Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV
Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.
Magnet: D (Built-in), Series: A2 (Standard), Mounting: F (Rod Flange), Tube Material: Aluminum, Bore Size: 100mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: None, Series: A2 (Standard), Mounting: G (Head Flange), Tube Material: Aluminum, Bore Size: 40mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in), Series: A2 (Standard), Mounting: D (Double Clevis), Tube Material: Aluminum, Bore Size: 100mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in), Series: A2 (Standard), Mounting: F (Rod Flange), Tube Material: Aluminum, Bore Size: 80mm, Port Thread: TN (NPT), Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in), Series: A2 (Standard), Mounting: G (Head Flange), Tube Material: Aluminum, Bore Size: 100mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in), Series: A2 (Standard), Mounting: L (Axial Foot), Tube Material: Aluminum, Bore Size: 40mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in), Series: A2 (Standard), Mounting: G (Head Flange), Tube Material: Aluminum, Bore Size: 63mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion
Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: N (Rubber Bumper), Bore: 32mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot
Magnet: None, Mounting: B (Basic), Bore Size: Ø100, Port Thread: TN (NPT), Stroke: 400mm, Option: w/o Rod Boot
Magnet: None, Mounting: L (Foot), Bore Size: Ø100, Port Thread: TN (NPT), Stroke: 400mm, Option: w/o Rod Boot
Magnet: None, Mounting: B (Basic), Bore: 63mm, Port Thread: TN (NPT), Stroke: 400mm, Cushion: Rod Boot None; Air Cushion on Both Sides
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc