SMC Corporation of America
Elite Part Number Search
Search Results "HRSE018-A-23"

N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

MY-SA 2 x G F 2 x H E C D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.

D-F9WV D-F8 Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 18.5 31 6.5 20.5 41 8.5 20.5 33 4.5 17 20.5 31 4.5 15 20.5 41 4.5 15 20.5 51 4.5 35 22.5 43 6.5 27 22.5 33 6.5 17 22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4

+ A = 100 y, z + A 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A = 100

Seal guide B Slide plate Spacer Hexagon socket head cap screw MYMK-16-A MYMK-16-A MYMK-25-A MYMK-25-A MYMK-25-A Side seal unit Nickel plated Seal List No. !

Suitable for slow operation of a rotary actuator. CC CC Integrate a converter and a valve unit in a compact configuration. Possible to select 4 types of valve units for applications. Possible to connect a converter and a valve unit independently. Wide range of series in terms of converter capacity and valve unit flow rate control capability.

(mm) At the minimum stroke of standard adjustment bolt At the minimum stroke of 25 mm adjustment bolt Basic stroke At maximum stroke adjustment Bore size (mm) Bore size (mm) 10 15 25 Adjustment bolt fixing bolts Tightening torque Adjustment width across flats 10 15 25 A 2 A 26 A = 0.8 A = 0.6 A 0 M3 1.0 to 1.3 Nm 4 A 2 A 26 M5 4.6 to 6.2 Nm 5 Adjuster holder A Adjuster holder Adjustment

When used without a guide for a light load. (Application Example 1) When space is very limited.

Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.

The rotation angle can be adjusted between 90 to 190. n o ti r a a n t o g Rotation starting point 10 10 e End of rotation 160 L L e R B B L g o n B t at a r 160 io 160 n 10 10 n io r at a n t o g Rotation starting point End of rotation A A R e A Lmax Lmax Size 20 30 40 Lmax 24 27 31.5 Size 10 15 20 30 40 Size 20 30 40 Rotation starting point 15 18 24 27 31.5 24 27 31.5 10 End of rotation

Cover Rod cover Unit holding tie-rod A (2 depth 1 mm hole is on the side of tie-rod for attaching unit A.)

At piping This is equivalent to a magnetic field of approximately 18cm in radius from a welding area using a welding current of almost 15,000 amperes. To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit Foreign matter should not enter. Entering of foreign matter will cause malfunction.

-N02-36 F O_F.. 5.07lbs. (2 3 Ks) T T '75 PSIG (5 Kgt/cm2) A H c D tr F u H J K M N o 6 6 8 160 6\ 5 4 6 138 6) 1 5 7 (40) 1 2 2 (31) 0 0 6 (1 5) o 1 2 (3) 0 9 4 23 9) 1 5 7 (40) 1 0 6 (271 1 4 2 (36) 1 2 6 t32\ 1 2 0 30 5) , 2 t (6) A B D E F G H J K M N 6 8 0 (172 9l 5 6 l (142 4l 1 5 7 (40) 1.20 (30 5) 0 0 6 (1 5) 1 0 9 27 7l 0 8 9 2251 1 5 7 r40) 1 4 2 (36) 1 2 6 (321 1 m (30 s) o24 r6t

-N02-36 F O_F.. 5.07lbs. (2 3 Ks) T T '75 PSIG (5 Kgt/cm2) A H c D tr F u H J K M N o 6 6 8 160 6\ 5 4 6 138 6) 1 5 7 (40) 1 2 2 (31) 0 0 6 (1 5) o 1 2 (3) 0 9 4 23 9) 1 5 7 (40) 1 0 6 (271 1 4 2 (36) 1 2 6 t32\ 1 2 0 30 5) , 2 t (6) A B D E F G H J K M N 6 8 0 (172 9l 5 6 l (142 4l 1 5 7 (40) 1.20 (30 5) 0 0 6 (1 5) 1 0 9 27 7l 0 8 9 2251 1 5 7 r40) 1 4 2 (36) 1 2 6 (321 1 m (30 s) o24 r6t

25.5 25.5 A 32.5 33 37 28 32.5 32.5 A 31.5 22.5 27 27 A 35.5 26.5 31 31 MKl20 MKl25 MKl32 MKl40 MKl50 MKl63 Auto Switch Mounting Bracket Part No.

B ZY 2.5 A ZQ B With a stroke of 10 mm Dimensions: 10 mm Stroke (mm) ZF Model A B C D F Y H I J K K Q: 4 Q: 6 ZP ZPT10F10-0-A10 10 12 10 12.5 27 38.5 74.5 88.5 89.5 1.5 ZPT13F10-0-A10 39 23 Hexagon width across flats 13 13 15 Rc 1/8 ZCU 10.5 13 27.5 75 89 90 2 ZPT16F10-0-A10 16 18 M14 x 1 Additional Dimensions by Stroke (mm) AMJ 6.2 Hexagon width across flats 19 Misc.

port) (Piping port) 21.5 R1 P 8.5 6 6 R2 15 1.8 (Bleed port) With filter (80 Mesh) 217 17 21 45.5 24 32 3 position closed center/exhaust center/pressure center: SYJA5 20-M5 3 position closed center/exhaust center/pressure center: SYJA5 40-01 3 4 5 3 4 5 28 2-M5 X 0.8 4.3 22-M5 X 0.8 37.5 23 (Pilot port) (Mounting holes) (Pilot port) (Mounting holes pitch) A B 1 A B 11 5 3 1 24 A B 1 1 R

(1/8) 12(PA) port 12.6 13.5 83 23 VZA 91 VTA VGA 74.5 73.5 VPA VPA 28.5 X VPA3 M5 x 0.8 (Breathing hole) 13.5 28.5 57 1/4, 3/8 1(P) port For vacuum/VPA544V-102 03 A B 1/4, 3/8 2(A) port 13.5 28.5 51 2 x 5.2 (For mounting) 47 23 1/4, 3/8 3(R) port 17.6 NO 2A 42 52 NC 12 3R 1P NC 1/8 12(PA) port 13.5 12.6 91 23 74.5 73.5 28.5 X M5 x 0.8 (Breathing hole) 13.5 28.5 57 1/4, 3/8 1(P) port 1567

When a 6 (I.D.) steel pipe is used for piping, the flow velocity in the piping will be approximately 2.7m/s. 23