Voltage symbol 24 VDC V100-61-3-05 DC 24 VZ 12 VDC V100-61-3-06 DC 12 VZ 100 VAC V100-61-2-01 100/110 VZ 200 VAC V100-61-2-02 200/220 VZ 110 VAC V100-61-2-01 100/110 VZ 220 VAC V100-61-2-02 200/220 VZ 240 VAC V100-61-2-07 240 VZ If an AC specification without DIN Terminal (DO) is selected, always use a DIN connector with surge voltage suppressor as the connector.

E 16 outputs D-sub connector (25 pins) Note1) 2) F 16 outputs Spring type terminal block (32 pins) Note1) 2) DM EX600 P F Digital Input/Output Unit Input/Output type Number of Inputs/Outputs and Connector Symbol Number of inputs Number of outputs Connector Symbol Description P PNP N NPN E 8 inputs 8 outputs D-sub connector (25 pins) Note1) 2) F 8 inputs 8 outputs Spring type terminal block

Water Hammer Characteristics VNC1 (N.C. 0.49 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.49 MPa VNC4 (N.C. 0.97 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.97 MPa 2.5 15A Peak pressure at valve closed (MPa) Peak pressure at valve closed (MPa) 8A 25A 2 1 20A 32 A F 15A 20A 40 A F 32 A F 1.6 0.8 25A 40 A F 50 A F 65F 50 A F 1.2 0.6 80F 65F 80F 0.8 0.4 0.4 0.2 0 1

Refer to p.0-39 to 0-46 for Safety Instructions and common precautions, and refer to p.3.4-2 for precautions on series CB. 75 20 80 90 2 Same side 100 100 100 100 D-A3C D-G39C D-K39C 20+35(n2) n=2, 3, 4, 80+35(n2) n=2, 4, 6, 8, 75+35(n2) n=2, 4, 6, 8, 90+35(n2) n=2, 4, 6, 8, Dif. sides n 100+100(n2) Same side 100+100(n2), n=2, 4, 6, 8, n=2, 3, 4, 5, 90 10 80 75 1 Replacement Dif. sides

Refer to p.0-39 to 0-46 for Safety Instructions and common precautions, and refer to p.3.8-2 for precautions on series CB. 75 20 80 90 2 Same side 100 100 100 100 D-A3C D-G39C D-K39C 20+35(n2) n=2, 3, 4, 80+35(n2) n=2, 4, 6, 8, 75+35(n2) n=2, 4, 6, 8, 90+35(n2) n=2, 4, 6, 8, Dif. sides n 100+100(n2) Same side 100+100(n2), n=2, 4, 6, 8, n=2, 3, 4, 5, 10 80 75 90 1 Replacement Dif. sides

[F 0] Units selection function Page 27 Symbol Model Default setting ISE40A MPa Nil or M ZSE40A(F) kPa ISE40A P psi ZSE40A(F) [F 1] Setting of OUT1 Page 28 Item Description Default setting Output mode Select hysteresis mode window comparator mode or OFF mode. Hysteresis mode Reversed output Select reversed output.

6 to 12 Applications B B 8 x 18 8 x 18 F F S S Conduit terminal: T (V) (U) E 25 32 G1/2 R T B 8 x 18 F S (mm) Electrical entry Grommet Model Applicable flange Conduit DIN terminal Conduit terminal U 103.5 106 106 B C D A E F H N Q R S N.C.

size (mm) Stroke range (mm) EA A EB EC F HA HB IA IB J KA KB L M B B A 10 to 50 56 36 +0.2 0 63 66 46 77 74 59.6 10.5 M6 x 1 6 103 100 7 50 0.2 35.4 8 60 75, 100 66 46 10 to 50 67.5 43.5 +0.2 0 80 77.5 53.5 98 95 79.5 12.5 M8 x 1.25 8 132 129 6 65 0.2 46 10 77 75, 100 77.5 53.5 10 to 50 79 53 +0.2 0 100 89 63 117 114 99 13 M10 x 1.5 10 156 153 6.5 80 0.2 56.6 10 94 75, 100 89 63 P Bore

to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.

Remote Type Water resistant construction conforming to IP65 Series PF2A Series PF2A For Air Flow rate measurement range (l /min) For Air For Water For High Temperature Fluid (Water 90C) 0.5 to 4 2 to 16 5 to 40 0.5 to 4 2 to 16 5 to 40 10 to 100 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 600 to 12000 Integrated Type Series PF2W Series PF2W For Water Application

A sensor with the specification Pt 100 has a resistance of 100 at 0C.

RLQB40-100 RLQB50-30 RLQB50-40 RLQB50-50 RLQB50-75 RLQB50-100 RLQB63-30 RLQB63-40 RLQB63-50 RLQB63-75 RLQB63-100 90 95 100 110 120 145 170 100 105 110 120 130 155 180 120 130 140 165 190 125 135 145 170 195 Mounting bolt 8 C Spring washer D Note) When mounting 50 to 63 cylinders from the rod side, be sure to use the attached flat washers because the bearing surface is limited. 9 13.5 12.5

Possible to use in vacuum to 100 kPa Tubing material Tubing O.D.

flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 N 9.5 11 11 18 18.5 20

Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.

28.5 30 188.5 (202.5) 197.5 (211.5) +l CJP 60 (74) 65 150 121 120 192 (206) 201 (215) +l Note) ( ): Long stroke CJ2 Flange (mm) CM2 Stroke range Rear flange ZZ Bore (mm) FT FD FX F E B C85 Without rod boot With rod boot Front Rear 20 25 32 40 50 63 80 100 112 118 120 132+l 140+l 142+l 6 7 7 8 9 9 11 14 5.5 5.5 6.6 6.6 9 11 11 14 28 32 38 46 58 70 82 100 2 2 2 2 2 2 3 3 12 14 18 25 30 32

fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!

fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!

(NA) (NA) Q + Stroke (mm) d Bore size (mm) Standard stroke (mm) A PA P Note) (N) (NA) PB PW Q E G GP H HG HN HP HT L F Slide Ball bushing 32 25, 50, 75, 100 10.5 28 20 45 27 9.5 110 66 26.5 67.6 64 33.5 100 14 53 1/8 70 120 160 121 40 25, 50, 75, 100 11.5 36 25 52 31 10.5 130 78 30.5 77.6 74 40.5 136 12 51 1/8 90 140 190 159 CX2 PA dimension is the center sorted factor of the L dimension