SMC Corporation of America
Elite Part Number Search
Search Results "XLD-40L-M9PA"

(P.29~32) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.

DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516

(P.20) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Note 1) For the tightening of the mounting screws (M2.5), use a precision screwdriver with a handle diameter of approximately 5 to 6 mm.

(P.27 to 29) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.

(NPN) D-M9NV D-M9N DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA

(NPN) D-M9NV D-M9N DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA

entry (Output) (Nil) (M) (L) (Z) M9NV M9N 3-wire(NPN) F8N IC 5V, 12V circuit M9PV M9P 3-wire(PNP) Solid state auto switch F8P M9BV M9B 2-wire 12V F8B Relay, Grommet Yes 24V PLC 3-wire(NPN) M9NWV M9NW IC 5V, 12V Diagnostic indication circuit 3-wire(PNP) M9PWV M9PW (2-color indicator) 2-wire 12V M9BWV M9BW 3-wire(NPN) M9NAV*1 M9NA*1 5V, 12V IC Water reisstant circuit 3-wire(PNP) M9PAV*1 M9PA

In-line 0.5 1 3 5 entry (Output) (Nil) (M) (L) (Z) 3-wire(NPN) M9NV M9N IC 5V, 12V circuit 3-wire(PNP) M9PV M9P Solid state auto switch 2-wire 12V M9BV M9B 3-wire(NPN) 5V, 12V IC M9NWV M9NW 24V Diagnostic indication Relay, circuit 3-wire(PNP) Grommet Yes M9PWV M9PW (2-color indicator) PLC 2-wire 12V M9BWV M9BW M9NAV*1 M9NA*1 3-wire(NPN) 5V, 12V IC Water reisstant circuit 3-wire(PNP) M9PAV*1 M9PA

.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) D-P3DW Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.How to Mount and Move the Auto Switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting

.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.

entry connector load DC AC Perpendicular In-line (Nil) (M) (L) (Z) 3-wire (NPN) M9NV M9N IC 3-wire (PNP) 5V,12V circuit M9PV M9P 2-wire 12V M9BV M9B Solid state auto switch 3-wire (NPN) M9NWV M9NW IC Diagnostic indication 3-wire (PNP) 5V,12V circuit M9PWV M9PW (2-color indication) Relay, 2-wire 12V M9BWV M9BW 24V Grommet Yes 3-wire (NPN) *1 M9NAV *1 M9NA PLC IC Water resistant *1 M9PAV *1 M9PA

.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.How to Mount and Move the Auto Switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting bracket

(Z) 0.5 (Nil) 1 (M) 3 (L) In-line Perpendicular 3-wire (NPN) M9N M9P M9B M9NW M9PW M9BW M9NA M9NV M9PV M9BV M9NWV M9PWV M9BWV IC circuit 5V, 12V 3-wire (PNP) Solid state auto switch 2-wire 12V 3-wire (NPN) IC circuit Diagnosis (2-color indication) 5V, 12V Relay, PLC Grommet Yes 24V 3-wire (PNP) 2-wire 12V M9NAV 3-wire (NPN) IC circuit Water resistant (2-color indicator) 5V, 12V M9PAV M9PA

AC Perpendicular In-line MHT M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V 12 V 3-wire(PNP) Solid state auto switch MHY 2-wire 3-wire(NPN) IC circuit Diagnosis (2-color indicator) MHW MHW 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire -X M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA

Nil) 1 (M) 3 (L) DC AC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V Solid state auto switch 12 V 3-wire(PNP) 2-wire 3-wire(NPN) IC circuit Diagnosis (2-color indicator) 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA

Magnet: D (Built-in), Rod Type: Standard, Mounting: D (Double Clevis), Bore Size: 100mm, Stroke: 100mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bearing Type: M (Slide Bearing), Bore Size: 63mm, Port Type: TN (NPT), Water Resistant: R (NBR Seals, Nitrile Rubber), Stroke: 75mm, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Bearing Type: M (Slide bearing), Bore Size: 40mm, Port Type: TN (NPT), Stroke: 25mm, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal

Bearing Type: L (Ball Bushing), Bore Size: 40mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 30mm, Stroke Adjustment: A (0 to 10), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Bore Size: 40mm, Port Type: N (NPT), Stroke: 75mm, Lock Position: H (Rear Locking), Manual Override: N (Non-locking Type), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)