Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9

Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9

E B ,rt1 0f $ [,r PEEAA P B EAPE +q--dz 3 position Closed centr/Exhaust centet/Presute cenler .1&t*080 PEEA A P B EBPE Main Parts No.

23 8 14 8 14 10 16 18 24 36 34 41 67 33 40 66 33 40 66 30 38 63 51 67 4 2.5 1.8 1.6 d 8 5 KQB2 Applicable tubing 4 3 2.3 2.6 H1 H2 KS KX 6 4 3.3 6 10 5.8 M A L KM 14 8 6 14 6.6 5.3 17 Connection thread 17 KF 17 25 10 7.5 6.8 30 M 22 27.1 17 7.6 17 25 H/DL L/LL 10 8 7.3 35 22 27.1 KC 17 26.6 12 9 8 45 22 28.7 17 8.5 KK 17 26.6 12 10 9 57 KK130 22 28.7 28 29.9 16 13 22 9.3 12 101 22 DM Reference

C H G F E D B A Port size Model J K 959 317 289 363 157 152 910 260 R 3/4 IDU11C/11D 571 580 30 70 1009 337 309 383 207 175 960 280 R 1 IDU15C : Power source 220 to 240VAC 7

Specifications Body ported type Fluid Air Operating pressure range PSI (MPa) Internal pilot 22~100 (0.15 to 0.7) Max. 122 Ambient and fluid temperature F 30 or less Response time ms 5 Max. operating frequency Hz Non-locking push type, Push-locking slotted type Manual override Individual pilot exhaust type, Common Exhaust(pilot and main valve)type Pilot exhaust Not required Lubrication Free

30 22 17 17 22 51 12 19 H12-03 17 31.1 39 H12-04 34.1 Reference dimensions after R(PT) thread installation.

US Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.

(B contact) 3 wire GXL-N12FTB Switch specifications (SUNX Corporation) GXL-N12FT(B) Part no.

CJ216 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.

Proper tightening torque Nm 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 Nominal size of threads 1/8 1/4 3/8 1/2 3/4 Load operating voltage Power supply voltage Switch's internal voltage drop > [When used for air] 6. Be certain to observe specifications for the measured flow rate and maximum operating pressure. Operation at a flow rate exceeding the prescribed range can cause damage.

Tightening torque Nm 28 to 30 36 to 38 48 to 50 48 to 50 Tightening torque Nm 7 to 9 12 to 14 22 to 24 28 to 30 Thread Rc 3/4 Rc 1 Rc 1 1/2 Rc 2 Thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 2. Apply wrench only to the metal part of the pipings when installing the flow switch onto the system piping. Do not apply wrench to anything other than the piping attachment as this may damage the switch. 3.

2 G Coil insulation Materials and insulation type Series Symbol Nil A G H L Body material Seal material NBR FKM NBR FKM FKM 1 2 3 10 20 30 Brass Class B Stainless steel Note) 3 N.C. for Manifold Valve type Note) For pure water: The armature is a corrosion resistant construction.

IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Recommended air flow Tubing size Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Unrestricted 360 piping tube mounting. The connector for the IN side is a universal joint type that enables a tube to be connected in any direction within 360.

With lock B 40 32 25 16 40 32 25 16 With programless controller (PNP) 1P With programless controller (PNP) 1P Stroke Actuator cable length 10mm 10mm 12mm 12mm 16mm 16mm 20mm 20mm A A 100mm 100 100mm 100 5mm 5mm 6mm 6mm 8mm 8mm 10mm 10mm B B Without cable Without cable 8m * 8m * Nil Nil 8 8 1.5m 1 1.5m 1 10m * 10m * A A 1000 1000mm 1000mm 1000 3m 3 3m 3 15m * 15m * B B *Refer to the table

No.1 OFF ON P2 No.2 OFF ON P3 No.3 OFF ON P4 No.4 OFF ON P5 P6 P7 P8 7 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 50 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 F : 2019 1 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +

NO m: Refer to "Operating Conditions (Allowable eccentric load)" on page 12. m < Wo NO mo Wo m Wo mo < Wo YES mo Wo YES m Wo Model selected Allowable rotational torque Non-rotating accuracy T T (Nm) Non-rotating accuracy Bore size (mm) Stroke (mm) Bore size (mm) 40 0.08 100 75 50 30 63 40 0.06 3 4 5 7 100 63 0.05 10 12 16 22 100 13 17 22 30 Note) The value given for the non-rotating

a b d e f g h i j VXS23 1/4, 3/8 21 57 28.5 87.5 35 10.5 22 40 35 10 M5 56 75 2.3 30 6.5 10.5 31 37 VXS24 1/2 28 70 37.5 94 35 14 22 48 35 14 M5 56 75 2.3 34 6.5 10.5 35 41 VXS25 3/4 33.5 71 38.5 105.5 40 17 24.5 62 33 15.2 M6 70.5 92 2.3 39 6.5 10.5 43 46 VXS26 1 42 95 49.5 111.5 40 20 24.5 66 37 17.2 M6 70.5 92 2.3 41 6.5 10.5 45 48 13.5 Electrical entry Grommet DIN terminal Conduit terminal

x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder