Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
However, as more than 40 years have elapsed since production started, we recommend switching to a VPA742-1-03*-F or VPA742-1-04*-F.
Note) The operating pressure range of VPA742 series valves is 0.2 to 1.0 MPa.
As for VSA4□20, VSA4□30, and VSA4□40 series valves, they are also still available and can be found in the web catalog.
Body Size: 3 (3/8 Basis), Body Material: 1 [ADC12 (Aluminum)], Thread: T (NPTF), Port Size: 03 [3/8 (15A): PA3]
Body Size: 3 (3/8 Basis), Body Material: 1 [ADC12 (Aluminum)], Thread: N (NPT), Port Size: 03 [3/8 (15A): PA3]
Assembly Environment: Ordinary Environment, Operation: 0 (Automatic Operation Type), Connection Size: 03 (Rc 3/8, Rc 1/4), Option: B (Foot)
Assembly Environment: Ordinary Environment, Operation: 3 (Air Operated Type), Connection Size: 03 (Rc 3/8, Rc 1/4), Option: B (Foot)
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: None, Specifications: 1 (0.005 to 0.2 MPa Setting)
Size: 30, Backflow Function: K (Backflow Function), Thread: Rc, Port Size: 03 (3/8), Accessory: H (Set Nut for Panel Mount)
Size: 40, Backflow Function: K (Backflow Function), Thread: F (G), Port Size: 03 (3/8), Accessory: None, Specifications: 3Y (3+Y)
Size: 40, Backflow Function: None, Thread: F (G), Port Size: 03 (3/8), Accessory: B (Bracket), Specifications: Y (Upward Facing Knob)
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: E (Square Embedded Pressure Gauge w/Limit Indicator)
Size: 40, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: E (Square Embedded Pressure Gauge w/Limit Indicator)
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: None, Specifications: R (Flow Direction: Right to Left)
Size: 30, Backflow Function: None, Thread: F (G), Port Size: 03 (3/8), Accessory: BE (B+E), Specifications: 3Y (3+Y)
Size: 40, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: None, Specifications: 3 (0.008 to 0.6 MPa Setting)