W Recommended Pneumatic Equipment CC Brake valve VFS21O VFS21O VFS21O VFS31O VFS31O Bore size (mm) Directional control valve VFS24OR VFS24OR VFS34OR VFS44OR VFS44OR Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Speed controller AS4000-02 AS4000-02 AS4000-03 AS420-03 AS420-04 Regulator AR425 AR425 AR425 AR425 AR425 Piping Nylon 8/6 or larger Nylon 10/7.5 or larger Nylon 12/9 or larger
The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the product. Do not perform wiring while the power is on.
No.IP8S-OM09 33 (on) and (oFF) of forced fully-close / fully-open setting can be set independently for fully-close side and fully-open side. (on) is set for fully-close setting and fully-open setting for the default value at ex-factory.
Fig. 33 No.DIG-31900-OM002 39 Parameter Setting Procedure This parameter is fixed when shipped out of the factory. User can not change it. (000) Actuator type (200) Operation direction Customer can select direct (dir) or reverse (rvs).
[SW] 1 1 1 ( ) ( ) 0. [] 02 1. a [a ] 2. b [b ] SW 21 21 1 33 - 8. 8.1 ( ) () M 8.2 0 () /() M 34 - 8.3 1 (1) INP ON (/) M (2) () INP OFF (3) INP OFF INP ON 35 - INP ON ( ) 8.4 PLC 15ms 30ms 8.5 2 EMG EMG OFF () RESET RESET () HOLD HOLD EMG RESET OUT OFF 36 - 9. () 9.1 )100mm/s 50mm (No.1 ) 50mm/s 50mm 10mm 5 100mm (No.2 ) No. 1 2 2 2 mm/s mm mm/s mm/s mm mm mm
[SW] 1 1 1 0. [] 02 1. a [a ] 2. b [b ] SW 21 21 1 33 - 8 81 ( 82 0 / 34 - 83 1 1 INP ON / 2 ( INP OFF 3 INP OFF INP ON 35 - INP ON ( ) 84 PLC 15ms30ms 85 2 EMG EMG OFF () RESET RESET () HOLD HOLD EMG RESET OUT OFF 36 - 9 91 )100mm/s 50mm (No.1 ) 50mm 50mm/s 10mm 5 100mm (No.2 ) No. 1 2 2 2 mm/s mm mm/s mm/s mm mm mm mm/s 0 1 ABS 100 50.00 1000 1000 0 0 0 100
LEC . 8 (4)GW . 8 (5)GW . 8 (6) . 9 (7) . 9 3 . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGEN1) . 13 (2)DIN (LECGEN1D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1GW (B RATE) . 15 4.2 (CN2SW) . 16 4.3LEC . 16 4.4GW EtherNet/IP . 22 5. . 26 5.1 CN4 . 26 5.2 CN3 . 26 5.3 CN1CONT . 26 5.4 CN2PC/TB . 27 6.CN4 . 28 1 - 6.1 . 28 6.2 . 29 6.3 . 30 . 30 7.CN1(CONT) . 31 7.1 . 31 7.2 . 33
Replace the O ring, the gasket, and the element with new parts. 4.6-33
Weight 12 mm or less 32 g 15-6-33 1 Related Products: Tube Releasing Tool Series TG For attaching and dettaching tubes for One-touch fittings mounted in a narrow space or on manifolds. Easy one-hand operation Available for two sizes of applicable tubes. Exchangeable easily with one hand.
NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 5 13 15.0 12.5 M8 x 1.25 32, 40 8 22 25.4 21.0 M14 x 1.5 50, 63 11 27 31.2 26 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.
Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. Caution Warning How to Wire The DIN Connector Manual Override ISO#: Based on DIN 43650C (Pin gap 8mm) Connection Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve.
Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. How to Use Plug Connector Manual Operation Warning Caution SY Installation and removal of connector Connected actuator is started by manual operation. Use the manual override after confirming that there is no danger.
Rubber seal 16.2 (0.9) VQZ332 33 or less 25 or less 92 VQZ300 Metal seal 13.5 (0.75) VQZ322 22 or less 17 or less N.O.
*{b-40-**+-'o.or 1 : rN)c0r 80 1oo tlnJ' -*--*-*--33 13 = cQ2L:s 5 s'F ."-"c" :^''^" *'."' -.t;^'."d;-:.df o,r's!.4 d.!
Stations 1 2 3 4 5 6 7 8 9 10 ZZM-CR-01 ZZM-CR-02 ZZM-CR-03 ZZM-CR-04 ZZM-CR-05 ZZM-CR-06 ZZM-CR-07 ZZM-CR-08 ZZM-CR-09 ZZM-CR-10 SP ZCUK AMJ AMV AEP (2) (3) HEP Note Quantity Adapter A Adapter B Silencer Blanking plate No. 1 2 3 4 5 6 7 8 9 10 11 Model ZZM-SA ZZM-BP ZZM-ADAZZM-ADBZZM-GE ZZM-EPLZZM-GBL ZZM-GBB ZZM-GBR ZZM-EPRZZM-CRDescription 2 1 1 Station: 1 1 1 1 Manifold part no.
. ## Description 00 Set to the test operation mode. 01 Station number 1 02 Station number 2 03 Station number 3 : : : : 62 Station number 62 63 Station number 63 64 Station number 64 Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number. 3. indicates the warning/alarm No. 4. Requires set up software(MR Configurator2TM) . -11- 3.
Specification 33 8.1. Dimensions 33 8.2. Specifications 34 9. Accessories 35 10. Troubleshooting 41 -2No.EX-OMY0014-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".
No.EX-OMN0013-I PRODUCT NAME SI unit for DeviceNet MODEL / Series / Product Number EX260-SDN# Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 DeviceNet Objects 20 Troubleshooting and Maintenance 28 Specification 33 Specifications 33 Dimensions 35 Accessories
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 8 9.2 6 15.5 5 9.2 M5 x 0.8 4 10 20.5 10 8 8 9.2 8 16.5 6 11.5 M6 x 1.0 5 16 22.5 16 10 8 9.2 10 18.5 6 15 M8 x 1.25 5 20 24.5 20 13 10 11.5 12 22.5 11 19.6 M10 x 1.25 6 25 33.5 25 17 14 16 16 28.5 12 25.4 M14 x 1.5 8 30, 40 40.5 30, 40 22 Applicable bore size (mm) Part no.