1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N NPT1/8 2 01F G1/8 M5 M50.8 M50.8 M-5P ZB03 ZB04 ZB05 ZB06 PV N.C.
(Fill out for I/O unit only) 01 1 station Nil PNP (+) or without SI unit/input block(SD0) NPN () N The maximum number of stations differs depending on the electrical entry.
-30 to 180 F Performance Data 90 PS Swivel 150 SUS Oil Flow vs.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A AS Series Speed Controller: Standard Type In-line Type Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
VC Model VDW VQ Thread type Nil T F N Orifice size Rc NPTF G NPT 1 2 3 4 1.5 mm 2.2 mm 3 mm 4 mm VX2 VX Refer to the table (1) given below for availability. VX3 Port size 01 02 03 1 8 1 4 3 8 VXA Valve/Body 4 Common/Single unit Refer to the table (1) given below for availability.
Port size Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Plug Yes No No Yes Socket Yes Yes No No Availability Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.
AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
Items don't need to be changed in positioning operation. a < Movement Method> When the absolute position is required, set Absolute Position Accel Decel Pushing F TriggLV Moving F Area 1 Area 2 In pos No.
Contact SMC regarding the specifications for PSI unit and F .
Six station manifrcld ass'y: sta. 1-4) NVF'I'10-5G-017 sta. 5-6) NVF1 10-3G-017 NW3F1 -30-061-017 No. ot Stgliorg I l 5 I F Mounting Brackets tPoding 01 ,d' NPIF DltrlENSlON D E F G H J x ll ta o P n s T u w x z AA BB 3.78 (96) 3.41 1.77 (,r5)0.39 (10) o.59 (15) 0.20 (5) 0.63 (16) 1.O2 (28t 3.50 (89) 1 . 1 8 (30) 0.59 (15) 2.76 (70) o.87 (21) o_20 {5) 1 . 1 8 {30} 0.67 ltTl 0.59 (ls) o.32
AF-OMX0054-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AFD20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFD30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
Six station manifrcld ass'y: sta. 1-4) NVF'I'10-5G-017 sta. 5-6) NVF1 10-3G-017 NW3F1 -30-061-017 No. ot Stgliorg I l 5 I F Mounting Brackets tPoding 01 ,d' NPIF DltrlENSlON D E F G H J x ll ta o P n s T u w x z AA BB 3.78 (96) 3.41 1.77 (,r5)0.39 (10) o.59 (15) 0.20 (5) 0.63 (16) 1.O2 (28t 3.50 (89) 1 . 1 8 (30) 0.59 (15) 2.76 (70) o.87 (21) o_20 {5) 1 . 1 8 {30} 0.67 ltTl 0.59 (ls) o.32
Front In measurement mode, when the button is pressed for 2 seconds or longer, [F 0] is displayed. This [F ] indicates the mode for changing each functional setting. Press the button for 2 seconds or longer to return to measurement mode. 2. [P_1] or [n_1] and the set value are displayed alternately.
(F, P kit) Top entry Side entry Replaceable One-touch fittings Single mounting screw, clamp construction SI unit for I/O (DeviceNet, PROFIBUS-DP, CANopen, AS-i, etc.)
Contact your sales representative tor further details. .f f'' r'r *x , r:r,r..t :':,:':,t Simple maintenance and overhauling It is easy to disassemble and simple to release lock-up unit by manual override.
rated pressure range, Ambient temperature 25 3C) Linearity 1% F .S. or less Repeatability 1% F .S. or less Power supply voltage effect 1% F .S. or less based on the analog output at 18 V ranging from 12 to 24 VDC Enclosure IP40 Temperature range 0 to 50C; Stored: 10 to 70C (No freezing or condensation) Resistance Withstand voltage 1000 VAC, 50/60Hz for 1 minute between external terminals
Contact your sales representative tor further details. .f f'' r'r *x , r:r,r..t :':,:':,t Simple maintenance and overhauling It is easy to disassemble and simple to release lock-up unit by manual override.
Standard Small lK)lnt Q f contacl f!)$utls In 1 8% 1 1'11:11011. The figure a seal vent $MC PneumatICS' unique figure 8 seal incorporales vents that allow pressufized air to flow into an Integrated cavity forcing the seal firmly against the opposite side 01 the piston seal groove creating a much tighter, more positive barrier against leakage.
Alarm1 Water Leak Detect FLT 01 Alarm2*1 02 Alarm3 RFGT High Press FLT 03 Alarm4*1 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.