Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 0.805, Torque(N⋅m): 3.14,
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820, Torque(N⋅m): 10.8
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.048, Format: Includes adjusting bolt, Size: 30, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Valves: Not Provided, Allowable Kinetic Energy(J): 0.007, Format: Includes adjusting bolt, Size: 10, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.039, Format: With internal shock absorber, Size: 10, Switch: A93, Lead wire
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.025, Format: Includes adjusting bolt, Size: 20, Switch: A93, Lead wire(m)
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.116, Format: With internal shock absorber, Size: 20, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.048, Format: Includes adjusting bolt, Size: 30, Switch: A93, Lead wire(m)
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.116, Format: With internal shock absorber, Size: 30, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.081, Format: Includes adjusting bolt, Size: 50, Switch: A93, Lead wire(m)
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.294, Format: With internal shock absorber, Size: 50, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.240, Format: Includes adjusting bolt, Size: 70, Switch:
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.100, Format: With internal shock absorber, Size: 70, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.320, Format: Includes adjusting bolt, Size: 100, Switch:
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.600, Format: With internal shock absorber, Size: 100, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.560, Format: Includes adjusting bolt, Size: 200, Switch:
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 2.9, Format: With internal shock absorber, Size: 200, Switch
Sensor Type: Contacting, Output Format: NPN Format, Wiring Method: 3-Wire, Type: Main Body, Lead wire length(m): 3, Applicable load: Relay / PLC
The RSQ series is a fixed-height stopper cylinder with proven endurance and low breakaway characteristics. The RSG series is an adjustable mounting height stopper cylinder. It can be raised or lowered according to the distance required to stop the work piece. The RSH heavy-duty stopper cylinder is specially designed for use on conveyor lines or other applications requiring an external stopping
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 50MM RSQ DBL-ACT AUTO-SW, ACTUATOR, RSQ/RSA MISC/SPECIALIZED, NE, 50MM RSQ DBL-ACT AUTO-SW