SMC Corporation of America
Elite Part Number Search
Search Results "VH302-03-L"

L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

/min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min VCB 3 Cv = 0.35 3 4 Formula based on effective area (Smm) 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24

Stainless Steel (mm) A B C D E F G H J L Bracket part no.

L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -31- Recommended Value of acceleration time constant of Point table No.1 [LEY] LEY25

O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.

Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399 388 L1 L2 3-2-7 Series VK3000 Base mounted (Bottom ported) Type 40 Manifold Grommet: G DIN terminal: D VV5K3-40Station -M5 ( ) ( ) ~ = L Dimension n: Stations n L 1

.: 3.5 to 7 78.4 Max.10 74.1 70.9 Manual override (Non-locking) Pg7 2 x 4.5 (Mounting hole) n2 x Rc1/8 (A port) 11 2B 4A 2A 2B VV061 38 4A 2A 19 VV100 3 (Pitch) 2 x Rc1/8 2 x Rc1/8 V100 (P port) (P port) 2n1 x Rc 1/8 (A,Bport) (Lead wire length) S070 n1 = Number of VK3000 n2 = Number of VK300 ~ = 300 VQD VQD-V VK VK 2n x M5 x 0.8 (R1, R2 port) (Pitch) VT L Dimension n: Stations n L 1 38 27

B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL. A 6 Station 8 SOL.

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket:

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -28- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket

: °C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.

O.D: 3.5 to 7 Max.10 69.8 83.4 75.9 2 x 4.5 (Mounting hole) Manual override (Non-locking) Pg7 300 (Lead wire length) 4 x Rc 1/8 (P, R port) 4 x Rc 1/8 (P, R port) 2 x 4.5 (Mounting hole) 39 23 8 (Pitch) 1.5 10.5 49.5 (Station 1) (Station n) 4 x M3 x 0.5 depth 6 (Bracket mounting screw) (Pitch) n x Rc 1/8 (A port) L Dimension n L n: Stations 1 37 27 20 398 388 13 32 51 70 89 108 127 146 165

: °C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)