SMC Corporation of America
Elite Part Number Search
Search Results "MXZ20L-5-M9PVSDPC3"

5 6/6 15/22 18/23 3/4 5/6 9/10 13/14 6/7 13/14 Rc 1/2 Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass 3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 20 14 30 23 30 20 25 60 46 Refer to page 94.

Nil L Z N (Example) A73C (Example) A73CL (Example) A73CZ (Example) A73CN 0.5 m 3 m 5 m None Since other auto switches are available other than those listed above, refer to page 350 for details on other applicable auto switches. Auto switch is shipped together (not assembled).

Option 1 W Nil DIN Rail Mounting Bracket (Order Separately) With lead wire with connector (2 m) Connector cover (Silicone rubber) ZS 33 R With lead wire with connector (2 m) ZS-33-F S Stations ZS-33-D ZS-33-D S 1 2 3 4 5 1 station 2 stations 3 stations 4 stations 5 stations IN IN N Note) If an accessory is required, order separately using ZS part numbers.

voltage suppressor Red 5 6 V S R Diode Note) Analog output is available only on grommet type.

Series 10-VQD1000 [Option] 4 Port Direct Operated Poppet Solenoid Valve How to Order Valve Clean series Valve option Nil Standard (2 W) V Vacuum (2 W) U For large flow (3.2 W) W For large flow, Vacuum (3.2 W) Energy saving type Rated voltage 5 24 VDC 6 12 VDC Body type 2 Body ported (Single unit) 3 Body ported (Manifold) 5 Base mounted 10 V Q D 1 1 5 1 U 5 L M5 Electrical entry CE-compliant

AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 20 10 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 10 5 20 10 0 5 20 10 10 0 5 0 10 Number of needle rotations Number of needle rotations Number

Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 6 10 16 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 5, 10, 15, 20, 25, 30

(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Light turns ON when pressure drops below the set minimum.

(at 25C water) Temperature characteristics 5% F.S. (0 to 50C, based on 25C) Pulse output, N channel, open drain, output for monitor unit PF2D 300/301 (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Pulse output Output Voltage output Note 5) 1 to 5 V Accuracy: 2% F.S., Min. load impedance: 100 k (Output impedance: 1 k) Analog specifications Current output Note

1 Made to Order Nil 1 3 5 Without cable 1.5 Nil D Screw mounting DIN rail mounting1 Nil X5 Standard product With magnet/switch rail 3 1 Only available for the controller types 6N and 6P 2 DIN rail is not included. Order it separately. 5 When Without controller is selected for controller types, I/O cable length cannot be selected.

Model HRS200-Am-46-mS Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.65 Control method PID control Ambient temperature/Altitude1, 7 C Temperature: 5 to 45, Altitude: less than 3000 m Circulating uid1, 2 Tap water, 15% Ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity3, 7 kW 20.5 Heating capacity4 kW

/min 612 V V gal/min 712 V gal/min Port size Symbol Port size Applicable model LFE1 LFE2 LFE3 3 3/8 V 4 1/2 V 6 3/4 V 8 1 V 1 Options 4, 5, 6, and 7, which are not in SI units, are not for use in Japan due to the New Measurement Law. 2 Options 4, 5, 6, and 7 cannot be selected when the output specication is J or K.

Air Operated Type Integral Fitting Type (Hyper Fittings) Series LVC How to Order Valves (Single Type) LVC LVA LVC 2 0 06 S LVH Option Body class Nil 1 2 3 4 None With flow rate adjustment With bypass With flow rate adjustment & bypass With indicator LVD Body class 2 3 4 5 6 Orifice dia. 4 8 10 16 22 Symbol 2 3 4 5 6 Valve type LQ2 integral fitting LVQ N.C. N.O.

LVN Material Body Diaphragm Note Actuator section End plate Symbol TL/TIL Applicable tubing size PFA PPS PTFE Nil Body class LQ3 Connecting tubing outside diameter Symbol Ammonium hydroxide compatible 2 1 3 4 5 PFA PPS PTFE N Metric sizes 03 04 06 08 10 12 19 3 4 6 8 10 12 19 Pilot port thread type Symbol Body class 1 2, 3, 4, 5 1, 2, 3, 4, 5 Thread type 4 One-touch fitting 6 One-touch fitting

N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6

Wiring (Output) Load voltage Auto switch model Lead wire length [m]2 Pre-wired connector Applicable load Electrical entry direction 0.5 (Nil) 1 (M) 3 (L) 5 (Z) DC AC Perpendicular In-line Indicator light Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire

Rotary Gripper Series MRHQ How to Order Lead wire length 0.5 m 3 m 5 m Nil L Z MRH 10 90 M9NV Q S M9N D Number of auto switches Rotary gripper Type of auto switch for detecting rotation Nil Without auto switch(Built-in magnet) 2 pcs. 1 pc.

Load voltage Auto switch model Lead wire length [m]1 Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V M9NWV M9NW