Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: NPT, Port Size: 1/4, Pressure Rating(MPa): 1, Driving Type: Pilot Type Spool, Pilot

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-PositionExhaust Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: NPT, Port Size: 1/4, Pressure Rating(MPa): 1, Driving Type: Pilot Type Spool, Pilot

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): 200 or less, Pipe Port Type: NPT, Port Size: 1/4, Pressure Rating(MPa): 0.2~1, Driving Type

Actuation: 3 Position Closed Center, Mounting/Porting: Top Ported, Seal: Rubber Seal, Pilot Specification: Internal Pilot, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Light/Surge Suppressor/Common Specification: Without light/surge voltage suppressor, Non-polar, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread: NPT, Mounting Option: -, Pressure

Actuation: 2 Position Single, Mounting/Porting: Top Ported, Seal: Rubber Seal, Pilot Specification: Internal Pilot, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Light/Surge Suppressor/Common Specification: Without light/surge voltage suppressor, Non-polar, Manual Override: Non-locking Push Type, A,B Port Size: 1/4, Thread: NPT, Mounting Option: -, Pressure

No.EX-OMW0014CN-A PROFINET SI / / EX245-SPN1A/2A/3A(SI ) EX245-DX1() EX245-DY1() EX245-LA1/LB1(IO-Link ) EX245-EA2-() 1. 11 1.1. 11 1.2. 12 2. 13 3. 14 3.1. 14 3.2. 16 4. 22 4.1. 22 4.2. 26 5. 30 5.1. 30 5.2. 34 6.SI 35 6.1. 35 6.2. 37 6.3. 39 6.4.LED 40 6.5. 43 7.EX245-DX1 46 7.1. 46 7.2. 47 7.3. 48 7.4. 48 7.5 LED 49 7.6. 50 8.EX245-DY1 51 8.1. 51 8.2. 52 8.3. 53 8.4. 53 8.5.LED

EX245-DX1 . 51 7.1. . 51 7.2. . 52 7.3. . 53 7.4. . 53 7.5. LED . 54 7.6. . 55 8. EX245-DY1 . 56 8.1. . 56 2 No.EX-OMU0020CN 8.2. . 57 8.3. . 58 8.4. . 58 8.5. LED . 59 8.6. . 60 9. EX245-EA2-1/2 . 61 9.1. . 61 9.2. . 62 10. . 63 10.1. . 63 10.2. Y . 64 10.3. (M12 ) . 66 11. . 67 11.1. . 67 12. . 68 12.1. EX245-SPN1 . 68 12.2. EX245-DX1 . 70 12.3.

If no button operation is performed within 30 seconds, the display will turn off again. 51 No.PF-OMU0002-D [F81] Security code The security code can be turned on and off and the security code can be changed when unlocked. < Operation > Display [F81] by pressing or button in function selection mode. Press the S button.

For details, please refer to the "When the set value and hysteresis of the switch output (OUT1/OUT2) is set within the zero-cut range (page 51)". -49No.PF-OMY0005-A Set pressure range Zero cut-off set value Zero cut-off range Displayable pressure range 0.0 0%F.S. -0.050 to 1.050 MPa -0.050 to -0.010 MPa 1.0 0 to 1%F.S. 0.010 to 1.050 MPa (Displays 0 when the value is -0.009 to 0.009 MPa)

Setting Mode 26 Simple Setting Mode 28 Function Selection Mode 29 Function selection mode 29 Default setting 29 F0 Flow range, display units and switch output selection 31 F 1 Setting of OUT1 35 F 2 Setting of OUT2 40 F 3 Digital filter setting 43 F 5 FUNC terminal function setting 44 F10 Sub display setting 47 F14 Display with zero cut-off setting 49 F30 Accumulated value hold setting 51

[F10] [ SUb] Sub screen display setting Page 51 [ dEF] Standard (fluid temp. displayed) : When a temperature sensor is connected.

No.PF-OMN0011CN-C / / PF3W3## SMC 2 9 12 13 15 15 16 21 23 23 F0 25 F1 OUT1 26 F2 OUT2 34 F3 40 F10 41 F20 45 F22 46 F30 48 F80 49 F81 50 F82 51 F90 52 F96 53 F97 54 F98 57 F99 58 59 62 63 66 66 69 71 -1No.PF-OMN0011CN-C (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules

No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

PV SV 51. Set the monitoring time before the "Dust-proof filter maintenance" alarm is generated with [] key or [] key, and press [SEL] key to enter.

Set range is AL.01 to AL.51. to Communication mode Setting and checking 37. Press the [SEL] key once. The set screen of communication mode is displayed on the digital display. PV SV 38. Select communication modeDIOfrom the table below with [] key or [] key, and confirm by pressing SEL.

Figure 5-51 Setting screen 3. With the use of the arrow keys([], []),move the cursor to 3.INITIAL SET and press the [ENT] key. L The Initial setting screen 1is displayed. Figure 5-52 Initial Setting screen 1 4. With the use of the arrow keys([],[]), Move the cursor to Initial Setting screen 3.

I J K L M N O P Q 76.5 40 46 28 11 14.5 28 15 16 91 46.5 58 32 15 16 30.5 16 21.5 110 55 68 36 16.5 22 37.5 17.5 24.5 A B C D E F G H ML2B25 110 220 206 42 138 93.5 16 73 ML2B32 140 280 264 51 168 107.5 19 88 ML2B40 170 340 322 59 204 130.5 23 106 LD LL MM NN PP SS YY ZZ 5.6 9.5 M5x0.8 9 Rc1/8 30 37.5 Rc1/16 6.8 16 M6x1 12 Rc1/8 35 45 Rc1/16 8.6 15 M8x1.25 14 Rc1/4 40 54 Rc1/8 V 26 7-2

LEF-OM00601 / / / LEF Series LECSeries /LEC6 . 2 1/. 4 . 4 . 5 . 7 2 . 9 LEF / . 9 LEF/ . 12 . 14 . 15 3 . 17 . 17 . 18 . 21 . 27 4 . 30 5 . 31 51 . 31 52 . 32 53 . 32 54 . 33 55 . 34 56 . 34 6. 35 61 . 35 62 . 35 63 . 36 64 . 36 65 . 38 . 39 LEF Series/ (ISO/IEC) (JIS)1)2) *1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

24 6CN1: . 25 6.1 . 25 6.2 . 25 6.3 . 26 1(C24V,M24V,0V) . 26 2(EMG) . 26 3LK RLS . 26 1 - 6.4 . 27 1 . 27 21 . 28 32 . 29 7DeviceNet 30 8LED . 31 8.1 LED . 31 8.2 LED . 31 9 . 32 9.1. . 32 9.2 No. . 32 9.3 / . 32 9.4 . 32 10 . 33 10.1 . 33 11 . 42 11.1 . 42 11.2 . 45 11.3 . 47 12 . 48 12.1 . 48 12.2 . 48 12.3 . 49 1 . 49 2 () . 49 3 . 49 12.4 . 50 12.5 . 50 13() . 51

./ . 44 15.1 . 44 15.2 . 45 15.3 . 46 15.4 . 47 15.5 . 48 15.6 . 48 16. . 49 2 - 16.1/ . 49 16.2 . 49 16.3 . 51 16.4 . 51 16.5 . 52 16.6 . 52 16.7 . 52 3 - LEC-G Series/ 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines