SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-T-01"

Model Description AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 G36-10-01 G46-10-02 Gauge (5) 1.0MPa Accessories (Options)/Part No.

Related Products/Tubing: Nylon, Soft Nylon, Polyurethane How to Order Tubing Use the kind of tubing indicated at the right for suction filter with one-touch fitting (Series ZFC). 0604 20 B T Refer to Best Pneumatics No. 6 for details on valves.

ZS-32-A ZS-32-D Refer to Best Pneumatics No. 8 for Pressure Switch Precautions, and the Operation Manual on SMC's website for Specific Product Precautions. 734 Compact Manifold Regulator ARM11A/B Series Common Supply Block ARM11A 1 S 01 3 Z A q w e r t y ARJ AR425 to 935 1. IN Piping Position 2.

B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL. A 6 Station 8 SOL.

2 IN OUT IN OUT u r t i u r t i Component Parts Material AWG20K AWG30K AWG40K Note No. Description Body 1 ZDC ADC Platinum silver Bonnet 2 PBT Black Handle 3 POM Black Replacement Parts Part no. AWG20K No.

Diaphragm material 1 VXA PTFE (Fluoro resin) JIS Symbol Style VN Port size 1 3 Built-in solenoid valve Air operated LVC 01 1/8 (6A) FLUID OUT AIR SUP AIR EXH LVA Thread type FLUID IN Nil T Rc NPTF G NPT LVH Built-in solenoid valve F LVD N T, F, N are options.

While its lighting, output ranges of OUT1 and OUT2 are adjustable. y u t r Adjusts the sensor unit at the time of connection. Once adjusts, no need to re-adjust as long as the sensor unit is not replaced. Adjustment must be undertaken while the sensor unit is removed from the actuator. Refer to the operation manual for details.

Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data

Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMZ0024 Data

V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C () () UP SET DOWN OUT1OUT2 ON UP ON/OFF SET DOWN ON/OFF -12No.PF-OMN0011CN-C

1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4

How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6. 4-16-1 2 Series VS3115/3110 How to Order VS311 D L 5 01 5 Thread type Accessory (Option) Nil Rc Mounting With indicator light L P With manual override N NPT T NPTF E Nil Without bracket Port size Piping Electrical entry B With bracket G 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate Rc 01 02 02 03 00 Body ported

ISA11-4L-01BG ZSE2 ISE2 ISA15-1-01G ZSP ISl ZSM Accessories (Optional) PFl Bracket ISA-1-A Gauge G33-3-01 DIN rail ISA-2-1 to 7 IFl Gauge/G33-3-01 Bracket /ISA-1-A DIN rail/ISA-2-1 to 7 Material: SPC (Nickel plated) Material: Aluminum 10 hex. 100 110 q w e r t L 90 10 25 5 4-4.5 7.5 30 R1/8 34 42 28 4.5 35 27 9 16.5 13 5.6 L Applicable model Part No. 105 140 175 210 245 280 315 Description

The required lifting force can then be determined by dividing the theoretical lifting force by the safety factor t.

VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,

1 station N R S T Note 5) Note 6) The maximum number of stations differs depending on the electrical entry.

(However, there are no levers between t and q. They can be disconnected by merely pulling them apart.) Fig. (1) Black White 1 station (11 stations) A side coil B side coil (b) Lever Black White 2 station (12 stations) A side coil D-sub connector Connector terminal no.

Thread type FLUID IN Nil T Rc NPTF G NPT Built-in solenoid valve type F N T, F, N are order made specifications.