Width across flats KA 4 x J 4 x FD GB flats B1 MM E RY BF FY d D e C B V H1 AL N RT FT BN C B 10.2 f l A K M ZZ + l + Stroke h + l FZ FX S + Stroke H ZZ + Stroke (mm) Bore size (mm) Stroke range (mm) 40 50 63 80 100 A AL B B1 BF BN BP BQ C D E FD FT FV FX FY FZ GA GB GC GD GL GL1 GR H H1 Up to 800 30 27 60 22 71 96 1/8 1/8 44 16 32 9 12 60 80 42 100 85 15 50 16 12 12 10 51 8 Up to 1000 35
L d l m t Applicable bore (mm) Applicable snap ring Dd9 Type C 8 for axis 0.9 1.15 1.15 1.15 1.15 1.35 1.5 1.55 1.55 2.05 2.05 2.45 38.6 42.6 54 65 79.6 97.8 7.6 9.6 11.5 13.4 15.2 17 43.4 48 59.4 71.4 86 105.4 CD-G02 CD-G25 CD-G03 CD-G04 CD-G05 CD-G06 20 25 32 40 50 63 8 10 12 14 16 18 0.040 0.076 Material: Rolled steel mm Type C 10 for axis 0.040 0.076 R1 U1 Applicable bore (mm) Part no
RLQ MLU ML1C DBore size (mm) Stroke range (mm) 40 50 63 80 100 A AL B B1 BN BP BQ C CD CX D E F GA GB GC GD GL GL1 GR H1 -X 0.1 0.3 15 30 27 60 22 96 1/8 1/8 44 10 16 32 10 85 15 52 16 12 12 10 8 Up to 500 0.1 0.3 18 35 32 70 27 108 1/4 1/8 52 12 20 40 10 95 17 56.5 20 13 15 12 11 Up to 600 200.1 0.3 25 35 32 86 27 115 1/4 1/4 64 16 20 40 10 102 17 67 20 18 12 15 11 Up to 600 0.1 0.3 40
B + Stroke L K A + Stroke 2 x 4-M6 x 1.0 effective depth 10 M W Rod end male threads H1 Rod end nut C1 X L1 Rod end male threads mm Bore size (mm) C1 X H1 L1 20 25 18.5 12 14 M8 x 1.25 22.5 15 17.5 M10 x 1.25 Standard type mm A B C D E E1 E2 F H K L M Q W Bore size (mm) 20 25 Stroke range (mm) 15 to 50 36.5 32 7 10 36 18 21 15.5 M5 x 0.8 8 4.5 25.5 21 39 15 to 50 41.5 36.5 12 12 40 20 23.5
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50
Example) D-A90L Contact protection box OUT () Brown [Red] Reed switch CD-P11 OUT () Blue [Black] CD-P12 Auto Switch Weights D-A93(V) (g) D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Type Brown [Red] Contact protection box OUT (+) Brown [Red] Resistor Lead wire length 0.5m 7 7 6 7 8 8 Reed switch Zener diode Lead wire length 3m 35 35 30 35 41 41 CD-P11 OUT () Blue [Black] CD-P12 Blue [Black]
Specifications CD-P12 CD-P11 100VAC Part no. 200VAC 24VDC Load voltage 25mA 12.5mA 50mA Maximum load current (Example) D-F9PL61 Lead wire length Switch connection side: 0.5m Load connection side: 0.5m Flexible wire specification Internal circuits CD-P11 OUT Brown [Red] Surge absorber Choke coil OUT Blue [Black] CD-P12 OUT(+) Brown [Red] Choke coil Zener diodes OUT() Blue [Black] Dimensions
CB CD CE CH CW F L A KK ER NY-150 NY-325 0.765 1.265 0.5 0.75 1 1/2 2 3/8 1 1 3/8 1/2 5/8 1 1 1/4 3/4 1 1/4 3/4 1 1/8 7/16-20 3/4-16 1/2 3/4 CD dia. KK Tap through Order to Match Rod Thread Rod Eye Pivot Pin Pivot Pin Part no. CD 1 CD 2 CL CP Part no. A CA CB CD ER KK Part no.
Load voltage Max. load current CD-P11 CD-P12 Note) Hysteresis may fluctuate due to the operating environment.
Auto Switch Hysteresis Contact Protection Box: CD-P11, CD-P12
Applicable bore size (mm) Dd9 L1 d L2 m t Included retaining ring CD-G02 20 8 0.040 0.076 43.4 7.6 38.6 1.5 0.9 Type C8 for axis CD-G25 25 10 0.040 0.076 48 9.6 42.6 1.55 1.15 Type C10 for axis CD-G03 32 12 0.050 0.093 59.4 11.5 54 1.55 1.15 Type C12 for axis CD-G04 40 14 0.050 0.093 71.4 13.4 65 2.05 1.15 Type C14 for axis CD-G05 50 16 0.050 0.093 86 15.2 79.6 2.05 1.15 Type C16 for axis
IY-G02 IY-G03 IY-G04 Type C 8 for axis Type C 10 for axis Type C 10 for axis NT-02 NT-03 NT-G04 CD-G02 CD-G25 CD-G03 CD-G04 0.040 0.076 8 Type C 8 for axis Type C 10 for axis Type C 12 for axis Type C 14 for axis 0.9 1.5 20 25, 32 40 21 7.6 9.6 9.6 16.2 13 17 19 20 25, 32 40 (15) 12.5 16.5 18 M8 x 1.25 5 6 8 0.040 0.076 8 0.9 1.5 38.6 7.6 20 25 32 40 43.4 0.040 0.076 10 0.040 0.076 10 1.15
D H1 KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS [mm] Connection thread L1 A Width across flats Nozzle size Part no.
-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R 1/4 R 1/4 R 1/4 14 14 14 52 52 52 46 46 46 T D H1 A L1 VMG Low noise nozzle with male thread: KNS (mm) Model Nozzle size D Connection thread L1 A Width across flats H1 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 R 1/4 R 1/4 R 1/4 R 1/4
D-A90, A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch (g) Mass OUT () Blue D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Model D-A93, A93V 0.5 6 6 6 6 8 8 3 Lead wire length (m) LED Brown (Red) OUT (+) Brown 30 30 30 30 41 41 Contact protection box CD-P11 CD-P12 Resistor Dimensions (mm) Reed switch Zener diode D-A90/D-A93/D-A96 OUT () Blue 2 2.8 4.5 Blue (Black) 2.7 4 22 (24.5
Applicable bore size (mm) Applicable retaining ring Applicable retaining ring l l A1 L1 NDH10 MM R1 U1 Dd9 t Dd9 t NX d L m d L m CD-J010 0.030 0.060 0.030 0.060 + 0.048 0 10 10 10 CD-J010 I-J010SUS 8 21 9 3.1 8 1.2 0.3 1.2 0.3 3.3 3.3 3.3 3 3 Type C 3.2 Type C 3.2 M4 x 0.7 15.2 12.2 15.2 12.2 + 0.048 0 0.030 0.060 0.030 0.060 16 16 16 CD-Z015SUS I-J016SUS IY-J015SUS Retaining rings are
Applicable bore size (mm) B C D d H Dd9 L d Part no. 0.040 0.076 0.040 0.076 0.050 0.093 14 0.050 0.093 0.040 0.076 0.040 0.076 0.040 0.076 CD-G02 CD-G25 CD-G03 CD-G04 NT-02 NT-03 NT-G04 20 25 32 40 20 25, 32 40 21 25.6 41.6 7.6 9.6 9.6 IY-G02 IY-G03 IY-G04 M8 x 1.25 5 6 8 20 25, 32 40 13 17 19 15.0 19.6 21.9 12.5 16.5 18 8 10 12 8 10 10 43.4 48 59.4 71.4 7.6 9.6 11.5 13.4 M10 x 1.25 M14
Dimensions/12 to 25 Standard (Through-hole/Both ends tapped)/CQSYB, CDQSYB 12 2-M5 x 0.8 Auto switch Lead wire min. bending radius 10 H thread effective depth C 2 x 4-OB counter bore depth RB 2 x 4-OA effective depth RA Note 1) Q F 16 I 4-N through D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod end male thread Bore size (mm
Bore size (mm) Part no. m d (Drill through) Cotter pin Note) l d Dd9 L H B C D CNG 3 x 18l 4 x 25l 4 x 35l Note) A cotter pin should be used together with a plain washer. 6 8 11 13 16 4 4.5 5 3 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 0.040 0.076 0.050 0.093 0.065 0.117 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 32, 40 50, 63 80, 100 10 14 22 32 40 50
2 10-15-13 Series CVJ3 Single Acting, Spring Return/Basic Style (B) M5 x 0.8 CVJ3B S Bore size Stroke M5 x 0.8 28 [34.5] 48 [49] Manual override Width across flats B1 Rod End Nut Bore size (mm) 10 16 H1 B1 7 3.2 16 [17] S + Stroke Z + Stroke 8 4 [ ]: Denotes the values of AC. 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st Bore size (mm) NN NB NA MM HX H F D C B A ND Z Z S Z S Z S S 128