Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for w/o Flow Adjustment
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Operation Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Operation Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: -
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for w/o Flow
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom Side), Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket
Bore Size: 15mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 50mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M
Bore Size: 15mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 50mm, Auto Switch: Y59A--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: S (1 pc.)
Bore Size: 15mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 50mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Bore Size: 15mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 50mm, Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: High speed / high frequency, End Locking: -, Cushion: Rubber cushion,
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure