L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Port size Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Plug Yes No No Yes Socket Yes Yes No No Availability Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.
2 1 B 1 2 20 2B 1 4 B IN-OUT reversal direction T Element service indicator Option AMD800 to AMD1000 Self-standing type AMD801/901 Piping support type 20 01 AMD 8 20 00 AMD 8 Port size Body size Port size Body size 8 8 20 2B flange 30 3B flange 20 2B flange 30 3B flange 9 9 10 40 4B flange 40 4B flange 60 6B flange Type Type 00 With manual drain cock 10 With auto-drain 01 With manual drain
F0 Selection of connected sensor Unit selection function 22 F1 Setting of OUT1 24 F2 Setting of OUT2 27 F3 Operating fluid 28 F4 Reference condition 29 F5 Response time 30 F6 Display mode 31 F7 External input 32 F8 Display resolution 35 F9 Auto-preset 36 F10 Accumulated value hold 38 F11 Analogue output filter 39 F12 Power saving mode 40 F13 Security code 41 F98 Setting of all functions 42
(Refer to page 42) Check that the brown, blue, black and white wires are connected correctly. Incorrect wiring Correct the wiring. External input does not operate No reaction to the external input For external inputs, the white wire should be connected to GND for 5 ms or more.
ID 0 OUT0 bit 0,1 1 OUT1 bit 0,1 2 OUT2 bit 0,1 3 OUT3 bit 0,1 00 4 OUT4 bit 0,1 5 OUT5 bit 0,1 6 bit 0 7 bit 0 ID1 0 BUSY bit 0,1 1 SVRE bit 0,1 2 SETON bit 0,1 3 INP bit 0,1 01 4 AREA bit 0,1 5 WAREA bit 0,1 6 ESTOP bit 0,1 7 ALARM bit 0,1 (LECP6) (LECA6) 32 - / Byte No.
H 28 30 36 44 54 G 33 42 44 50 61 F 45 55 58 65 76 E 22 21 26 D 34 46 63 67 78 C 40 53 70 75 90 B 20 29 39 42 53 A 59 78 107 110 134 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 5-8-22 5 Series VHS Specific Product Precautions Be sure to read before handling. Air Supply Precautions on Design Warning Warning 1.
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
Dimensions 46.5 Cover 26.5 12 14 Turn counterclockwise until the cover stops. 42 Pull R1/4 2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the limit indicator. Be careful not to bend other needle or damage the dial plate.
Actuator operation from host . 40 8.1 CiA 402 drive profile . 40 8.1.1 FSA state . 40 8.1.2 Controlword / Statusword . 41 8.1.3 Control mode . 42 8.2 Parameter setting . 43 8.3 Servo-on and Homing . 44 8.4 Positioning operation (Profile position mode) . 45 9.
Note) Return to origin of all axes should be completed before operating any teaching methoddJOG tab 42 - 1) JOG Teaching +/button Select the JOG tab. Set the movement speed of the axis for teaching in the Speed column.
(Nm) L(mm) MHM-16D M6x1 5.2 11.5 MHM-25D M8x1.25 12.5 12.4 MHM-32D M10x1.5 24.5 13.5 MHM-50D M12x1.75 42 16 3.
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 42 52 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 56 65 Two mounting screws (for mounting
H 28 30 36 44 54 G 33 42 44 50 61 F 45 55 58 65 76 E 22 21 26 D 34 46 63 67 78 C 40 53 70 75 90 B 20 29 39 42 53 A 59 78 107 110 134 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 3
Example) AL30-03B-2R Symbol Description Body size 20 30 40 50 60 10 Metric thread (M5) Rc NPT G Nil Thread type N F + M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 Port size + Nil B Note 1) Option (Mounting) Without mounting option With bracket + Polycarbonate bowl 1000 cm3 tank 1000 cm3 tank (with switch) Lowest limit ON 1000 cm3 tank (with switch) Lowest limit OFF Metal bowl Nylon bowl
38 35 42 40.5 A 33 32.5 34 31 38 36.5 49.5 48.5 A B A B A B A B 20 25 32 40 50 63 80 100 B 24 (32) 24.5 (32.5) 25 (33) 27 (36) 32 (44) 33.5 (45.5) B 14.5 (22.5) 15 (23) 15.5 (23.5) 17.5 (26.5) 22.5 (34.5) 24 (36) 29 (43) 30 (44) B 20 (28) 20.5 (28.5) 21 (29) 23 (32) 28 (40) 29.5 (41.5) B 16 (24) 16.5 (24.5) 17 (25) 19 (28) 24 (36) 25.5 (37.5) 30.5 (44.5) 31.5 (45.5) Hs 27.5 30 33.5
10.4 2 x 6.5 2 x 6.5 42 8 54 66 Back side mounting Bottom mounting 1684 VR51 Series Specific Product Precautions 1 Be sure to read this before handling the products.
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
(Band) Cylinder series Applicable bore size (mm) 200 40 180 160 32 140 50 20 25 63 80 100 125 CDV3, CDVS CE2, CNA CDL1 CDS1 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M BS1 -125 BS1 -140 BS1 -160 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1 -04M RHC BMB1 -050 BMB1 -063 BMB1 -080 BMB1 -100 BMB2 -032 BMB2 -040 MDB 7-9-41 42 Technical Data 2: How to Mount and Move the Auto Switch Mounting