Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 41.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 41.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 45.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 45.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 45.00000 lb
CHILLER, RACK MOUNT, REFRIGERATION TYPE. Rack Mount Refrigeration Chiller. 41.00000 lb. O72.
CHILLER, RACK MOUNT, REFRIGERATION TYPE. Rack Mount Refrigeration Chiller. 41.00000 lb. O72.
Model: 10S6 (Side Ported), SI Unit: WF (PROFINET, Compatible Wireless Base Unit), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: WF (PROFINET, Compatible Wireless Base Unit), SI Unit Common, End Plate: 5 (Negative Common, 7/8" Connector), I/O Unit Stations: None, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting)
The SYA uses the same manifolds as series SY (non plug-in style) for types 20, 41, 42 and 45. One-touch fittings are available on body ported types.
The SYA uses the same manifolds as series SY (non plug-in style) for types 20, 41, 42 and 45. One-touch fittings are available on body ported types.
The SYA uses the same manifolds as series SY (non plug-in style) for types 20, 41, 42 and 45. One-touch fittings are available on body ported types.
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: WF (PROFINET, Compatible Wireless Base Unit), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Please contact us for the latest version.sales@ocaire.com, VALVE, DBL SOL, PLUG-IN, VALVE, VQC2000 SOL VALVE 5-PORT, WF, VQC2000 BUILT IN FITTING >1/4, .24114 lb, ModelPort sizeMass (Bottom ported)Mass (Rear ported)Leakage02R1/4117 g89 g1 x 10?5 Pa?m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s
Model: 10S6 (Side Ported), SI Unit Specification: WF (PROFINET, Compatible Wireless Base Unit), SI Unit Output Polarity, End Plate: 4 (SI Unit Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Block: C (U Side, 2 to 10 Stations, Internal Pilot, Built-in Silencer), A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch)