SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20AF-V-P-M5-J"

Allowable Kinetic Energy 12 16 20 25 Bore size (mm) lbf-ft J J J lbf-ft J lbf-ft lbf-ft 0.066 0.090 0.055 0.022 0.028 0.038 0.016 Standard 0.041 0.133 0.180 0.110 0.043 0.055 0.075 0.032 With rubber bumper 0.081 Minimum Operating Pressure 20/25 12/16 Bore size (mm) MPa psi MPa psi Min. operating pressure 0.05 7.3 0.07 10.2 2 Compact Cylinder Series CQS OUT IN Double Acting Single or Double

Please refer P 8-4 for how to mount. 9. Refer to Fig. 8-6 to mount the plug to the piping of the product.

S WH ZZ MM K JD JC Bore size (mm) 252 1/4 192 15.0 13 M22 x 1.5 30 26 M8 x 1.25 33.5 22 5 30.5 43 20 5.8 to 8.8 257 1/4 193 19.6 17 M24 x 1.5 36.9 32 M10 x 1.25 37 27 5.5 25.5 39 25 265 3/8 195 19.6 17 M30 x 1.5 43.9 38 M10 x 1.25 43.5 27 5.5 28.5 36 32 6.8 to 11.3 277 3/8 201.5 25.4 22 M33 x 2.0 47.3 41 M14 x 1.5 52.5 30 7.5 23 32 40 50 to 100 Rc P EA Rc P EA GA NE 8-J GA WH ND H1 MM I D

Request message (Master to Slave) STX Slave Address Request Command ETX BCC [STX] XX XX [R] [P] [V] [1] [ETX] XX Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC [STX] XX XX [ACK] [P] [V] [1] XX XX XX XX XX [ETX] XX Communication example Slave AddressNo 1 BCC selection Your system This product (Request) [STX] 01RPV1 [ETX] [65h] Data

NPN) Reed switch Solid state switch Z76 5 V IC Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Relay, PLC 100 V, 200 V 2-wire 24 V Diagnostic indication (2-color) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC Grommet 100 V, 200 V 12 V 2-wire 3-wire (NPN) 3-wire (PNP) IC Relay, PLC 5 V, 12 V Diagnostic indication (2-color) 12 V 2-wire 24 V Water

0 V 0 V 24 V G D G D SI unit SI unit Master unit D 0 V24 V G D 0 V24 V G D 0V 24V G D 0V 24V L2 L1 G LINE1 LINE2 SHIELD L1 L2 Power supply 24 V 0 V 0 V 24 V SHIELD SHIELD Transmission line L1 L2 FG 24 V 0 V L1 L2 FG 24 V 0 V Black White Brown Blue Terminal resistor Main transmission line Transmission line Crimped connector SL-J1A Power supply 24 V 0 V 0 V 24 V Type 3 ground Type 3 ground

Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes 24 V 100 V Relay, PLC M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes 24 V Relay, PLC M9B 2-wire 12 V Lead wire length symbols 0.5 mNil

How to see the manufacturing code P O 001 January 2011 O O 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2011 P Repeated from A to Z in alphabetical order 1 O Repeated from O to Z in alphabetical order, with O for January and Z for December 2012 Q 2 P 2013 R 3 Q Fig. 1-3 Position of product label 1.4.2 Earth Label Fig. 1-4 Earth label HRS Series 1.4 Other Labels 1-5 HRX-OM-O021

SVRE OFF [BK RLS]DC24V [BK RLS] [BK RLS]DC24V [BK RLS] EMG /LEC 58 - 15. 15.1. / 15.2 ON 59 - 5 () 60 - 15.3 50mm 15.4 ( ) 61 - 15.5 15.6 D 100 15.7 62 - 16. , , (), 16.1 /P.16 4. LED() /P.18 5.CN1: PLC /P.24 6.3 CN1 CN5 DC24V /P.16 4. /P.27 6.4 I/O /P.48 12. ONOFF /P.11 3. /P.48 12. CN1 CN5 DC24V /P.16 4. /P.27 6.4 I/O /P.14 3.4 63 - /P.28 7. (CN1:EMG ) /P.11 3.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Evaporation thermometer V Dustproof filter provided as a standard accessory V All electrical components are located in the front of the product.

For example, when analogue output is 1 to 5 V, F.S.=5[V] 1[V]=4[V]. (Reference: 1%F.S. = 4[V] 1% = 0.04[V]) F F.S. (full span / full scale) Fluid contact part A part that comes into physical contact with the fluid. I Instantaneous flow The flow passing per unit of time. If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute.

Pulse train signal specifications (Open collector input and differential input are common) 5 s or more 24 V 21.6 V to 26.4 V 5 V 4.75 V to 5.25 V PP3s or less 5 s or more 3s or less 16 s or more 28 - 7.4 Parallel I/O signals (Pulse Input Type) (1) Input side (Pulse input type) Function Description Common terminal for the input signal power supply.

Make sure to ground. +24 V +24 V Brown + 24 VDC Brown + 24 VDC +24 V Power supply 24 VDC +24 V Power supply 24 VDC Blue 0 V Blue 0 V 0 V 0 V F.G. F.G. Make sure to ground. Make sure to ground.

cock with barb fitting: 6 x 4 nylon tube Body size 30 40 Thread type Metric thread (M5) Rc NPT G Nil Display units for product name plate, caution plate for bowl, and pressure gauge: PSI, F Accessory AW40 Direct operated type, Relieving type Port size 02 03 04 06 Option specifications Applicable filter regulator AW30/40 Accessory Symbol B C D E G P 1 2 6 8 C J N R W Z With bracket (with

H7 depth D 2 x V H7 depth I 4 x NN depth S N 2 x NPT 1/4 G 2 x 2 x MM depth J Hexagon socket head plug 2 x NPT 1/4 G E B RB (mm) Bore size (mm) 50 63 80 C D E GA GB GC I J K L LA LB MM N NA NB NC NN P B 95 48 12 13.7 134.3 138.5 93 10 12 55 376.4 149.5 78.4 M10 x 1.5 19 13 36.5 10.3 M8 x 1.25 10 112 54 12 16.6 141.2 147.5 90.5 10 12 55 395.6 158.5 78 M10 x 1.5 22 13 36.5 15.8 M8 x 1.25 10