40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C ML1C LC-01 B 113.2 137.2 162.2 25 32 40 Mounting position Series ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 4.7-11
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 M5 U10/32 01 02 03 04 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
auto switches D-M9lV D-A9lV D-M9lWV D-M9lAV D-A9l D-M9lW D-M9lA D-M9l D-P3DWA Note 1) REB With 1 pc. 5 5 10 10 (5) 15 (10) 15 (5) 15 With 2 pcs. 5 10 10 10 15 (10) 15 (5) 15 REC Note 1) 25 is only applicable for the D-P3DWAl.
13 16 16 20 20 11 11 10.5 11.5 12.5 14 12 16.5 26 30 36 42 48 54 64 78 8 10 12 16 20 20 25 25 6 8 10 12 16 16 20 20 M4 x 0.7 90 94 109 109.5 135.5 142 155 160 13 15 18 21 24 27 32 39 M4 M4 M5 M5 M6 M6 M8 M10 7 7 9 9 9 9 10 10 5 5 6 6 10 10 12 12 42 46 53 53.5 59.5 66 72 77 19 19 30 30 38 38 60 60 8 8 10 10 12 12 16 16 51 58 68 82 100 108 139 153 8 8 10 10 12 12 16 16 58 64 83 93 112 120
[mm] *1 D1 Weight [g] With a rib X (X) Y Nylon Urethane Applicable tubing M L1 Oval type Round type 4 1/8 KQ2L04-01GS1 10 8.2 7.7 10 10 14.8 16.2 17.2 13.3 4.6 3.3 3 4.8 1/4 KQ2L04-02GS1 14 8.2 7.7 10 10 14.8 21.7 21.1 13.3 4.6 3.3 3 14.3 Rib 4, 6 8 to 16 6 1/8 KQ2L06-01GS1 10 10.4 9.7 12 10 15.5 17.3 19.4 13.3 11.4 9 4.5 5.2 1/4 KQ2L06-02GS1 14 10.4 9.7 12 10 15.5 22.8 23.3 13.3 11.4
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range. (AXB: Cannot select -10..10 V/-5..5 V/ -20..20 mA) -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data
Dimensions Applicable fittings fitting d Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" 4 4 148 L dimension 0 98 1 110.5 2 123 3 135.5 No. 5 160.5 6 173 7 185.5 8 198 9 210.5 10 223 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 L dimension 11 No. 235.5 12 248 13 260.5 14 273 15 285.5 16 298 17 310.5 18
0 10 20 30 40 50 60 50 60 40 30 20 10 0 10 20 30 Atmospheric pressure dew point ( C) 14-19-10 7 Membrane Air Dryer Series IDG Calculation of inlet air flow rate Q1, and confirmation of compressed air supply capacity.
to 24 VDC 10%, Ripple (P-P) 10% or less 15 mA or less 2% F.S.
Outlet air atmospheric pressure dew point C P1 = 0.5MPa P1 = 0.5MPa 10 10 20 20 P1 = 0.7MPa P1 = 0.7MPa 30 30 40 40 0 40 80 120 160 20 40 60 80 0 Outlet air flow rate l/min (ANR) Outlet air flow rate l/min (ANR) IDG20 IDG30 P1 = 0.3MPa P1 = 0.3MPa 0 0 Outlet air atmospheric pressure dew point C Outlet air atmospheric pressure dew point C P1 = 0.5MPa 10 P1 = 0.5MPa 10 P1 = 0.7MPa 20 20 P1
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
C HRZ008-L1-F 16 14 [HRZ008-L1-F] Cooling capacitykW 12 10 8 6 4 2 0 -20 -10 0 10 20 30 40 Circulating fluid setting temp.deg.
Port size Symbol 01 02 02 03 03 04 Body class Port size 1/8 1/4 1/4 3/8 3/8 1/2 Pilot port thread type 2 Symbol Nil N Thread type Rc NPT 3 4 Integral fitting type/Variations Model LVH20 LVH30 LVH40 Orifice diameter 4 8 10 Tubing O.D. Metric 3, 4, 6 6, 8, 10 10, 12 Inch Valve type 1/8, 3/16, 1/4 1/4, 3/8 3/8, 1/2 Symbol Type Basic type N.C.
10 11 12 13 12 13 19 Symbol 00 06 07 08 10 11 10 11 12 13 12 13 19 Body class Body class Tubing size Plug Tubing size Plug LVC 6 1/4" 6 1/4" LVA Base type 2 2 8 8 A Stacking type LVH 10 3/8" 10 3/8" Manifold stations 10 3/8" 10 3/8" LVD 02 2 stations 3 3 12 1/2" 12 1/2" LVQ 05 5 stations 12 1/2" 12 1/2" LQ 4 4 19, 3/4" 19, 3/4" LVN TI/ TIL How to Order Valve PA LVH 2 0 S07 A PAX Body class
TB C-12 type for pivot TT TR Td TE TF TH C-14 type for pivot (29.3) (33.1) (40.4) (49.2) (60.4) (74.6) 28-01 3.2 3.2 4.5 4.5 6 8 11 12 13 15 17 21 24 26 36 50 36 43 50 58 70 82 73 90 8 10 12 14 16 18 18 22 10 10 10 10 20 20 5.5 5.5 6.6 6.6 9 11 11 13.5 25 30 35 40 50 60 55 65 CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 20 25 32 40 50 63 80 100
Body size KK3P-50N KKH3S-50N 5/8 5/8 -60N -60N 6/9 6/9 1/8 1/8 -65N -65N 6.5/10 6.5/10 KK4P-50N KKH4S-50N 5/8 5/8 -60N -60N 6/9 6/9 -65N -65N 6.5/10 6.5/10 1/4 1/4 -80N -80N 8/12 8/12 -85N -85N 8.5/12.5 8.5/12.5 Series KKH are only available as sockets.
-2No.PS-OMS0004CN-D / 1 1.5 *3) *3)1 1 [] -3No.PS-OMS0004CN-D () () () () -4No.PS-OMS0004CN-D () * C3604+AI203(96)FKM () ZS-31-X175 X188 () NG NG -5No.PS-OMS0004CN-D * (Nm) R1/8 35 R1/4 812 (50N ) () * () 6 33 ( ) () 10 m DC(-)() FG -6No.PS-OMS0004CN-D * ( ) () CE -1060 * 2030 10 1% * -7No.PS-OMS0004CN-D 0 01 PSE57 / M12(3m) 0 (01MPa) L M12(3m) 3 (-100100kPa) N 4