SMC Corporation of America
Elite Part Number Search
Search Results "NALT-5-IS-1"

7 @5 #6 #3 #2 !9 #4 #5 #1 MY CY @7 @8 t @9 @4 @4 @4 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX DMetal stopper Shock absorber e !8 A -X i !1 !0 @6 o @0 20Data !3 !4 !5 !6 !2 @2 @1 Detail drawing of part A Component Parts Note Note Material Material No.

Connection thread size R, Rc Series Connection type 3/8 1/2 5/16" 1/4" 3/8" 1/2" 1/8 1/4 Male thread type Female thread type Barb fitting type KK13 Also available with G threads. Compact with High Flow Rate Series KK S Couplers No spring located in the flow path Loss of effective area is minimized because there is no valve spring to block the flow path.

Flow Direction Symbols on Body Flow Rate and Effective Area Meter-out type Meter-in type AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS121F AS131F Model Symbol JIS Symbol Metric size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled

D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.

Hardware failure) 3 3 4 5 4 1 3 IRELAND (353) 1 403 9000 W-SS OFF Power supply for control and input (US1) is not supplied.

Stations t Bottom porling spscmcabn wilh 'r02T is 1," qA,B boitom and 1/4'A,B side.

(Crimping tool: DXT170-75-1) Misc. Power Supply Warning 1. Vacuum pressure switch: The performance is not affected even if a momentary pressure of approximately 0.5 MPa is applied (during a vacuum break). However, make sure that a constant pressure that is higher than 0.2 MPa is not applied.

When wiring is done at the factory, positive (+) is red and negative (-) is black. With power saving circuit (JSY3000/5000: Made to Order) Power consumption is decreased to approx. 1/2.5 to 1/4 of the amount consumed at startup by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 62 ms at 24 VDC.)

4 3 8 3 4 1 2 ITV / 1 3 4 1 VBA 2 1 1 2 /1 1 4 VE Dimensions: Auto Feed Tank VY G AL L K 428 428 J 414 414 472 472 I 382 382 422 422 H 24 24 40 40 G 197 197 258 258 F 106 106 137 137 E 91 91 121 121 D 7 7 7 7 C 16 16 30 30 B 70 70 108 108 Model A 174 174 234 234 ALT-5 ALT-5-IS ALT-9 ALT-9-IS 449 482 1.17-14 Oil Distributor VA, VB/Nylon Tubing Related Products Oil Distributor Series VA, VB

Note 1) The tightening torque for the hexagon socket head cap screw (M3 x 14 L) is 0.5 to 0.6 Nm. Note 2) The tightening torque for the hexagon socket head cap screw (M2.5 x 5 L) is 0.25 to 0.35 Nm.

Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.

Forced output mode. 3 2 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3, France 2 24 V (Output) 2 24 V (Output) 1 2 OFF Base is not registered. 4 5 4 1 0 V (Control and input) 3 0 V (Control and input) Green LED is ON. Remote is normal. 3 3 SF Base system status Red LED flashes. Restorable error is detected.

year or when a pressure drop of 1 Bar is reached.

Flow Rate and Sonic Conductance AS121F-M3 AS121F-M5 AS131F-M5 AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS131F-M3 Model AS121F-M5-02 2, 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Metric size Tubing O.D. 1/8" , 3/16" 1/8" , 5/32" 1/8" , 5/32" 3/16" , 1/4" , 1/4" , 5/16" , 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled

M48 x 2 How to Order Type C1 (Clear cover is removable.) G E M 10 01 C 46 Attachment (Cover ring assembly) 5 Symbol Specifications Connection thread Size M5 x 0.8 x 5 Pressure gauge Without cover ring assembly Nil Size Symbol Clear cover has no protrusion. (Clear cover is irremovable.) Outside diameter C Symbol 46 42.5 01 R 1 8 02 R 1 4 Clear cover has protrusion.

32UNF KJW03-32 7 8.9 17.5 25.5 27 14.5 2.3 6.4 5/32 10-32UNF KJH03-32 8 18.5 15.5 2.3 2.4 5/32 1/16 KJW03-33S 9.5 8.9 17.5 25.5 26 14.5 2.5 8.7 5/32 1/16 KJH03-33S 9.5 22 18 3 5.2 5/32 1/8 KJW03-34S 11.11 8.9 17.5 25.5 26 14.5 2.5 10.6 5/32 1/8 KJH03-34S 11.11 17.5 13.5 3 5.1 1/4 10-32UNF KJW07-32 7 11.9 17.5 27 30 15.5 2.3 7.3 1/4 10-32UNF KJH07-32 20.5 17.5 2.3 5.1 1/4 1/16 KJW07-33S 9.5

8 ) 35 + 30 (n 2) (n = 2, 3, 4 ) Different surfaces D-A44 90 + 50 (n 2) (n = 2, 4, 6, 8 ) 75 + 50 (n 2) (n = 2, 4, 6, 8 ) 80 + 50 (n 2) (n = 2, 6, 8 ) 55 + 50 (n 2) (n = 2, 3, 4 ) Same surface 75 80 1 pc. 90 10 Note 1) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.