SMC Corporation of America
Elite Part Number Search
Search Results "NCDMC150-1200-XB9"

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

rating Static capacity Varistor voltage rating (range) Maximum limit Power supply voltage Rated pulse Permissible circuit voltage Surge current immunity Energy immunity voltage (reference Varistor V1mA value) power AC [Vrms] DC [V] 8/20 s [A] 2ms [J] [W] [A] [V] [pF] [V] 100V class TND20V-431K 275 350 10/1 time 195 710 1300 430(387 to 473) 200V class TND20V-471K 300 385 7000/2 time 215 775 1200

Static Varistor voltage Maximum limit capacity Power supply Rated rating (range) Permissible circuit Surge current Energy voltage (reference Varistor pulse V1mA voltage immunity immunity value) voltage power AC[Vrms] DC[V] 8/20 s[A] 2ms[J] [W] [A] [V] [pF] [V] 100V class TND20V-431K 275 350 10/1 time 195 1.0 100 710 1300 430(387 to 473) 200V class TND20V-471K 300 385 7000/2 time 215 775 1200

85 L 3 2 35 80 2.3 (4 ) 160 180 13 24 13 (e) (FR-BIF-(H)()) 10MHz [mm] FR-BIF 4mA 300 29 MC NFB 42 5 L 1 4 L 2 7 58 29 L 3 44 FR BI F 200V FR-BIF FR-BIF-H (f) () CHEMI-CON TND20V-431K TND20V-471KTND20V-102K () () V1mA AC[Vrms] DC[V] 8/20s[A] 2ms[J] [W] [A] [V] [pF] [V] TND20V-431K 275 350 10/1 195 1.0 100 710 1300 430(387473) 100V 200V 7000/2 TND20V-471K 300 385 215 775 1200

rating Static Varistor voltage Maximum limit capacity Power supply Rated rating (range) Permissible circuit Surge current Energy voltage (reference Varistor pulse V1mA voltage immunity immunity value) voltage power AC[Vrms] DC[V] 8/20 s[A] 2ms[J] [W] [A] [V] [pF] [V] 100V class TND20V-431K 275 350 10/1 time 195 710 1300 430(387 to 473) 200V class TND20V-471K 300 385 7000/2 time 215 775 1200

7 130 85 35 80 2.3 2 2 (4) 4 160 180 11 29 11 (e) (FR-BIF-(H)()) 10MHz 200VFR-BIF 400VFR-BIF-H [mm] FR-BIF-(H) () 4 mA 300 29 MC MCCB MCCB MC 42 L2 L1 4 5 29 7 L3 58 44 (f) () CHEMI-CON TND20V-431K TND20V-471KTND20V-102K () () V1mA AC[Vrms] DC[V] 8/20s[A] 2ms[J] [W] [A] [V] [pF] [V] TND20V-431K 275 350 10/1 195 710 1300 430(387473) 100V 200V 7000/2 TND20V-471K 300 385 215 775 1200

rating limit Static Varistor voltage rating voltage capacity Power supply (range) (reference Varistor Surge V1 mA Permissible circuit Energy Rated pulse value) voltage current voltage immunity power [A] [V] immunity AC [Vrms] DC [V] 8/20 s [A] 2 ms [J] [W] [pF] [V] TND20V-431K 275 350 10/1 times 195 710 1300 430 (387 to 473) 200 V 1.0 100 class TND20V-471K 300 385 7000/2 times 215 775 1200

(f) () CHEMI-CONTND20V-431KTND20V-471K () () V1mA [A] [V] AC[Vrms] DC[V] 8/20s[A] 2ms[J] [W] [pF] [V] 200V TND20V-431K 275 350 10/1 195 1.0 100 710 1300 430 (387473) TND20V-471K 300 385 7000/2 215 775 1200 470 (423517) [:mm] D H T E () L d W D T Max. Max. Max. 1.0 min. 0.05 1.0 TND20V-431K 21.5 24.5 6.4 3.3 20 0.8 10.0 TND20V-471K 6.6 3.5 H .

is connected ) Branch current for input ( Note ) Max. 0.5 [A] per branch ( when SI unit and input devices are connected ) Communication method Protocol: Dedicated for SMC Speed: 750kbps Number of branches for input/output 4 branches ( 16 points/branch ) for input 4 branches ( 16 points/branch ) for output Loop resistance 110 /km Capacity 30pF/m or less Impedance 135 165 Cable length [m] 1200

DC-DC Converter (Insulation) 19.2 kbps 45.45 kbps 93.75 kbps 187.5 kbps Communication speed Max. wiring length 9.6 kbps 1200 m 1000 m GND +24 V TD+ TD0 V Power supply for output INPUT OUTPUT 100 m Max. wiring length Communication speed 500 kbps 1500 kbps 3000 kbps 6000 kbps 12000 kbps 400 m 200 m +24 V 0 V COM D : Max. wiring length differs depending on the specification of a cable.

EX140-SMJ1 Applicable system CC-Link Ver.1.10 Occupied station 1 station Station number setting range 1 to 64 (Set with a rotary switch) Communication specification Station type Remote I/O Communication speed 156 k/625 k/2.5 M/5 M/10 Mbps Cable length between stations 20 cm or more Max. cable length 1200/900/400/160/100 m Communication supply voltage 15 to 30 VDC Solenoid supply voltage 24