HAA37-S AMG How to Select (Flow Capacity l/min (ANR)) Operation Principle AFF Model HAA7 HAA15 HAA22 HAA37 AMl 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000
possible Blank: Combination not possible Applicable model Symbol SMC REGULATOR Specifications tSpacer ITV20mm ITV30mm ITV2000 Approx. 189 Set pressure max. 0.1MPa 1 P P Standard specifications Optional specifications Set pressure max. 0.5MPa 3 P P Approx. 133 Set pressure max. 0.9MPa 5 P P Connection Rc(PT) 1/4 02 P P eL-bracket rT-bracket Connection Rc(PT) 3/8 03 P P Connection Rc(PT) 1/2 04
DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4
Port size Body size Thread size Thread type Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.