AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 1 LPM , 1 LPM, Max Pressure: 12 PSIG / 827 mbar , 12 PSIG / 827 mbar, Max Vacuum: 19.4 in HgV / -658 mbar , 19.4 in HgV / -658 mbar, Voltage (DC): 12, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Stations: 08, A,B Port: N7 (ø1/4" One-touch Fitting, Inch), Thread: T (NPTF)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Handle Position: B (Front), Piping: 3 (IN: Bottom/OUT: Top), Stations: 3 Stations, Fitting: 08 (IN: Straight Ø6, OUT: Straight Ø6), Accessory: A (Pressure Gauge), Option: None, Unit: Z [Name Plate, Gauge & Pressure Switch w/Unit Switching Function (PSI)]
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle Size
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)