9 18 5 48 1/43/81/2 AC40-06-B 1/8 235.4 149.1 37.8 38.4 77.6 110 33.8 3 50 80.2 40 9 18 5 48 3/4 AC50-B 1/8 282.4 220.1 41.2 93.1 110 43.3 3.2 70 96.2 50 11 20 6 60 3/41 AC55-B 1/8 292.4 234.1 44.7 98.1 110 43.3 3.2 70 96.2 50 11 20 6 60 1 1 AC60-B 1/8 297.4 234.1 44.7 98.1 110 43.3 3.2 70 101.2 50 11 20 6 60 Optional specifications Semi-standard specifications With barb With Metal
1.5 5 5 100 to 120 200 to 230 200 to 240 200 to 230 200 to 240 200 to 240 200 to 240 200 to 240 200 to 240 A1 LECSA1-S A 10 A2 LECSA2-S * The length of the encoder, motor and lock B2 LECSB2T cables are the same.
flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 N 9.5 11 11 18 18.5 20
N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.
Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -99No.PF-OMY0005-A Characteristics data Pressure loss (reference value) PF3A801H (For 1000 L/min) PF3A5802H (For 2000 L/min) Temperature accuracy (reference value) Models A B PF3A801H 100 L/min 1000 L/min PF3A802H 200 L/min 2000 L/min -100No.PF-OMY0005-A Dimensions Symbol Models A B D E F PF3A801H 68.3 43 64.4
-1/8 (OUT port) 11 P = 22 11 1.5 4.5 6 32 6 54 ( 19.5) 11 9.5 11 9.5 4-M4 x 0.7 10 24 10 46 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes.
Description Material Note 1 Body A PBT 2 Body B Brass Electroless nickel plating 3 Knob POM 4 Needle PBT 5 Needle guide Brass Electroless nickel plating 6 U-seal HNBR 7 O-ring NBR 8 O-ring NBR 9 Cassette 10 Seal NBR 11 Seal NBR No.
D-A9V D-A73 D-A80 D-F7NT D-A79W D-P3DWA Bore size (mm) A B A B A B A B A B A B A B 12 16 20 32 40 50 11 13 7 9 11.5 12 17 11.5 12 17 9 9 13 13 9 9 9.5 10 15 17.5 18 23 15 7 11 19 7 15 12 12.5 17.5 18 18.5 23.5 15.5 9.5 16.5 10.5 15 21 11 17 12 12.5 17.5 22.5 23 28 20 9.5 21 10.5 15 25.5 11 21.5 5.5 6 11 30.5 31 36 28 3 29 4 8.5 33.5 4.5 29.5 Note) Adjust the auto switch after confirming
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
Vertical Horizontal l : Load eccentricity m Mounting orientation m L L Up to 100 Up to 300 Up to 500 Up to 100 Up to 300 Up to 500 Maximum speed (mm/s) 50 (4) 200 (6) 50 (7) 200 (9) 50 (10) 200 (12) (2) 100 (5) 100 (8) 100 (11) Load eccentricity (l mm) (1) (3) Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also
Series VXH 2 3 4 Class 2 Class 3 Class 4 Material and insulation type VXF Symbol Nil D H N Coil insulation type Seal material Body material Class B Class H Class B Class H Stainless steel Brass (C37) Valve type VX3 FKM N.C. 2 VXA 1 Thread type VCHm 1 Rc NPT G Nil N F VDW Voltage 1 2 3 4 5 6 7 8 J 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 240 VAC 48 VAC 230 VAC VQ Port size LVM Class B
500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1 5 10 20 50 1 5 10 20 50 8 Series PF2A Dimensions: Remote Type Display Unit for Air (4-channel Flow Monitor) PF2A200, 201 40.1 (7.5) 40 6 2.5 L L/min 36.8 OUT1 CH FLOW SMC SET Sensor connector (option) Front protective cover + Panel mounting 53 9.4 (2) 47 42.4 46.4 Panel mounting adapter
ZX B B A B A B ZR P1 A A ZM 10 9 4 5 ZMA ZQ 3 ZH ZU ZL ZY ZF 11 ZP Section A-A' (Ejector) 12 SP 2 7 ZCUK AMJ 8 AMV AEP HEP Related Equipment 6 1 Section B-B' (Solenoid valve) Component Parts Replacement Parts Description Material Note Description Part no. No. No.
B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3.
(ASME B40.1 Grade B or better) psig/bar 4) (No code) Accuracy Cleanliness No oil ASME B40.1 level IV No oil Brass Polycarbonate Brass Phosphor bronze B Case Window Socket Bourdon tube Material MPa MPA 1.14 (29) 2.28 (58) 2.1 (53.5) 2.12 (54) NPT 1/4 0.42 (10.5) inch (mm) 3) Part number of pressure gauge itself.
Specifications W A D With shock absorber (mm) 11-MXPJ6 11-MXP10 11-MXP12 11-MXP16 Model MXPJ6 MXP10 MXP6 MXP12 MXP16 Model Cylinder bore size (mm) 6 10 12 16 Surface C to surface A 0.02 Parallelism Surface D to surface B 0.02 M5 x 0.8 M3 x 0.5 Port size Surface C to surface A 0.004 Traveling parallelism Fluid Air Surface D to surface B 0.004 Action Double acting M dimension tolerance 0.05
A B B A B A B 18 (26) A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 6 9 3 8 10 6.5 4.5 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18 (26) 16 (24) 25 6 9 3 8 10 6.5 4.5 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 19 (27) 17 (25) 32 7 10 4 9 11 7.5 5.5 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30)
AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 Nozzle size 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 1.5 2 1.5 2 1.5 2