How to Order 30 03 B AFD D Symbol Description Body size 20 30 40 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 06 3/4 Nil Without mounting option a Mounting B With bracket Option Nil Without auto drain b Float type auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O.
JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) < Example of required specifications > JIS B 8433-1993: Manipulating industrial robots Safety. etc. *2) Labor Safety and Sanitation Law, etc.
Signal contents A DC output B DC output C DC output 1) Common to HED003-C2A, HED005-C2A, HED007-C2A RS-485 D DC output E DC output Pin No. Signal contents D C F DC output 1 RS-485 BUS + 5 4 3 DC connector (HED007-C2l) G FG 2 RS-485 BUS 2 1 3 Unused 4 Unused 3.
How to Order 30 03 B AFM D Symbol Description Body size 20 30 40 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 06 3/4 Nil Without mounting option a Mounting B With bracket Option Nil Without auto drain b Float type auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O.
Type 21P Single base/B mount Common SUP/Common EXH 3 to 12 stations Valve Rc 1 8 M5 x 0.8 Model Manifold type P(SUP), R(EXH) Valve stations A, B port location 1(P), 3(R) port 4(A), 2(B) port Port size Valve (1) effective area (mm2) (Cv factor) 1 4: 0.48, 4 3: 0.85 VZ1120 Socket: 26 pins MIL, with strain relief (Conforming to MIL-C-83503) Applicable flat ribbon cable connector Internal wiring
8 9.6 10 17.5 15.5 2.5 1 8 1 4 1 8 10.4 10 18 16 3 5 32 1 4 1 8 1 4 13.2 10 20.5 17 4.6 1 4 3 8 Applicable tubing 1 4 3 8 3 8 17.9 17 25.5 21 7 Connection thread 1 2 3 8 21.7 17 28 22 9.6 1 2 1 2 Reference dimensions after NPT thread installation.
Gasket DXT192-10-5 (Use caution to the orientation.) 3-3-30 5 Port Solenoid Valve Base Mounted Series VZ3000 Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Type of actuation Weight (g) 1 4/2 (P A /B) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) b C [dm3/(sbar)] Cv C [dm3/(sbar)] Cv b Grommet 125 (75) 170 (120) Single Double Closed center Exhaust center
For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 Paddle Style Flow Switch Series
N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40W-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50W-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D Contents Page 1.
B A B B 45 45 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 1.0 (25.4) 1.0 (25.4) AP3650 AP3657 1.88 (47.8) 0.44 (11.2) 3.02 (76.7) 0.13 (3.3) 0.4 (10.2) 1.87 (47.5) A B B 0.44 (11.2) 3.6 (91.4) 45 1.0 (25.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) A B B Connections A B inch inch (mm) (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV4 MV4 TW4 FV6 MV6 TW6
proportional valve (VEP type) Current 5 (R1) 4 (A) 1(P) 2 (B) 3 (R2) IRV Simplifying circuit design Space-saving and piping work eliminated 2 (A) 1 (P) Selection of inlet pressure or atmosphere 3 (R) 5 (R1) 4 (A) VEX1 1(P) 2 (B) 3 (R2) SRH SRP SRF System Diagram ARX20 Power amplifier VEA25 VCHR Control circuit Voltage Current ITV 0 to 5 VDC 4 (A) IC 2 (B) PVQ Electro-pneumatic proportional
Plate B (with O-ring) Tighten by hand and give it an additional turn approx. 1/4 rotations with a wrench.
Standard Specications Model AW20-B AW30-B AW40-B AW40-06-B AW60-B Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 Pressure gauge port size Note 1) 1/8 Fluid Air Ambient and fluid temperature Note 2) 23 to 140F (5 to 60C) (with no freezing) Proof pressure 218 psi (1.5 MPa) Maximum operating pressure 145 psi (1.0 MPa) Set pressure range 7.3 to 123 psi (0.05 to 0.85 MPa) Nominal filtration
(B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-27 Setting of contact output signal 1 to 3 No.
(October 1999) Vacuum ejector system Manifold ZZQ108A-B S C-A (1) (2)(3) (4) (3) Vacuum release pressure supply port (PD port) (1) Number of stations B None (Release pressure is 01 1 stations supplied from the P port.) 02 2 stations C Note 1) Provided (Breaking pressure: Supplied : from D port) 08 8 stations Note 1) If the standalone product does not have the energy saving function, select
ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4.
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.