) P, S, T Internal speed limit 1 T PD09 *DI4-1 Input signal device selection 4L (CN1-6) P, S, T PC07 SC2 Internal speed command 2 S PD10 *DI4-2 Input signal device selection 4H (CN1-6) P, S, T Internal speed limit 2 T PD11 *DI5-1 Input signal device selection 5L (CN1-7) P, S, T PC08 SC3 Internal speed command 3 S PD12 *DI5-2 Input signal device selection 5H (CN1-7) P, S, T Internal speed
C85NT08A-S C85NT10A-S C85NT10A-S C85NT20A-S C85NT25A-S Mounting nut C85NT08B-S C85NT08B-S C85NT10B-S C85NT10B-S C85NT20B-S C85NT20B-S C75 Standard C75 Double acting, Single rod C75W Double acting, Double rod C75 Single acting (Spring return/extend) Direct mount C75R Double acting, Single rod XC6A only Description Bore size [mm] 32 40 Rod end nut C76NT32A-S C76NT40A-S Mounting nut C76NT32B-S
(Single acting/Spring extend) Bore size (mm) 1 2 12 16 20 25 32 40 50 CQ2B12-S-PS CQ2B16-S-PS CQ2B20-S-PS CQ2B25-S-PS CQ2B32-S-PS CQ2B40-S-PS CQ2B50-S-PS CQ2B12-T-PS CQ2B16-T-PS CQ2B20-T-PS CQ2B25-T-PS CQ2B32-T-PS CQ2B40-T-PS CQ2B50-T-PS Piston rod 3 Collar 4 Retaining ring Bushing Return spring Bronze element Retaining ring Plug with fixed orifice Steel ball 5 6 7 8 9 10 11 12 13 14 15 16
1 A Q a q 0 0 1 0 2 STX DC2 2 B R b r 0 0 1 1 3 ETX DC3 # 3 C S c s 0 1 0 0 4 $ 4 D T d t 0 1 0 1 5 % 5 E U e u 0 1 1 0 6 & 6 F V f v 0 1 1 1 7 7 G W g w 1 0 0 0 8 ( 8 H X h x 1 0 0 1 9 ) 9 I Y i y 1 0 1 0 10 : J Z j z 1 0 1 1 11 ; K [ k { 1 1 0 0 12 , L l | 1 1 0 1 13 M ] m } 1 1 1 0 14 . N ^ n 1 1 1 1 15 / ?
MY1B32-500 Average operating speed a 300mm/s Mounting orientation .. Horizontal mounting 1. Horizontal mounting 2. Wall mounting P. 58 z y x y x z W: Work piece (2kg) 3. Ceiling mounting P. 42 4.
hole to through-hole W, S, J, K, T, Y XC3 Change the screw position W, S, J, K, T, Y XC4 Change the rotation range W, S, J, K, T, Y XC5 Change rotation range between 0 to 200 W, S, J, K, T, Y XC6 Change rotation range between 0 to 110 W, S, J, K, T, Y XC7 Reversed shaft W, J XC30 Fluorine grease W, S, J, K, T, Y X5 For M5 port (90/180) W, S, J, K, T, Y Rotation time adjustment range s/90
If the leakage volume is 30 L/min (ANR), the vacuum pressure of the S type is 20 kPa q w e, and for the L type it is 33 kPa q' w' e'. If the leakage volume is 5 L/min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'.
Driver Driver Servo amplifier Servo motor Servo amplifier Servo motor U U U U CAUTION V V M V M V W W W W Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the driver may cause a malfunction. 3 3 3.
/s 100 mm/s or more y Follow-up speed Less than 100 mm/s Low adhesion Required w Required w Low adhesion Required w Low adhesion Not required (Except CJ2X and CUX10) Not required Not required q q qr 1 Consider using the smooth cylinder. 2 Consider using the low speed cylinder (new model). 3 Consider using the low speed cylinder (conventional model). 4 Consider using the low friction cylinder
Basic circuit 1) [Horizontal] SOL.C Forward SOL.B W Action SOL.A SOL.B SOL.C Forward SOL.B ON ON OFF Backward OFF OFF OFF Locked stop 0.5 s or more Regulator with check valve SOL.A SOL.C ON OFF OFF Unlocked SOL.A W 3 port normally closed 0 to 0.5 s Forward ON ON OFF Pressure center ON OFF ON Backward SOL.C SOL.B OFF OFF OFF SOL.A Locked stop 0.5 s or more ON OFF OFF Unlocked 0 to 0.5 s ON
: 10, 15 90 CDRBU2 W U 10 180 S With auto switch Size: 20, 30, 40 CDRBU2 W U 20 180 S R73 Number of auto switches With auto switch Size S Nil 1 pc.
(g) n: Number of stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For 10 stations or more (5 stations or more in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA and EB ports on both sides.
N ever t urn t he ri ght angl ed t ype connect or as i t i s not desi gned t o t urn. Brow n Pow er suppl y N ot e) The w i re col or i s f or w hen opt i onal cabl e i s used.
A R B F I T T I N G F O R S O F T T U B E: M-3AU-4 M-5AU-4 M-5AU-6 B A R B E L B O W F O R S O F T T U B E: M-3ALU-4 M-5ALU-6 U N I V E R S A L E L B O W: M-3UL M-5UL 18 female diverted to 9 x M5 MORE SELECTIONS S E E N E X T P A G E P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R H O W T O O R D E R S E E N E X T P
EX124D-SMJ1] Note 1) U S U S e w AXT100-1-P Note 2) U S U S SYJ AXT100-1-F Note 2) Note 1) Dust-tight, Water-jet-proof (IP65) Note 2) Top entry connector for FU, PU while side entry connector for FS, PS.
200 W 400 W 100 W 200 W 400 W Type AC servo motor (S2) AC servo motor (S3) AC servo motor (S4) AC servo motor (S6) AC servo motor (S7) AC servo motor (S8) C S1 S3 S41 SSCNET III type (For absolute encoder) Incremental S S5 S7 S81 Power supply voltage Absolute 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz 1 Not applicable for Series LEY Dimensions LECSAm 40 135 2 x 6 Mounting hole
0 Port plugs> CP F kit P kit (26P) P kit (20P) J kit (20P) L kit S kit Nil E F0 P0 PC0 J0 Nil S0 DIN rail mount type Direct mount type q VVQZ2000 w
Find the value of Wmax when Va = 300 mm/s from Graph (1). L2 L1 xStatic moment Examine M2. Since M1 & M3 are not generated, investigation is unnecessary. M2 = W L1 = 10 0.05 = 0.5 [Nm] 2 = M2/M2 max = 0.5/16 = 0.031 W = 1 [kg] = 10 [N] W M Find the value M2 max when Va = 300 mm/s from Graph (3).
Dimensions: Without Buffer ZP2-R W-A5 04 06 ZP2-R 20 W-A5 04 06 ZP2-R 30 W-A5 04 06 Width across flat 8 (Hexagon) Width across flat 8 (Hexagon) Width across flat 8 (Hexagon) Width across flat 10 (Hexagon) Q Q Q Width across flat 10 (Hexagon) Width across flat 10 (Hexagon) 4 4 4 4 4 4 21 21 21 M5 x 0.8 M5 x 0.8 M5 x 0.8 P P P (60) (60) (60) S S 31 8 31 S 31 14.9 A 14.9 14.9 R R R 6 6 6 M5