9.3 19.2 36 (37) AS32l1FSl-U03-08 8 13.2 22.7 33 28 14.2 AS32l1FSl-U03-10 10 15.9 26.7 37 15.6 39 (40) AS32l1FSl-U03-12 12 18.5 29.7 40 26.8 17 41 (42) AS42l1FSl-U04-10 10 1/2 24 (23.8) VCHC 3/8 19 16.6 55.4 54 50.2 48.8 ASR ASQ 15.9 18.8 27.4 40.3 (40.2) 36.2 64.1 62.5 57 55.4 15.6 26 29 10 19 60 (59) AS42l1FSl-U04-12 12 18.5 30.8 43.7 (43.6) 35.1 17 62 (61) AS42l1FSl-U04-16 16 23.8 34.8
37.5 43 50 Hs 27.5 30 33.5 38 43.5 50.5 59 69.5 Bore size Bore size 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 8.5 11 11.5 21.5 21.5 30.5 31.5 12 14.5 15 14.5 25 25 20.5 21 22.5 34.5 34.5 45.5 45.5 24 24.5 26 26.5 38 38 10 12.5 13 23 23 31.5 32.5 22 22.5 24 36 36 47 47 8 9.5 10 20 20 29 30 19 19.5 21 33 33 44 44 13 15.5 16 15.5 26 26 25 25.5 27 27.5 39 39 12.5 15 15.5
or less Rubber seal 77 VQ1400 20 or less 0.72 0.68 0.25 0.15 0.18 40 or less 0.16 26 or less Metal seal Exhaust center VQ1401 25 or less 1.0 0.70 0.30 0.20 0.25 47 or less 0.16 33 or less Rubber seal VQ1500 0.72 0.70 0.25 0.15 0.18 40 or less 0.16 26 or less Metal seal 20 or less Pressure center VQ1501 0.65 0.85 0.42 0.20 0.18 47 or less 0.21 33 or less Rubber seal 25 or less VQ2100 2.0
C Q + Stroke Shock absorber Shock absorber RB0805 Side plate Section IF (CY1L6) (mm) A B D d C EA FA EB Model G HP J JK FB GP H HB HG HI HO HS HT HA CY1L6 CY1L10 7.6 8 3 6.5 7 M4 x 0.7 6 26 6.5 36 27 10 11 9 25 14 16 5 12 10 4 8 8.5 M5 x 0.8 6 3 12 7.5 33 9.5 5 50 34 17.5 14.5 13.5 33 21.5 18 6 PA (N) (NA) (NB) RW Q Z W tb ta T PB MM NN M L QW LD Model CY1L6 CY1L10 TT PW 12 54 68 56 10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 33 20 13 MIW12 MIS12 MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 M5 x 0.8 Plug part no: M-5P Turn another 1/6 turn with a tool after manual tightening.
Local Area: (800) 258-9200-www.stevenengineering.com CX General Purpose Type P. 8-30-10 Band, Rail, Tie-rod, Direct Mounting 2-color Indication Type P. 8-30-18 Band, Rail, Tie-rod Mounting D-X 20Data P. 8-30-20 Solid State Switches General Purpose Type P. 8-30-21 Band, Rail, Tie-rod, Direct Mounting Normally Closed Type P. 8-30-31 Direct Mounting 2-color Indication Type P. 8-30-33
Bore size Standard stroke (mm) MM YY L X K W J V H GA GB TA TB U G T F S DA R C Z NN Q B ML P PW YL (mm) 12 16 20 25 18 50 13 5 16 40 58 5 7.5 5 36 29 56 8 22 6 48 29 12 14 39 7 10, 20, 30, 40, 50, 75, 100 M4 x 0.7 10 M4 x 0.7 M5 x 0.8 7 M4 x 0.7 11 22 54 15 7 18 42 64 2.5 8 5.5 38 33 62 8 25 8 52 33 13 16 43 8 10, 20, 30, 40, 50, 75, 100 M5 x 0.8 13 M5 x 0.8 M5 x 0.8 5 M5 x 0.8 11 20, 30
Local Area: (800) 258-9200-www.stevenengineering.com CX General Purpose Type P. 8-30-10 Band, Rail, Tie-rod, Direct Mounting 2-color Indication Type P. 8-30-18 Band, Rail, Tie-rod Mounting D-X 20Data P. 8-30-20 Solid State Switches General Purpose Type P. 8-30-21 Band, Rail, Tie-rod, Direct Mounting Normally Closed Type P. 8-30-31 Direct Mounting 2-color Indication Type P. 8-30-33
Local Area: (800) 258-9200-www.stevenengineering.com CX General Purpose Type P. 8-30-10 Band, Rail, Tie-rod, Direct Mounting 2-color Indication Type P. 8-30-18 Band, Rail, Tie-rod Mounting D-X 20Data P. 8-30-20 Solid State Switches General Purpose Type P. 8-30-21 Band, Rail, Tie-rod, Direct Mounting Normally Closed Type P. 8-30-31 Direct Mounting 2-color Indication Type P. 8-30-33
) 0 (15) 12 D-M9, D-M9V 10 (17) 0 0 28 33 (45) 18 28 (35) 5 (17) D-F9W, D-F9WV 10 (17) 0 0 28 33 (45) 18 28 (35) 5 (17) D-A9, D-A9V 0 (15) 0 0 32 32 (47) 22 22 (37) 0 (15) 16 D-M9, D-M9V 10 (17) 0 0 32 37 (49) 22 32 (39) 5 (17) D-F9W, D-F9WV 10 (17) 0 0 32 37 (49) 22 32 (39) 5 (17) D-A9, D-A9V 0 (15) 0 0 38 38 (53) 26 26 (41) 0 (15) 20 D-M9, D-M9V 10 (17) 0 0 38 38 (55) 26 36 (43) 0 (17)
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.
Set value P_1 Hysteresis H_1 Troubleshooting Flow Without flow adjustment valve (using ZS-33-M) With flow adjustment valve (using ZS-33-MS) Do not operate in an atmosphere containing flammable, explosive or corrosive gas. Fire or an explosion can result. This product is not designed to be explosion proof.
SoG/SoR/REd/GRN(33 ) 5. [F 1] OUT1 -28No.PF-OMM0004-D 1. [F 1] [oUt1] 2. ON-OFF -29No.PF-OMM0004-D 3. a. ([n_1]) (33 ) b. ([n1L]) [P1H] or [n1H] ([n1H]) (33 ) -30No.PF-OMM0004-D c. / -31No.PF-OMM0004-D ( [n1AH]) ( [n1dH]) 3 1 3 6 6 1 6 3 1 1 -32No.PF-OMM0004-D 4. OUT1 5. [F 1] OUT1 -33No.PF-OMM0004-D -34No.PF-OMM0004-D -35No.PF-OMM0004-D [F 2] OUT2 OUT2 OUT1 1.
SoG/SoR/REd/GRN(33 ) 5. 5. 5. 5. [F 1] OUT1 28 No.LFE*-OMY0008 1. 1. 1. 1. [F 1] [oUt1] 30 () 2. 2. 2. 2. (ON-OFF ) 29 No.LFE*-OMY0008 3. 3. 3. 3. a. ([n_1]) (33 ) b. ([n1L]) [P1H] or [n1H] ([n1H]) (33 ) 30 No.LFE*-OMY0008 c. ()/() ( [n1AH]) ( [n1dH]) () 31 No.LFE*-OMY0008 ( ) 3 6 3 1 3 6 6 1 1 1 32 No.LFE*-OMY0008 4. 4. 4. 4.
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can cause malfunction or damage the product. Do not perform wiring while the power is on.
Refer to About offset function (P.5-33) for details. This function can be set on Offset setting screen. Refer to Table 5.4-6 Offset setting for details. (1) (2) Offset setting Table 5.4-6 Offset setting No. Indication Item Explanation Setting range (1) Offset Temp.
Refer to Communication Function of Operation Manual for details. (1) (2) (3) (4) Ethernet communication setting screen Table 5.4-33 Setting of ethernet communication No.
Description Material Note 31 Auto switch 32 Magnet 33 Switch spacer Resin 24 - Angle adjustable type Component parts No.
5 or less 30 190 39 68 43 10 or less 43 72 29 5 or less 50 190 49 83 33 10 or less 53 87 22 5 or less 70 190 54 95 30 10 or less 58 99 21 5 or less 100 190 61 108 27 10 or less 65 112 18 5 or less 200 190 81 139 21 10 or less 85 143 15 5 or less Operating range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.