VAC, 220 VAC, 230 VAC, 240 VAC (50/60 Hz) Rated voltage 200 VAC, 220 VAC, 230 VAC, 240 VAC (50/60 Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Class B VCL20: 6 W, VCL30: 8 W, VCL40: 11.5 W Power consumption DC VCL20: 22/19 VA VCL30: 36/30 VA VCL40: 45/37 VA Note 2) Inrush VCL20: 8.5 VA VCL30: 10 VA AC 50/60 Hz Apparent power VCL20: 10/8 VA VCL30: 15

Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical

N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.

Table 8-1 Quality criteria for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

JX C 9 1 () LEFS16B-100B-S1C917 [LEFS16B-100] 9 EtherNet/IP 1 1 DC24V 7 8 DIN <> LECPMJ SVRE X1.5 -7- 2.3 *1 EtherNet/IP PLC P1P2 P5062-5 *1 () LE-CP-() LE-CP---S () LE-CP-* ENC *2 SI MOT 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 PWR DC24V USB (A-miniB type) () JXC-CPW <> ( USB ) LEC-W2 (3m) AWG20(0.5mm

LE C A 6 N A (DC24V) (LE ) LESH16RAJ-50BS-R16N1D 6 64 LESH16RAJ-50 I/O N NPN DIN P PNP 1 1.5m D DIN 3 3m 5 5m <> NPNPNP LESH16RAJ-50 NPN NPN 7 - 2.3 1 I/O LEC-CN5-* PLC 1 3 DC24V CN5 CN3 CN4 2 1 () LE-CA-* CN2 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 3 50 200 50 200 3 3 CN1 DC24V <> AWG20 (0.5mm 2) USB A-miniB type USB LEC-W2

200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 *3 DC24V USB A-miniB type CN1 <> ( 2) AWG20 (0.5mm (3m) USB ) LEC-T1-3G LEC-W2 *1 *2 http://www.smcworld.com/ *3 UL ,UL1310 Class2 *4 5.

JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200

Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Nil 6 10 15 20 25 30 50 G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire

(Refer to page 40, 41) [EXA1-30] 10 to 1050 L/min [EXA1-30] 50 L/min Common Standby flow rate (Threshold) [EXA1-40] 20 to 2100 L/min [EXA1-40] 100 L/min Common [EXA1-60] 40 to 4200 L/min [EXA1-60] 200 L/min Common [EXA1-20] 0 to 520 L/min [EXA1-20] 50 L/min Common Sets the standby flow rate (hysteresis).

5 Pilot valve assembly How to Order Pilot Valve Assembly SCZ2 G 1 1 Rated voltage Series VZ200 1 100 VAC, 50/60 Hz Pilot pressure exhaust Manual override Electrical entry 2 200 VAC, 50/60 Hz 1 Spacer side exhaust (Type 20) 3 110 VAC, 50/60 Hz Nil Push type (Safety style) G H L LN L plug connector With lead wire 600 mm lead wire 300 mm lead wire 4 220 VAC, 50/60 Hz Grommet B Locking type

Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable

Model RZQ32 RZQ40/50 RZQ63 Applicable floating joint JB40-8-125 Graph (1) JB63-10-150 200 JB80-16-200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 100 Guide Shock absorber 50 Load weight (kg) 50 40 40 32 30 Floating joint 3 position cylinder 20 10 Maintenance

H 4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 consumption (W) Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.

/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.

74 60 820 263 86 70 0.05 AN300-03 3 8 AN400-04 1 2 0.02 AN500-06 3 4 0.01 AN600-10 1 1 1 0.005 AN700-12 1 4 AN800-14 1 2 AN900-20 0.002 50 200 1000 5000 20 100 500 2000 10 50 10 Construction/Parts/Dimensions Air flow (l/min (ANR)) AN500 to 900 AN200 to 400 Noise Level (Initial conditions) End plate End plate AN200 to 900 Condition: 0.5 MPa at inlet pressure of solenoid valve Measurement

400, 450, 500 CA2 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper -XC5 Heat resistant cylinder (10 to 110C) -XC6 Made of stainless steel*3 *4 Up to 2700 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC7 Tie-rod

/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.

/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.

Model RZQ32 RZQ40,50 RZQ63 Applicable floating joint JB40-8-125 Graph 1 JB63-10-150 200 JB80-16-200 63 100 Guide Shock absorber 50 Load weight (kg) 50 40 40 32 30 Floating joint 3 position cylinder 20 10 Maintenance Caution 5 150 100 200 300 1.