10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20
(mm) (1) L D Applicable tubing Nylon Urethane KGR04-08 KGR04-06 1.8 2.0 3.3 3 2.5 3 4.7 4 6 8 10 4 8 10 12 10 12 12 16 16 17.5 18 18.5 21 34.5 36.5 39.5 37 37 39.5 42 41 42 44.5 50.5 50.5 10.4 16 5.6 4 KGR04-10 12.8 KGR06-04 KGR06-08 KGR06-10 KGR06-12 KGR08-10 KGR08-12 KGR10-12 KGR10-16 KGR12-16 4 4 12.8 17 6 18.5 Applicable fitting size d 13.1 10.4 15.2 20 4.0 4.6 33 8 15.2 20 18.5 26.1
(mm) 2, 4, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50 10, 13, 16, 20, 25, 32, 40, 50 10, 16, 25, 40 D I M E N S I O N S PA D D I A M E T E R S 2, 4, 6, 8 Material (colour) NBR (Black) Hardness 50 shore S P R I N G F O R C E ( N) Pad dia.
-A-20/40HRSH150-W-20/4025 25 Facility water temperature 32C Ambient temperature 32C 20 20 Cooling capacity [kW] Cooling capacity [kW] 15.7 15.7 15 15 Ambient temperature 43C 10 10 Facility water temperature 40C Ambient temperature 45C 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH200-A-20/40HRSH200-W-20/4030 30 Ambient
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
20 20 20 ORIG ACC/DEC 1000 1000 1000 1000 Creep speed 10 10 10 10 ORIG sensor 0 0 0 0 ORIG SW Dir 0 0 0 0 Undefined parameter21 0 0 0 0 87 - Appendix 1.2 LEF series setting value LEFS Step data default Model LEFS16 LEFS25 LEFS32 LEFS40 Lead [mm] 10 5 20 12 6 24 16 8 30 20 10 No. 0 0 0 0 Movement MOD ABS ABS ABS ABS to 500 500 250 1000 500 250 1200 500 250 500 500 250 Speed Strok 501-600
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
35oC 20 15 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Fig. 9-18 Cooling Capacity (HRL200-W-40 CH1) HRL Series 9.4 Cooling Capacity 9-17 HRX-OM-X037 Chapter 9 Documents 9.4.13 HRL100/200-W-40 CH2 3.0 2.5 Cooling capacity [kW] Ambienttemperature 45oC or less 2.0 (Max. 1.5 kW) 1.5 Rated 1.0 kW 1.0 0.5 0.0 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Up to
10 stations 02 2 stations (2) Manifold base (5 stations) Available up to 20 solenoids.
MI-A0802-10 MI-A0802-20 MI-A1202-10 MI-A1202-20 MI-A1202-30 MI-A2002-10 MI-A2002-20 MI-A2002-30 MI-A2502-30 MI-A2502-50 MI-A3202-30 MI-A3202-50 MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203-30 MI-A2003-10 MI-A2003-20 MI-A2003-30 MI-A2503-30 MI-A2503-50 MI-A3203-30 MI-A3203-50 e (1 pc.) @0 MI-A0801-10 MI-A0801-20 MI-A1201-10 MI-A1201-20 MI-A1201-30 MI-A2001-10 MI-A2001-20 MI-A2001
H G I J K L A B C D E F M R +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 9 9 16 16 +0.027 0 +0.027 0 +0.027 0 +0.027 0 36 38 55 55 16 18 22 22 9 9 12 15 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 16 30 30 36 44 M4 10 10 13 13 10
HRLE090-A-20/40 HRLE090-A-20/40 [50 Hz] [60 Hz] 12 12 Ambient temperature 32C Ambient temperature 32C 10 10 Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C 6 6 Ambient temperature 40C 4 4 Ambient temperature 45C 2 2 Ambient temperature 45C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] * The cooling capacity is the sum of
s] Note 3) Note 6) Vertical Basic 10 to 150 20 to 300 Note 4) 10 to 150 20 to 300 Note 4) Compact 10 to 150 20 to 300 Note 4) Pushing speed [mm/s] Note 5) 10 20 10 20 Acceleration/Deceleration [mm/s2] 3000 Backlash [mm] 0.2 or less Positioning repeatability [mm] 0.05 Lost motion [mm] Note 7) 0.2 or less Impact/Vibration resistance [m/s2] Note 8) 50/20 Actuation type Slide screw Guide type
-A-20. 9-10 9.4.2 HRSH090-A-40. 9-10 9.4.3 HRSH090-W-20-HRSH090-W-40. 9-11 Pump capacity . 9-12 9.4.4 HRSH090-A-20/40-HRSH090-W-20/40. 9-12 9.5 Types of hazard labels . 9-13 9.5.1 Locations of Hazard Labels . 9-14 9.6 Compliance standard . 9-15 9.7 Sample DoC. . 9-16 9.8 Daily Check Sheet . 9-17 Chapter 10 Product Warranty . 10-1 HRSH Series HRX-OM-R026 Contents HRSH Series HRX-OM-R026 Chapter
Cushion NCA D-X Mounting 20Standard Stroke Data Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 Smooth movements even at 0.4 to 2 inch/sec Auto switch mounting available.
1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 Example: NCDA1B150-0200R+0300-XC11 will stroke 2" then an additional 3" for a total stroke of 5".