Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Type L One-touch connection Screw-in connection [L/min(ANR)] 1.
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2
P tight screw (4 x 14) , 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tight screw (4 x 14) , 2 pcs. (3) Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5) , 2 pcs.
S 100 L Flow control valve (With pressure compensation) Enables constant movement even if there are load fluctuations.