If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 8 Filter Rc1 20m Refer to the table below * Recommended filters for facility water inlet Applicable model Recommended filter HRSH100/150 FQ1012N-10-T020-B-X61 Note HRSH200/250 FGESA-10-T020A-G2 Note Note) The filter shown above cannot be directly connected to the thermo-chiller.

View B-B 50 HRZ HRZD Accessory: Y-strainer mounting view HRW * Mount it by yourself on the circulating fluid return port.

Switch assy O ring Gasket Base 3.8-4 ISA Dimensions/Centralized Wiring (Terminal Block Box Style) Unit Manifold With bracket Deflection level indicator Terminal block box 34 L2 40 34 L1 Deflection level indicator Terminal block box 75 40 90 10 10 10 Rc1/8 SUP.

B A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required. Display Select NPN or PNP A NPN PNP Voltage input 1 V 5 V Current input 4 mA 20 mA Analog output of 0 to 10 V is also available.

C Y Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581

22.5 15.5 9.6 17.5 10 2.5 25.5 24.5 13.7 15.4 14.29 7 18 2.7 8 9 18 5 10 19 3.2 10 20 32 12 20 28 16 23 33 59 28 36 62 10-32UNF 12.7 2.3 9.3 15.6 1 16 22 11.11 5 32 23 16 1 8 1 4 10.4 10 18 3 26 25 14.29 KQ2L05-32 10-32UNF 20 22 2.3 11.11 11.4 10 19.5 3 16 1 8 1 4 22.5 26.5 15.1 23.5 27.5 29.5 24.5 28.5 30.5 26.5 29.5 31.5 35.5 31.5 33.5 37.5 24 26 16.5 3.5 14.29 10-32UNF 2.3 18.1 13.6

9 16.5 19 15 23 6 Width across flats 10 39 19 (4 locations) K (58) 25 19 8 Closed E 9 9 25 Open F 13 13 43 G 4 x M5 x 0.8 through (Thread for mounting attachment) Model A B C D E F G H J MHL2-16DZ 40 45 60 28 68 98 128 26 98 MHL2-16D1Z 70 75 90 58 110 170 200 50 152 MHL2-16D2Z 90 95 110 78 130 210 240 70 192 J dimension is at fully closed.

Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01-06-X214 Operation 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Caution

Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.

Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.

ZPG13C-7A-X2 7 7 7 7 ZP13C ZP 16 C ZPG16C-7A-X2 7 7 7 8 ZP16C ZP 20 C ZPG20C-7A-X2 9 10 10 11 ZP20C ZPT3-7A-X2 ZP 25 C ZPG25C-7A-X2 10 10 10 11 ZP25C ZP 32 C ZPG32C-7A-X2 10 11 11 12 ZP32C ZP 10 B ZPG10B-7A-X2 7 7 7 8 ZP10B ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12

Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V

Model A side B side JIS Symbol A relay output module of devices up to 110 A B is available for control VAC, 3 A. 4(A) 2(B) A B N.C. valve N.C. valve 3(EB) SOL.b SOL.a 1 2 SV A00 5(EA) B side passage symbol: Green B side manual override: Green Tie-rod base manifold (For SV1000/2000/3000/4000) 1(P) 4(A) 2(B) A side coil A side spool valve B side spool valve N.O. valve N.O. valve 1 2 SV B00

White Black Black Red Red Red Black Black White 1 station SOL. 2 stations 2 SOL. 3 3 stations SOL. 4 stations 4 SOL. 5 5 stations SOL. 6 stations 6 SOL. 7 7 stations SOL. 8 stations 8 (a) SOL. 9 9 stations (2) SOL. 10 stations 10 SOL. 11 11 stations (b) (1) Black White SOL. 12 stations 12 SOL. 13 13 stations SOL. 14 stations 14 SOL. 15 15 stations SOL. 16 stations 16 How to Calculate the

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation

+0 052 0 Depth 1.5 M5 X 0.8 (Finger closing port) M5 X 0.8 (Finger opening port) Auto switch mounting groove (4 locations) G 65 28.2 4-M6 X 1 H (Piston rod and rack screw) 6.5 1 11 15 10 24 14 Width across flats 10 20 46 24 (4 locations) A (70) 30 24 24 10 30 12.5 12.5 Closed E 54 Open F 17 17 4-M6 X 1 through (Thread for mounting attachment) A B C D E F G H 54 96 116 J 120 195 235 Model

E Stroke F E 20 7 900 20 7 850 18 6 800 18 6 750 16 5 700 16 5 650 14 4 600 14 4 550 22 8 950 22 8 1000 12 Triple Axis P&P Unit Dimensions (reference drawing for assembling) 39 L 130 4H10depth5 4-M6 x 1depth14 4-M8 x 1.25depth18 80 31 5 4H10depth5 92 B section detail (S=2/1) B (Stroke+145) 25 18 (52) Stroke+188 (92) 10 10 Stroke+240 60 2 60 31 62.5 Reference plane 130 63.5 3 40 (Refer to

size: 32A, 40A, 50A Applicable cable O.D. 6 to 8 (D, DL) Pg9 Pilot port 12 (P1), 10 (P2) Port size: refer to table below Manual override (Non-locking push type) G (Air operated) H (Grommet: G) I (DIN terminal: D, DZ) P1 P2 F E D A B B C A J Main port 1 (A) (Back side 2 (B)) Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H I J Model VNA5-32A VNA6