Calculation of allowable external force (when moment load is applied) Calculation example When a load of f = 10N is operating, which applies pitch moment to point L = 30mm from the MHZ2-16D guide. 0.68 Allowable load F = 30 x 10-3 = 22.7 (N) M (maximum allowable moment) (Nm) Allowable load F (N) = L x 10-3 ( Unit conversion constant) Load f = 10 (N) < 22.7 (N) Therefore, it can be used.
Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit
With rubber cushion Foot type (includes mounting bolt) Front flange type (includes mounting bolt) Rear flange type (includes mounting bolt) Double clevis type (includes pin, snap ring, bolt, and flat washer) 76 111 145 190 373 518 1064 1839 Calculation (example) CDLQD32-20DCM-B Basic weight: CLQA32-20D-. 453g Additional weight: Magnet. 64g Rod end male threads . 43g With rubber cushion .3g
For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types. 516 10-SYJ5000 5 port solenoid valve Series How to Order Light/Surge voltage suppressor Electrical entry for G, H, L, M, W Electrical entry for D Type of actuation Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch
For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types. 495 4/5 port solenoid valve Series SYJ3000 How to Order Light/surge voltage suppressor Bracket Type of actuation Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar
x 14 7 Manual override VZ 7 14 P E P E 37.4 16 VS 29 32 43.8 VFN 4-PT 1/8 P , E port 2-3.5 Mounting hole 300 300 15.5 P = 10 1 2 3 4 5 n U side D side 40.2 15.5 46.2 19.4 A A 9.5 16.7 P = 10 n-M5 x 0.8 A port Dimensions Formula: L1 = 10n + 21, L2 = 10n + 7, n: Station (Max. 20 stations) n L L1 L2 2 41 27 3 51 37 4 61 47 5 71 57 6 81 67 7 91 77 8 9 10 121 107 11 131 117 12 141 127 13 151
Page 603-10 JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT Provided by customer (3 m) Communication cable To PWR Page 603-10 Power supply for controller 24 VDC Power supply plug (Accessory) Page 603-10 Options Teaching box Controller setting kit Conversion cable Note) Page 603-10 P5062-5 (0.3 m) Page 603-10 (With 3 m cable) LEC-T1-3G
Plug Barb elbow (H) 3.18/2.18 X M5 soft nylon Body rotates at 360 around the stud axis M-5E M-5ALHU-3 To plug unused M3 port polyurethane 3.18/2 X M5 P.2.1-51 M-3P Bulkhead reducer Reduction from Rc(PT)1/8 to M5 and includes panel mounting 4/2.5 X M5 6/4 X M5 soft nylon and polyurethane P.2.1-49 M-5ALHU-4 Rc(PT)1/8 X M5 female M-5ER Gasket M-5ALHU-6 P.2.1-50 To seal M3 thread P.2.1-52 M-3G
With bracket With light Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC Without DIN connector DIN terminal (With surge voltage suppressor) Enter symbols in the order below when ordering a combination of electrical option, other option, etc.
Avoid applications in which two or more end lock cylinders are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required. 4.9N 2 20, 25, 32 M2.5 x 0.45 x 25L or more M3 x 0.5 x 30L or more 40 10N 3 6. Use a speed controller with meter-out control. Lock cannot be released occasionally by meter-in control.
Finger Position/Narrow Type MHZ2-10N 5.4 Note) When using D-Y59, D-Y69 and D-Y7 type auto switches, through-hole mounting is not possible. 0 0.4 +2.2 0 When closed 5.7 When open 9.7 12-2-33 33 Series MHZ2 Dimensions MHZ2-16 Double acting/Single acting Basic type 30 16 2-M4 x 0.7 thread depth 4.5 (Mounting thread) +0.025 0 depth 3 3H9 4-M4 x 0.7 thread depth 8 (Mounting thread) Prepared hole
Option Teaching box Controller setting kit Teaching box (part number: LEC-T1-3G) Controller setting kit (part number: LEC-W2) [Controller setting software, communication cable, USB cable and conversion unit are included.] * In case of any shortages or damaged parts, please contact the selling office. (2) Installation Please refer to the 3.4 How to install (page 14) (3) Wiring and connection
DIN terminal (With surge voltage suppressor) VXD XL Lead wire length XL1 XL2 XL3 XL4 600 mm 1000 mm 1500 mm 3000 mm Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC DIN terminal (With surge voltage suppressor) Enter symbols in the order below when ordering a combination of electrical
Finger Position/Narrow Type MHZ2-10N 5.4 Note) When using D-Y59, D-Y69 and D-Y7 type auto switches, through-hole mounting is not possible. 0 0.4 +2.2 0 When closed 5.7 When open 9.7 12-2-33 33 Series MHZ2 Dimensions MHZ2-16 Double acting/Single acting Basic type 30 16 2-M4 x 0.7 thread depth 4.5 (Mounting thread) +0.025 0 depth 3 3H9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
Example Manifold Assembly Orders: Standard Configuration Manifold: Mixed Configuration Manifold: LINE ITEM DESCRIPTION LINE ITEM DESCRIPTION Four Station Manifold Ass'y as follOWS: Six Station Manifold Ass'y as follows: Sta. 1) NVFR31 OO-SFZ Sta. 2) NVFR3200-SFZ Sta. 1) NVFR2110-3G Sta. 2-6) NVFR2210-3G NWSFR2-10-06M-02T NARBF3000-00-P-1 WFS3000-20A-1 AXT636-1 A (P gallery) ) Mix: sta. 1)
Electric actuator *1) Prepared by user *6) I/O cable Part No: LEC-CN5PLC *3) *4) Power supply 24 VDC Controller to CN5 *1) *6) *6) Controller setting kit *2) *5) Actuator cable Part No: LE-CP--S Part No: LEC-W2 LE-CP--B-S to CN3 to CN4 (Standard cable) LE-CPLE-CP--B to CN2 (Robotic type cable) Teaching box to CN1 (with 3m cable) Part No: LEC-T1-3G *3) Power supply plug (accessory) Controller
DIN terminal (With surge voltage suppressor) Example) VX2 Z Z 1A 1 2 A Electrical option With light Other option Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC Without DIN connector DIN terminal (With surge voltage suppressor) Options marked with are available for Class H coil.
KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
LQ LVN Table(1) Connection Size and Applicable Model Table(2) Rated Voltage-Electrical Entry-Electrical Option Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) TI/ TIL Applicable model VXR2150-04 VXR2150-06 VXR2260-10 1 VXR2270-12 1 VXR2380-14 2 VXR2390-20 Size Class B Class H G PA 1 2 3 4 C D, T G, C T S L,
For the lever type with a built-in shock absorber (without a lock mechanism), the lever may be pushed back in the opposite direction to the transfer direction due to the return force of the shock absorber, if 10N of thrust or more in the transfer direction is not applied to the lever after the pallet collides with the lever.