SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-M5-L"

Rated Flow Range: 5 to 500 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: -, Unit Specification: -, Option 2: -, Calibration Certificate: -

Cylinder Port: NPT, Arm Opening Angle: 90°, Arm Position: Right Side, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Plain ref NAAMS ACA001M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: G, Arm Opening Angle: 90°, Arm Position: Both Sides, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Machined ref NAAMS ACA007M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: NPT, Arm Opening Angle: 90°, Arm Position: Right Side, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Machined ref NAAMS ACA008M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: NPT, Arm Opening Angle: 135°, Arm Position: Right Side, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Machined ref NAAMS ACA010M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: G, Arm Opening Angle: 90°, Arm Position: Right Side, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Machined ref NAAMS ACA007M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: NPT, Arm Opening Angle: 105°, Arm Position: Both Sides, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Plain ref NAAMS ACA001M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Cylinder Port: NPT, Arm Opening Angle: 90°, Arm Position: Right Side, Switch Type: P & F, R Arm Mtg Position: Mounting Position A, R Arm Style: Straight Machined ref NAAMS ACA007M, L Arm Mtg Position: -, L Arm Style: -, Painted Arm: -

Model: 50 (Side Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 2 (Lateral), Wiring Specification: S (All Single Wiring), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides), A,B Port Size: N7 (ø1/4" One-touch Fitting, Fixed), Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EA, IT4000 3/8 INCPT VERSION, 2.32157 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EA, IT4000 3/8 INCPT VERSION, 1.42198 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 1.32277 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.86657 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 1.42198 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR 1/4 PF, EUROPEAN, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, D7, IT2000 1/4 INCEUROPEAN, 1.87392 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR W/GAUGE, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, .88184 lb