SMC Corporation of America
Elite Part Number Search
Search Results "VG342R-5DZ-06-M-X87"

Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4)

Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4)

Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)

Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4)

Pressure Specifications: 1 [-101 to 10kPa (for vacuum)], One-touch Fitting Type: ø6mm, KJH06-M5, Option, Case Holder: Without case, Unit Specification: Fixed in SI Unit

Pressure Specifications: 0 [-0.1 to 1MPa (for high pressure)], One-touch Fitting Type: 06 (ø6mm, KJH06-M5), Option, Case Holder: Without case, Unit Specification: M (Fixed in SI Unit)

Pressure Specifications: 1 [-101 to 10kPa (for vacuum)], One-touch Fitting Type: 06 (ø6mm, KJH06-M5), Option, Case Holder: Without case, Unit Specification: M (Fixed in SI Unit)

Type: -, Maximum Indicated Pressure(Mpa): -, Connection screw: Single-action fittings, Option: None, Indicated Pressure Range: -0.1 to 1 MPa, Pressure Specifications: For high pressure, Applicable Tube Size: ø6, Unit Specifications: SI unit fixed

./ Port size Connection Symbol A10 A14 B5 M5 x 0.8 Pad type B01 Rc 1/8 Female thread Vacuum entry F Ball joint type N01 NPT 1/8 T01 NPTF 1/8 04 4 tube Material One-touch fitting 06 6 tube N NBR 08 8 tube S Silicone rubber Tightening torque (N m) U Urethane rubber F FKM Torque Mounting thread dia.

L D-A73 (Example) CLQ Lead wire length MLGP 5 m None Nil L 0.5 m 3 m Z N RLQ Applicable for the connector type (D-C) only.

(Default settings) Base mounted Solenoid Specifications Grommet (G), (H), L plug connector (L), M plug connector (M), DIN terminal (D), (Y), M8 connector (W) Symbol Electrical entry Internal pilot G, H, L, M, W D, Y 10-SYJ51 M 2 4 10-SYJ52 M 2 4 DC AC 50/60 Hz Coil rated voltage (V) 24, 12, 6, 5, 3 24, 12 2(A) 2(A) 100, 110, 200, 220 10% of rated voltage Allowable voltage fluctuation Standard

cable L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) M: Common exhaust for the pilot and main valve + + + D: Push-turn locking slotted type + R port P, E port H: Lead wire length 600 mm Pilot valve exhaust is centralized to main valve.

Bore size [mm] Dd9 L l m d Part no.

Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101

Load factor: ((Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Base mounted Tubing bore x Length Speed controller Silencer Body ported Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 SYJ3140-M5 SYJ3120-M3 2 Series SYJ3000 How to Order Light/surge voltage suppressor Bracket

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 The 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Base mounted Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 Body ported Tubing bore x Length Speed controller Silencer SYJ3140-M5 SYJ3120-M3 1-5-5 Series SYJ3000 How to Order Light/Surge voltage suppressor Bracket

Body O.D.:98 06 Rc3/4 10 Rc1 Model Port size Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 XTO-2571 XTO-1239 XTO-1719 Dimensions: mm ASP-X369 Series Applicable tubing O.D.d D2 Laser printed T2 (Pilot port) 3 H1 (Hexagon width across flats) H2 (Hexagon width across flats) A L4 D1 L3 T1 (With sealant) M L1 L2 *Reference dimensions after A thread installation.

N P U T S R VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 VFN 1 4, 3 8, 1 2 64 64 65 70 1 136 35 9 64 54 19 32 50 50 118 96 120 60 7 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 133 96 140 66 9 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 64 50.8 163 196 68 60.5 1 2, 3 4 4-16-7