BBA4: For D-C7/C8/H7 The stainless steel bolts described above are used when the D-H7BAL type switch is shipped mounted on a cylinder.
BBA3: D-B5/B6/G5 types BBA4: D-C7/C8/H7 types "D-G5BAL" and "D-H7BAL"switches are set on the cylinder with the screws above when shipped. When a switch only is shipped, BBA3 or "BBA4" screws are attached.
Stainless steel mounting screw kit: BBA3 for D-B5, D-B6, D-G5, and D-K5 Stainless steel mounting screw kit: BBA4 for D-C7, D-C8, and D-H7 When the type D-H7BAL switch is shipped already mounted on a cylinder, the above stainless steel screws are used.
Flow Characteristics Port size Flow characteristics 1 2/4 (P A/B) 4/2 3 (A/B R) 1, 5, 3 4, 2 C [dm3/(sbar)] Cv b C [dm3/(sbar)] (P , EA, EB) (A, B) Cv b C4 0.14 [0.13] 0.26 [0.36] 0.58 [0.49] 0.18 [0.15] 0.15 [0.20] 0.76 [0.65] C8 C6 0.18 [0.16] 0.24 [0.27] 0.73 [0.64] 0.19 [0.19] 0.19 [0.16] 0.77 [0.74] M5 0.17 [0.15] 0.38 [0.35] 0.60 [0.57] 0.16 [0.16] 0.16 [0.39] 0.67 [0.58] Note)
(for 8) Series VQC1000 to 50 N9 (5/16") N1 (1/8") N3 (5/32") N7 (1/4") VQC101 1.0 0.65 Metal seal Rubber seal C10 (for 10) VQC200 C4 (For 4) C6 (For 6) C8 (For 8) 2.6 2.0 N11 (3/8") Series VQC2000 to 80 In case of branch type C12 (for 12) N13 (1/2") N3 (5/32") N7 (1/4") N9 (5/16") VQC201 3.2 2.2 C8 (For 8) C10 (For 10) C12 (For 12) Metal seal Rubber seal VQC400 Rc 1/2 6.9 6.3
BBA4: For D-C7/C8/H7 The stainless steel bolts described above are used when the D-H7BAL type switch is shipped mounted on a cylinder.
Flow Characteristics Port size Flow characteristics 1 2/4 (P A/B) 4/2 3 (A/B R) 1, 5, 3 4, 2 C [dm3/(sbar)] Cv b C [dm3/(sbar)] (P , EA, EB) (A, B) Cv b C4 0.14 [0.13] 0.26 [0.36] 0.58 [0.49] 0.18 [0.15] 0.15 [0.20] 0.76 [0.65] C8 C6 0.18 [0.16] 0.24 [0.27] 0.73 [0.64] 0.19 [0.19] 0.19 [0.16] 0.77 [0.74] M5 0.17 [0.15] 0.38 [0.35] 0.60 [0.57] 0.16 [0.16] 0.16 [0.39] 0.67 [0.58] Note)
PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.
Ports 2, 4 size (metric) Ports 2, 4 size (inch) Ports 2, 4 Symbol C3 C4 C6 C4 C6 C8 C6 C8 C10 C8 C10 C12 02 03 02F 03F M Ports 1, 3, 5 Applicable series Ports 1, 3, 5 Applicable series Ports 2, 4 Symbol 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting 8 One-touch
In this case, the U side supply/exhaust block will be a straight type C8. With upward facing elbow for the D side supply/exhaust block 35
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
One-touch fitting for6 VVQ1000-51A-C6 SY5000 One-touch fitting for8 VVQ1000-51A-C8 (Tightening torque: 1.4 N.m) Inch size Caution One-touch fitting for5/32 VVQ1000-50A-N3 SY3000 Note 1) When there are 10 or fewer manifold block assemblies, and more are added to make a total of 11 or more, a supply/ exhaust block assembly must also be added.
CE-certified Symbol EX124D-SMJ1-X182 CC-Link (Negative common) V A, B port size (Metric) A, B port size (Inch) P, E port Applicable series P, E port Applicable series A, B port Symbol C4 C6 C8 C8 C10 C12 M A, B port Symbol N3 N7 N9 N9 N11 M One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 A, B
Body ported For external pilot VV3Z5-21R-1 VZ52R 2.2 0.34 0.55 2.4 0.32 0.62 1/4 1/8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VV3Z5-41R-2 1/4 1/4 1/8 1/8 C6 C8 2.2 2.0 1.6 2.1 0.35 0.27 0.32 0.24 0.59 0.47 0.39 0.51 2.4 2.2 2.2 2.3 0.36 0.32 0.27 0.31 0.66
Applicable valve model Piping P, E port Port size Symbol VV3Z4-S50: only C6 & C8.
Stainless steel mounting screw kit: BBA3 for D-B5, D-B6, D-G5, and D-K5 Stainless steel mounting screw kit: BBA4 for D-C7, D-C8, and D-H7 When the type D-H7BAL switch is shipped already mounted on a cylinder, the above stainless steel screws are used.
Different sides Same side Different sides Same side 50 + 45 (n 2) (n = 2, 3, 4, 5 ) D-C7 D-C8 15 50 10 15 + 45 n 2 2 D-H7 D-H7W D-H7BAL D-H7NF (n = 2, 4, 6 ) 60 + 45 (n 2) (n = 2, 3, 4, 5 ) 15 60 10 Caution D-C73C D-C80C D-H7C 15 + 50 n 2 2 When operating a cylinder for the first time, make sure to release the air at low pressure.
) N7 N9 C6, C8, Directional Control Valves Air Grippers Modular F.
MB1 D-G5/K5/G5W/G5BA D-K59W, D-G59F, D-G5NT 20 to 100 D-C7/C8, D-C73C/C80C 20 to 63 CA2 CS1 Hs Hs CS2 24.5 16 A B B A D-B5/B6/B59W 20 to 100 D-H7/H7W D-H7NF/H7BA/D-H7C 20 to 63 Hs Hs 24.5 16 B A A B Auto Switch Mounting Height (mm) D-H7 D-H7W D-H7NF D-H7BA D-C7/C8 Auto switch model D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) D-G5NT D-G59F D-H7C D-G5BA D-C73C D-C80C
Pattern Air cushion None Size Thread type Attached C How to order model with auto switches Combination 4 Types Combination of Applicable Chart 10, 15 20, 30, 40 Size 10, 15 Port type Nil Nil TF TN TT Nil Chart 1, 2, 5 Chart 1, 2 Chart 2, 5 Chart 2, 5 C30 C8 C10 C30 C12 A2 A24 C11 C8 A1 A2 A14 A14 M5 Rc 1/8 G 1/8 NPT 1/8 NPTF 1/8 Refer to page 11-8-2 for How to Orderproducts with auto switch