SMC Corporation of America
Elite Part Number Search
Search Results "CDLG1BA20TN-50-P-M9PSAPC-C"

C type snap ring for hole Bracket 16 Series MGG Dimensions Basic type/MGGB 20 to 50 4-F through, counter bore G Bottom 4-H Bracket (See table below.)

11 Specifications p. 12 Set Pressure Range and Rated Pressure Range p. 13 Functions p. 13 Internal Circuits and Wiring Examples p. 14 Dimensions p. 15 How to Order p. 19 Specifications p. 20 Set Pressure Range and Rated Pressure Range p. 21 Functions p. 21 Internal Circuits and Wiring Examples p. 22 Dimensions p. 23 Function Details p. 29 Made to Order Specifications p. 33 Safety Instructions

Switch Stop switch, Enable switch (Option) Cable length [m] 3 Enclosure IP64 (Except connector) Operating temperature range [C] 5 to 50 Option Enable switch is provided.

Speed exhaust controller Option None P The effective area is two times larger With spatter cover C Body size than that of speed controller. Hexagonal lock nut K M3 M5 1/8 1/4 3/8 1 2 3 4 5 Note) Option should be indicated in order of C and K. Only available for ASV310F,410F and 510F.

Bore size (Stroke (mm)) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.

SMC 50 35 5 SMC 6 28 (R) P P K U K C S U O C H L S O H L 38 AV AU Panel cut Panel thickness: Max. 4 Panel cut Panel thickness: Max. 3 34 AF 40 15.4 x 5.4 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR 8 x 6.5 79 13 45.5 VEX Atmosphere 106 G SET SET Pad side

Fluid temperature 5 to 50 (C) Ambient temperature 5 to 50 Lubrication Not possible (Initial lubricant: White vaseline is used.)

Select "P-1". U UP P D DO OW WN N b. When the "UP" and "DOWN" buttons on the driver operation are pressed, the display will be shifted as shown below, Select "P-3" and press the "SET" button. Point table No.1 No.2 No.3 No.4 No.5 No.6 No.7 c. The "UP" and "DOWN" buttons on the driver operation are pressed to Select "Spd", thenpress the "SET" button.

(31) 30 (31) 30 (31) VPA3 14 (15.5) 14 (15.5) 1/4, 3/8, 1/2 [1 (P), 5 (EA), 3 (EB) port] 50 (54.5) 50 (54.5) 4.5 (0.5) 92 (100) 3 position closed center/exhaust center/pressure center 3 4 5 VFA5 44(-P) 02 03 04 1/4, 3/8, 1/2 [4 (A), 2 (B) port] 36 (39.5) 27 (31) 14 (15.5) 20.5 (24.5) 1/8 [Pilot port: Lateral (-P)] 2 x 5.3 (2 x 6.5) (For mounting) 82 (87) 5 (6.5) 51.5 (55.5) 2B 4A 42 (45)

Moreover, due to the fact that bumpers are installed at each end of the piston, overall length is increased by 6mm for 32 and 40, 8mm for 50 and 63, and by 10mm for 80 and 100. 32 40 50 63 80 100 90 90 102 102 124 124 164 200 200 141 145 164 Width across flats Stroke range Bore size (mm) Effective thread length C B A D Ee11 F G H MB J K MM N P S V W ZZ 32 40 50 63 80 100 19.5 27 32 32 37

Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E

Part no. l Applicable snap ring t m 16.2 20.2 36.2 1.5 1.55 1.55 0.9 1.15 1.15 Type C 8 for axis Type C 10 for axis Type C 10 for axis IY-G02 IY-G03 IY-G04 CD-G02 CD-G25 CD-G03 CD-G04 Type C 8 for axis Type C 10 for axis Type C 12 for axis Type C 14 for axis 38.6 42.6 54 65 1.5 1.55 1.55 2.05 0.9 1.15 1.15 1.15 9-2-34

A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000

Auto switch symbol (mm) (mm) S Bore size (mm) B Bore size (mm) h C A g N S 26.5 30 38 45 55 66 86 104 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 61 63 71 75 81 90 105 132 43 45 51 55 60 67 78 96 18 18 20 20 21 23 27 36 33 36 45 50 56 68 87 111 76 81 96 105 116 135 165 207 6 6 7 7 7 7 7 7 N g C B + Stroke h + Stroke A + Stroke Note) For all dimensions other than the above, please refer

+ COM (For COM specifications, specify them separately.) 1 3 5 6 VZ1120MOZ-M5 Applicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.

EA, EB) 4, 2 (A, B) 1, 5, 3 Cv b C [dm3/ (sbar)] Cv b C [dm3/ (sbar)] Cv b C [dm3/ (sbar)] Cv b C [dm3/ (sbar)] (P, EA, EB) 2position Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 2position 1.9 0.35 0.49

Plate mounting support bracket Body mounting side support Auto switches mountable (both sides) Types of Units and Parts Type of units and parts Type of units Type of parts Single units P.1 to P.9 Combination units P.11 to P.18 Set parts P.11 to P.14 Parts P.16 Spare parts P.4 & 5 Optional parts P.2 Catalog pages Parts for combination units.