Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm
L/A indicator Table 6-2 L/A indicator L/A Meaning Green ON Connection via Ethernet to the SI Unit via BUS IN/OUT But no transmission or reception of Ethernet telegrams on BUS IN/OUT Orange ON or Connection via Ethernet to the SI Unit via BUS IN/OUT Transmission or reception of Ethernet telegrams on BUS IN/OUT Flashing Green/Orange OFF No physical connection to the port Green Flashing Received
Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2
L 16 60 S 5 L CVJ3 Without auto switch L S 5 L J79W 16 60 CDVJ3 With auto switch Number of auto switches Action S T Single acting, Spring return Single acting, Spring extend Built-in magnet 2 pcs. 1 pc. n pcs.
Integrated display 7 Rated flow range (Flow rate range) Option 2 (Refer to page 907.) 0.2 to 10 (5) l/min 0.5 to 25 (12.5) l/min 1 to 50 (25) l/min 2 to 100 (50) l/min 10 25 50 11 Option 1 (Refer to page 907.) ( ): Fluid: CO2 Calibration certificate Flow adjustment valve None With calibration certificate Nil A Nil S None Yes The certificate is written in English and Japanese.
AME150 AME450 AME650 B 1 8B 1B 1 2 0.1 MPa 0.1 MPa 0.1 MPa Max. flow line Max. flow line Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800)
/min (ANR)) Air flow rate (l /min (ANR)) AMH550 AMH250 B B 3 4 1 4 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMH650 AMH350 B 1B 3 8 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) 0.5 Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow
Keep the fluid level between H and L of the level indicator.
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
MHT2-32D L = 100 mm Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) MHZ Pressure 0.6 MPa MHF 0.4 MPa 0.2 MPa L Gripping point distance (mm) MHL Opening/Closing angle (Both sides) MHR MHT2-40D L = 120 mm MHK MHS MHC Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F , which is the thrust of one
MHT2-32D L = 100 mm Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) MHZ Pressure 0.6 MPa MHF 0.4 MPa 0.2 MPa L Gripping point distance (mm) MHL Opening/Closing angle (Both sides) MHR MHT2-40D L = 120 mm MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
min (ANR) Flow rate L/min (ANR) SRP1101-01 Conditions/Inlet pressure: 0.5 MPa SRP1-01 Conditions/Inlet pressure: 0.7 MPa 0.25 0.50 0.20 0.40 Outlet pressure MPa Outlet pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative value) Fluid: Air Initial
sResponse timeHysteresisPower supply voltageResistancePF2W740Water3.5 to 45 l/min3.5 to 45 l/min5 to 40 l/min0.5 l/min0.5 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?