Panel mount Apply atmospheric pressure then do 0 clear. ZSP ISl ZSM 1 Turn screw 1/4 to 1/2 turn after panel makes contact with the sealing surface of the PSE. PFl IFl Removal from DIN rail Mounting on DIN rail 2a 2b Others Caution 1. Time delay for power on reset of controller is 0.5 seconds.
Do not pull on the cord.Have the case when remove the ECC-PNAL-232CAB cable. This cable might break when the code part of this cable is pulled when this cable is removed. Install the cover or the memory cassette after removing the ECC-PNAL-232CAB cable. Turn off the power supply when you install or detach the ECC-PNAL-232CAB cable.
Do not use in locations where there is splashing or spraying of oils and solvents. OUT2 OUT1 3. When using a commercially available switching regulator, be sure to ground the FG terminal. SET 4. In locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port.
Do not set the mist generating pressure differential to exceed 0.2 MPa. Warning PPA 1. Before removing the oil filler plug, loosen it two and half turns to completely release the pressure in the bowl. This will prevent the oil filler plug from flying out.
When the line is stopped,do not adjust or set the differenital pressure, as it could cause the differential adjustment valve to break. 3. When setting the pressure differential, if there is a fluctuation in the operating flow rate, set the pressure differential at the lower flow rate range. ITV IC Inlet Outlet VBA VE VY1 G Piping PPA Warning Mist generation part AL 1.
Do not use the regulator with flow exceeding the Max. flow indicated in Flow Characteristics as this can cause failure in pressure adjustment. Bleed port AU AF Handle locking screw AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Caution No.
Do not use a lubricator on the inlet side because it could clog the bleed holes and lead to a malfunction. 14-4-60 1 Regulator for 2 MPa Series ARX20 F.R.L.
Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
To install a directional switching valve, do so on the output side of the pressure-reducing valve. 1. If drainage or debris is present in the supply pressure line, the fixed throttle becomes clogged, resulting in a malfunction. Therefore, in addition to the air filter (SMCs AF series), make sure to use a mist separator (SMCs AM, AFM series).
Do not use in an environment, where water or oil is splashed. Because it is the open type construction. If water or oil were to make an ingress, the electrical circuit would be corroded and result in a malfunction or damage. 2. Operating fluids are either air or inert gas exclusively. Never use liquids. 3. Never use in an environment where flammable fluid or gas is used.
Therefore, do not operate it in an environment that is exposed to chemicals such as thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting oil (alkalinic). 2.
Do not use in locations where there is splashing or spraying of oils and solvents. 3. When using a commercially available switching regulator, be sure to ground the FG terminal. OUT2 OUT1 SET 4. In locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port.
When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. (Crimping tool: model no. DXT170-75-1) Set point ON When assembling the connector to the switch housing, push the connector straight onto the pins until the lever locks into the housing slot.
When piping and fittings, etc. are being screwed together, be certain that cutting chips from the pipe threads, sealing material, and other debris do not get inside the piping. Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the pipe. 3. The unit should be mounted vertically. 4.
If even one of the cups do not seal, there can be a loss of pressure to all cups. SMC addresses this problem with series INO Self Sealing Vacuum Cups. By utilizing a small mechanical check valve, it only opens when the cup comes in contact with a part. This will maintain system vacuum pressure if one part is absent.
BRAZIL SMC Pneumaticos Do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. VENEZUELA SMC Neumatica Venezuela S.A. ASIA CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong Kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. MALAYSIA SMC Malaysia (S.E.A.) Sdn. Bhd. PHILIPPINES SMC Pneumatics (Philippines), Inc. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd.
SlA w Note that in case of the option of different "1(P)" porting position, porting indication on the body and flow direction by handle operation are reversed. e Do not supply air pressure from other ports than 1(P) port. The valve may have air leakage when air pressure is supplied from other ports.
Note) Do not use excessive force to remove the connector as this might loosen the wire connections inside the connector. Open the cover by inserting a small flat head screw driver into the slot on the side of the pilot assembly(see drawing below), lift the cover out about 1 mm and then pull off.
SYJ W Non-locking push style (Flush) SX VK Note: To avoid contact failure and broken wires, do not pull out the lead wire with excessive force.